VISCA Protocol 

(CONTD)

 

 

 

 

25 

 

 

 

 

Color adjust 

Flare red 

8x 01 04 B8 dat FF 

Flare mode red value (Default=32) 

Flare green 

8x 01 04 B9 dat FF 

Flare mode green value (Default=32) 

Flare blue 

8x 01 04 BA dat FF 

Flare mode blue value (Default=32) 

 

 

 

 

SYS_Menu 

Menu On 

8x 01 06 06 02 FF 

Turn on menu 

Menu Off 

8x 01 06 06 03 FF 

Turn off menu 

Menu Back 

8x 01 06 06 10 FF 

Menu step back 

 

Menu Ok 

 

8x 01 7E 01 02 00 01 FF 

 

Menu ok 

 

 

 

IR_Receive 

On 

8x 01 06 08 02 FF 

 

 

 

IR(remote commander)receive ON/OFF 

 

Off 

 

8x 01 06 08 03 FF 

On/Off 

8x 01 06 08 10 FF 

Cam_Tally 

RGB 

8x 01 7E 01 0A 00 0p FF 

P=0:    OFF 

P=1:    RED 

P=2:    GREEN 

P=3:    RED&GREEN 

P=4:    BLUE  

P=5:    RED&BLUE 

P=6:    GREEN&BLUE 

P=7: RED&GREEN&BLUE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pan_TiltDrive 

 

Up 

 

8x 01 06 01 VV WW 03 01 FF 

 

 

 

 

 

 

 

 

 

 

VV: Pan speed 0x01 (low speed) to 
0x18 (high speed) 

 

WW: Tilt speed 0x01 (low speed) to 
0x14 (high speed) 

 

YYYY: Pan Position(TBD) 

ZZZZ: Tilt Position(TBD) 

Down 

8x 01 06 01 VV WW 03 02 FF 

Left 

8x 01 06 01 VV WW 01 03 FF 

Right 

8x 01 06 01 VV WW 02 03 FF 

 

Upleft 

 

8x 01 06 01 VV WW 01 01 FF 

Upright 

8x 01 06 01 VV WW 02 01 FF 

 

Downleft 

 

8x 01 06 01 VV WW 01 02 FF 

 

Downright 

 

8x 01 06 01 VV WW 02 02 FF 

 

Stop 

 

8x 01 06 01 VV WW 03 03 FF 

 

Absolute Position 

8x 01 06 02 VV WW 0Y 0Y 0Y 0Y 0Z 

0Z 0Z 0Z FF 

 

Relative Position 

8x 01 06 03 VV WW 0Y 0Y 0Y 0Y 

0Z 0Z 0Z 0Z FF 

 

Home 

 

8x 01 06 04 FF 

Reset 

8x 01 06 05 FF 

 

 

Pan Tilt_LimitSet 

 

Set 

8x 01 06 07 00 0W 

0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF 

PW: 1: UpRight 0:DownLeft 
YYYY: Pan Limit Position(TBD) 
ZZZZ: Tilt Limit Position(TBD) 

 

Clear 

8x 01 06 07 01 0W 

07 0F 0F 0F 07 0F 0F 0F FF 

Содержание PTZ4K-NDI-X12

Страница 1: ...Ultra HD 12x Optical Zoom PTZ PTZ4K NDI X12 User Manual V1 0 AIDA...

Страница 2: ...mera Interface Dimension 7 IR Remote Controller 9 OSD Menu 12 Web Settings 18 VISCA Over IP 19 VISCA RS 232 Port 20 VISCA Protocol 29 UVC Control 30 Warranty Support The information within this manual...

Страница 3: ...ring transportation storage or operation 7 Do not remove the camera housing or cover Any attempt to self repair or open the camera will void all warranty 8 Make sure the camera is on a fixed and balan...

Страница 4: ...PTZ Camera Power Adapter Power Cable RS232 Control Cable USB Type C Cable RemoteControl User Manual DoubleSidedAdhesive QCCertification WallMount 1 Please ensure all the cabling is correct PTZ Outputs...

