background image

 

 

 

 

TB101-HA 

NEBS/Telco Ready Barebone 

User Manual 

 

 

 

 

 

 

 

 

 

 

              

              

P/N:

 

H881BD0W41-00000-0 

Document Number: MAN-00107-A

 

 

Содержание TB101-HA

Страница 1: ...TB101 HA NEBS Telco Ready Barebone User Manual P N H881BD0W41 00000 0 Document Number MAN 00107 A...

Страница 2: ...Front View of TB101 HA 8 1 4 Rear View of TB101 HA 8 1 5 Top View of TB101 HA 9 Chapter 2 Hardware Setup 10 2 1 Chassis Cover 10 2 2 System Memory 13 2 3 Drive Bays 15 2 4 Riser Card 17 2 5 Expansion...

Страница 3: ...od 1 Use the BIOS setup 29 5 2 Method 2 Use a Dos tool Syscheck 31 5 3 Connect to BMC 33 5 4 Updating BMC Firmware 36 Chapter 6 Technical Support 37 Copyright 2012 AIC Inc All Rights Reserved This doc...

Страница 4: ...such as a wet faucet Never push objects of any kind into this product through open slots as they may touch dangerous voltage points or short out parts that could result in fire or electric shock Never...

Страница 5: ...ser Manual This document provides a detailed description of the TB101 HA including General Features of the Product Hardware Setup Motherboard Settings BIOS Configuration and Settings BMC Configuration...

Страница 6: ...orage applications TB101 HA harnesses MAX I O technology to maximize the usage of off the shelf expansion cards in the barebone System Package Contents Check your package for the following items Mothe...

Страница 7: ...pport Dual LGA1356 Socket B2 to support 2 x Intel Xeon processor E5 2400 series Sandy Bridge EN QPI Speeds 8 GT s 7 2 GT s 6 4 GT s Chipset Chipset Support Intel C600 series chipset System Memory Syst...

Страница 8: ...Port 1 x DB 9 serial port Power Supply Power Supply Option AC DC 650W 1 1 redundant power supply 90 264VAC 47 63 Hz 80 Gold or Standard System Cooling System Cooling 4 x 40mmx56mm hot swap fans redund...

Страница 9: ...Off Alert LED Red Light System Alert System Reset Push for System Reset LAN LED Green Light Link Blink Activity NMI Non maskable interrupt Push for the highest priority interrupt in the system HDD LE...

Страница 10: ...View of TB101 HA The barebone server includes the basic components shown as below 4 Hot Swap Redundant fans fa Hot swap HDD Trays AC DC650W 1 1 Hot Swap Redundant PSU Hadar MB Expansion Slot Rear IO...

Страница 11: ...lacing a defective part once the TB101 HA appliance is installed and is operational 2 1 Chassis Cover 2 1 1 Removing the Chassis Cover 1 Release screws from the upper panel and rear panel 2 Pull the c...

Страница 12: ...load lever to release the load plate 2 Lift the load plate 3 Remove the processor protective cover from CPU socket 4 Align the processor cutouts against the socket notches 5 C l o s e Processor protec...

Страница 13: ...sink 1 Position the heatsink on the CPU and fasten the four screws attaching the heatsink to the motherboard 2 Tighten the four screws in a diagonal sequence a couple of turns at a time until all four...

Страница 14: ...Populate DIMMs in the following order DIMM Numbers DIMM arrangement 2 DIMMs CH0 CH1 CH2 CPU0 DIMM 0 CPU1 DIMM 0 4 DIMMs CH0 CH1 CH2 CPU0 DIMM 0 CPU1 DIMM 0 CPU0 DIMM 0 CPU1 DIMM 0 6 DIMMs CH0 CH1 CH2...

Страница 15: ...M 0 CPU1 DIMM 0 CPU0 DIMM 0 DIMM 1 CPU1 DIMM 0 DIMM 1 CPU0 DIMM 0 DIMM 1 CPU1 DIMM 0 DIMM 1 12 DIMMs CH0 CH1 CH2 CPU0 DIMM 0 DIMM 1 CPU1 DIMM 0 DIMM 1 CPU0 DIMM 0 DIMM 1 CPU1 DIMM 0 DIMM 1 CPU0 DIMM 0...

Страница 16: ...e the front cover by releasing two screws from each side 2 Release a drive tray by pushing the release button to open the latch 3 Firmly hold the tray latch and pull the drive out of the drive slot 4...

Страница 17: ...lot until it is fully seated Make sure the drive tray is correctly secured in place when its front edge aligns with the bay edge Close the latch until it clicks to lock the drive 6 Repeat steps from1...

Страница 18: ...DE DESCRIPTION PSG RC HA1U 40 101 PSG Code PE1U16 Max IO supports 1 x PCIe X16 2 x PCIe X8 1 x PCIe X4 RISER CARD DIAGRAM Top view Add on card side Buttom view side Slot Bandwidth PCIE 4 PCIE 16X X8 P...

