27
J65
VOLTAGE TEST
POINT GROUP A
1
2
15
16
1.+1.5V_DDR3_CPU0 2.GND
3.VCCP_CPU0 4.GND
5.VTT_CPU0 6.GND
7.+3.3V 8.GND
9.+3.3V_DUAL 10.GND
11.+5V 12.GND
13.+1.5V 14.GND
14.GND 16.GND
J67
BMC GPIO
1
2
5
6
1.GND 2.NC
3.GPIOE7 4.GPIOB7
5.GPIOE6 6.GPIOB2
3.2.4 Internal LEDs
J20
LAN LED
1
2
1 3
1 4
LED ON=LAN LINK
LED BLINK=ACTIVE
1.GbE5 LED# 2.GbE5 LED+
3.GbE4 LED# 4.GbE4 LED+
5.GbE3 LED# 6.GbE3 LED+
7.GbE2 LED# 8.GbE2 LED+
9.NC 10.3.3V
11.GbE1 LED# 12.GbE1 LED+
13.GbE0 LED# 14.GbE0 LED+
J28
FRONT PANEL
1
2
19
20
1.PWR LED+ 2.PWR BTN
3.PWR LED# 4.GND
5.HDD LED+ 6.RST BTN
7.HDD LED# 8.GND
9.SYS ID LED+ 10.FP ID BTN
11.SYS ID LED# 12.GND
13.SYS FLT LED+ 14.FP NMI BTN
15.SYS FLT LED# 16.GND
17.SB SMB DATA 18.5VSB
19.SB SMB CLK 20.GND
D22
DEBUG PORT
DEBUG PORT is used by the BIOS to indicate a
serious or fatal error to the end user. DEBUG PORT
is used when an error occurs before the system
video has been initialized.
Содержание SB303-GE
Страница 1: ...SB303 GE Storage Server Barebone User Manual Document Number MAN 00106 A...
Страница 13: ...12 4 Align the processor cutouts against the socket notches 5 Close the load plate load lever...
Страница 33: ...32 2 Input IP address Set IP static 3 Input subnet mask address...
Страница 34: ...33 5 2 Method 2 Use a Dos tool Syscheck 1 Type sc lanset 2 Modify IP setting...
Страница 42: ...41 Note...