Страница 5: ...Updating Mode 2 ON OFF Debugging Mode 3 OFF ON Undefined 4 ON ON Working Mode Dial Switch SW 3 SW 4 Instruction 1 OFF OFF Reserve 2 ON OFF Reserve 3 OFF ON Reserve 4 ON ON Reserve Dial Switch USB SW...

Страница 6: ...TZ movements for sound sensitive rooms Supports up to 10 presets via the remote or 128 presets via RS232 web UI Supports Sony Serial Visca and VISCA over IP Also supports NDI control Supports in and o...

Страница 7: ...5 NDI HX Network Speed 1000M Video Encode H 264 H 265 default H 264 Bit Rate Control Variable Bit Rate Constant Bit Rate Video Bit Rate 1024kbps min 61440 kbps max IP Protocol RTSP RTMP 0NVIF VISCA ov...

Страница 8: ...s 6 tripod mounting hole 11 USB Type C 2 Camera Base 7 WM Installation Holes 12 HDMI Output 3 IR receiver panel 8 RS 232 Control Input 13 RJ 45 NDI HX Port 4 Power Tally Indicator 9 RS 232 Control Out...

Страница 9: ...sed when operating multiple PTZ s in same line of sight SET 1 4 Address Setting Hold the SET button to set the cameras IR address CAM 1 4 Buttons Pressing the CAM button will enable the IR control of...

Страница 10: ...e pan tilt threshold by pressing the LIMIT L and LEARN button to set the Left LIMIT L or Right LIMIT R threshold You can use LIMIT CLR to reset this SCAN Currently has no function Video Format Keys Bl...

Страница 11: ...vement freeze the image for smooth transitions SDI HDMI only DEFAULT OFF PRESET SPEED Adjust the speed at which it will take to get to the next preset DEFAULT 18 PRESET SAVE AE AW Optional OFF ON Defa...

Страница 12: ...menu QUALITY 2DNR When enabled image noise and sharpness is reduced DEFAULT OFF 3DNR OFF AUTO 0 4 optional higher level less image reduction happens DEFAULT AUTO SHARPNESS ON OFF optional 0 15 level...

Страница 13: ...rent main stream RTSP URL F W VERSION Display the current ISP firmware version ARM VERSION Display the current ARM firmware version RELEASE Software release date RESET FACTORY RESET Reset whole camera...

Страница 14: ...ewing When logging in you will get a real time image preview of the camera via our HTTP protocol On the right is the control interface You can control the camera s movements with the directional butto...

Страница 15: ...the encoding profile mode for the camera MP Main Profile Used for web streaming Baseline Baseline Profile Used for streaming to legacy devices HP High Profile Use for recording purposes with other so...

Страница 16: ...ook something like the found on the page 3 Place the live RTMP address in the RTMP address slot 4 Next ensure there is a forward slash after the RTMP address 5 Lastly paste the stream key if necessary...

Страница 17: ...tion is selected choose the keylength of the password Passphrase Enter the encryption password for the software to connect to the camera Main Stream Sub Stream Will populate once complete Caller mode...

Страница 18: ...r cycle the camera after clicking save DHCP OFF DNS 192 168 1 1 IP Address 192 168 1 188 HTTP Port 80 Netmask 255 255 255 0 RTSP Port 554 Gateway 192 168 1 1 VISCA over IP 52381 Use the RTSP Encrypt o...

Страница 19: ...can change the account name and password from the default If you lose your new account password you will have to contact AIDA support for help so don t forget to write it down System Time In the syst...

Страница 20: ...PTZ cameras These VISCA commands are sent via UDP protocol Since UDP transmission isn t stable a couple of steps must occur before a movement is executed First the controller will send out a VISCA com...

Страница 21: ...6 NC 7 IR OUT 7 NC 8 B 8 NC Serial Port Configuration VISCA IN DB9 Connection Camera VISCA IN Windows DB9 1 DTR 6 DSR 2 DSR 4 DTR 3 TXD 2 RXD 4 GND 5 GND 5 RXD 3 TXD 6 A 7 IR OUT 8 B Parameter Value B...