Страница 19: ...1 Installing an External Expansion Card to the Riser Card 1 Remove two screws to release the bracket 2 Install the expansion card on the proper slot and connect it to the riser card Secure the bracket...

Страница 20: ...firmly and pull the fan out of the server chassis to remove the fan module from the server chassis 2 7 Power Supply 2 7 1 Removing or Replacing the Power Supply Module 1 Release two thumb screws from...

Страница 21: ...ation 1 VGA Port D SUB15 J1 13 Front IO J15 2 COM Port D SUB 9 J2 14 Inactive Power OK J17 3 USB Port x 2 J3 15 PC Buzzer J18 4 BMC debug Port J4 16 ME Mode J19 5 VGA 8 x 2 pin Header J5 17 PC Debug P...

Страница 22: ...C 11 AVSYNCO 13 GND 15 GND 2 DACROA 4 NC 6 GND 8 DACBOA 10 AHSYNCO 12 DVO_5V 14 GND 16 DDC_CLKO J8 Disable BMC Jumper Default NC J9 UART COM2 1 DSRB 3 RTSB 5 CTSB 7 RIB 9 NC 2 DCDB 4 RXDB 6 TXDB 8 DTR...

Страница 23: ...N2_TACH A17 HW_FAN3_TACH A18 HW_FAN4_TACH A19 GND A20 I2C5SCL A21 I2C5SDA A22 PSU_SMBUS A23 PSU_SMBUS A24 I2C1SCL A25 I2C1_SDA B1 PWR_BTN B2 RST_BTN B3 NMI_BTN B4 UID_BTN B5 3 3V_DUAL B6 3 3V B7 HEALT...

Страница 24: ...PC_LFRAME 6 RST_PLTRST_N 8 ICH_LPC_LAD3 10 3 3V 12 ICH_LPC_LAD0 J21 Clear CMOS Jumper 1 P3V3_VBAT 2 RST_RTCRST 3 GND Default 1 2 close J41 Power Supply 1 GND 2 GND 3 GND 4 GND 5 12V 6 12V 7 12V 8 12V...

Страница 25: ...ower Left Status LED 1G Orange 100M Green 10M No connect Off 2 Internal LED Definition LED Status Description UID LED LED1 On Blinking UID activity detected Off UID not activity detected LAN i350 Powe...

Страница 26: ...25 Chapter 4 BIOS Configuration and Settings 4 1 BIOS Setting 1 Press DEL to run the setup procedure 2 There will be a message Entering SETUP displayed on the diagnostics screen...

Страница 27: ...26 3 Identify the BIOS Version 4 Load Optimal Default setting 5 Save the setting and exit BIOS setup utility...

Страница 28: ...y during POST 1 Prepare a USB mass storage device 2 Put BIOS bin file and mflash cfg in Root directory 3 Plug the USB mass storage device into a USB port of the target computer 4 Turn on system 5 Boot...

Страница 29: ...ity To use this utility you must include the flash bat AICFLASH EXE AFUDOS exe and bin file in the same folder Please follow the instructions to update whole flash part 1 Insert boot media which has f...

Страница 30: ...Settings Insert Ethernet LAN cable into the BMC LAN port There are two methods to setup BMC IP 5 1 Method 1 Use the BIOS setup 1 BIOS SETUP Server Mgmt BMC network configuration Configuration Address...

Страница 31: ...30 2 Input IP address Set static IP 3 Input subnet mask address...

Страница 32: ...31 5 2 Method 2 Use a Dos tool Syscheck 1 Type sc lanset 2 Modify IP setting 3 Input IP address...

Страница 33: ...32 4 Input submask address Below IP address is an example using a default IP setting User is allowed to change the IP address for realistic use 5 Finish BMC IP configuration...

Страница 34: ...default IP setting User is allowed to change the IP address for realistic use 1 Open the browser then type default BMC IP address 192 168 22 22 2 Use the default user name and password for first time...

Страница 35: ...34 3 Information of firmware 4 Server Health Sensor Readings 5 Configuration Please refer to AIC BMC User Guide for more information on AIC BMC...

Страница 36: ...35 Mouse Mode setting For Windows OS environment set mode to absolute For Linux OS environment set mode to relative 6 Remote Control Environmental setting...

Страница 37: ...ectory XXXXXZYY XXXXX project name YY firmware version Z Identify character C for official B for Beta 3 Execute a bat batch file to update the BMC firmware Example A cd SB301C01 A SB301C01 a bat This...

Страница 38: ...m CHINA Tel 021 54961421 021 54961422 Fax Extension 608 Email Technical Support support aicipc com AMERICA West coast Tel 1 909 895 8989 Fax 1 909 895 8999 Email Technical Support support aicipc com A...

Страница 39: ...38 Note...