The SYNCHRONOUS ON/OFF key is in addition to the individual
OUTPUT switches and permit both outputs to be turned on or off
synchronously with a single key press. Since this key turns both outputs
on or off with alternate presses it is necessary for both outputs to be in the
same state (i.e. both on or both off) before the key is used. Pressing the
key with one output on and one output off will have no effect.
It is possible to switch from V
TRACK
back to Independent with LOCK still set on the Master. The
Master settings stay ’locked’ but the settings of the Slave are not locked
.
The V
TRACK
status at power on is the same as at last power off.