Страница 22: ...e to current conditions For example when commands controlling the focus manually are received during auto focus Part 2 Camera Control Command AddressSet Broadcast 88 30 01 FF Address setting IF_Clear...

Страница 23: ...anual Focus 81 01 04 38 03 FF One Push AF 8x 01 04 18 01 FF CAM_ZoomFocus Direct 8x 01 04 47 0p 0q 0r 0s 0t 0u 0v 0w FF pqrs Zoom Position 0 wide 0x4000 tele tuvw Focus Position CAM_WB Auto 8x 01 04 3...

Страница 24: ...Iris Position 0 0x0D CAM_Gain Reset 8x 01 04 0C 00 FF Gain Setting 0 0x0E Up 8x 01 04 0C 02 FF Down 8x 01 04 0C 03 FF Direct 8x 01 04 0C 00 00 0p 0q FF pq Gain Position 0 0x0E CAM_Bright Reset 8x 01 0...

Страница 25: ...oomSpeed Zoom Speed 8x 01 04 D1 00 00 0p 0q FF pq Zoom Speed 0x01 0x07 CAM_ZoomDisplay On 8x 01 06 C2 02 FF Off 8x 01 06 C2 03 FF CAM_Freeze Freeze 8x 01 04 75 0p FF p Freeze switch 3 OFF 2 ON CAM_Pre...

Страница 26: ...n Main Stream Resolution 8x 01 04 C2 00 0p 0q 0r 0s 0m 0n 0x 0y FF pqrs Column x size mnxy Line y size only support 3840x2160 1920x1080 1280x720 1024x576 Rate 8x 01 04 C2 01 0p 0q 0r 0s 0m 0n 0x 0y FF...

Страница 27: ...D GREEN BLUE Pan_TiltDrive Up 8x 01 06 01 VV WW 03 01 FF VV Pan speed 0x01 low speed to 0x18 high speed WW Tilt speed 0x01 low speed to 0x14 high speed YYYY Pan Position TBD ZZZZ Tilt Position TBD Dow...

Страница 28: ...x 09 04 39 FF y0 50 00 FF Full Auto y0 50 03 FF Manual y0 50 0A FF Shutter Priority y0 50 0B FF Iris Priority y0 50 0D FF Bright CAM_Shutter PosInq 8x 09 04 4A FF y0 50 00 00 0p 0q FF pq Shutter Posit...

Страница 29: ...50 0p 0q 0r 0s FF pqrs Camera ID CAM_DHCPInq 8x 09 04 AE FF y0 50 pp FF CAM_IPInq 8x 09 04 AB FF y0 50 0p 0p 0q 0q 0r 0r 0s 0s FF CAM_MASKInq 8x 09 04 AC FF y0 50 0p 0p 0q 0q 0r 0r 0s 0s FF CAM_GATEW...

Страница 30: ...rate 1024 16384 Substream ResolutionInq 8x 09 04 C3 00 FF y0 50 0p 0q 0r 0s 0m 0n 0x 0y FF pqrs Column x size mnxy Line y size only supports 1280x720 1024x576 640x360 SubstreamRateInq 8x 09 04 C3 01 F...

Страница 31: ...0 0p 0q FF PU_GAMMA_CONTROL 8x 01 04 5B 0p FF PU_WHITE_BALANCE_TEMPERATURE_CONTROL 8x 01 04 35 0X FF PU_BLACKLIGHT_COMPENSATION_CONTROL 81 01 04 33 02 03 FF PU_POWER_LINE_FREQUENCY_CONTROL 8x 01 04 AA...

Страница 32: ...rranty Support If you would like additional support or explanation on anything related to our product please feel free to our website at aidaimaging com support for more info We have Youtube tutorials...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...AIDA IMAGING 1278 Center Court Dr Covina CA 91790 Tel 909 333 7421 support aidaimaging com www aidaimaging com...

Отзывы: