SB303-GE 

Storage Server Barebone 

User Manual 

 

 

 

              

              

 

 

Document Number: MAN-00106-A 

 

Содержание SB303-GE

Страница 1: ...SB303 GE Storage Server Barebone User Manual Document Number MAN 00106 A...

Страница 2: ...al Processing Unit CPU 11 2 2 1 Installing the CPU 11 2 2 2 Installing the CPU Heatsink 13 2 3 System Memory 14 2 4 Drive Bays 16 2 4 1 Installing or Replacing 3 5 Hot swap SAS SATA HDD 16 2 4 2 Insta...

Страница 3: ...onnectors Continue 27 3 2 4 Internal LEDs 28 Chapter 4 BIOS Configuration and Settings 29 4 1 BIOS Setting 29 4 2 Updating BIOS 31 Chapter 5 BMC Configuration and Settings 32 5 1 Method 1 Use the BIOS...

Страница 4: ...ce such as a wet faucet Never push objects of any kind into this product through open slots as they may touch dangerous voltage points or short out parts that could result in fire or electric shock Ne...

Страница 5: ...s Manual This document provides a detailed description of the SB303 GE including The General Features of the Product Hardware Setup Motherboard Settings BIOS Configuration and Settings BMC Configurat...

Страница 6: ...imizing the usage of off the shelf expansion cards up to 10 in the barebone System Package Contents Check your package for the following items Motherboard Gemini Components 2x 1000W 1 1 Hot swap Redun...

Страница 7: ...ory recommended Unbuffered ECC SDRAM Tri channel 2 DIMMs per channel Front Panel Controls Power ON OFF NMI button System ID 1 x USB System Reset System Drive activity LEDs Power LEDs System ID 6 x Gre...

Страница 8: ...mory 1600 x 1200 60 Hz Super I O Winbond W83627DHG Rear I O LAN 6 six x one gigabit Gb Ethernet connectors 1 one x 10 Gb Ethernet port USB 2 two x USB ports VGA 1 one x VGA port Serial Port 1 one x DB...

Страница 9: ...er ON OFF Push for Power On or Off System ID LED Blue System Identification Blink Activity System ID Push for ID LED On or Off Alert LED Red Light System Alert System Reset Push for System Reset LAN L...

Страница 10: ...View of SB303GE The barebone server includes the basic components shown below Hot swap HDD Trays Gemini Motherboard Power Supply Full Length Expansion Card Bracket Full Length Expansion Card Bracket...

Страница 11: ...Setup This section SB303 GE appliance is installed and is operational 2 1 Chassis Cover 2 1 1 Removing the Chassis Cover 1 Release the two screws on the rear panel 2 Pull the cover back to open the re...

Страница 12: ...11 2 2 Central Processing Unit CPU 2 2 1 Installing the CPU 1 Press the load lever to release the load plate 2 Lift the load plate 3 Remove the processor protective cover from CPU socket...

Страница 13: ...12 4 Align the processor cutouts against the socket notches 5 Close the load plate load lever...

Страница 14: ...Place the heatsink on top of the CPU ensuring that the four fasteners match the holes on the motherboard 2 Tighten the four screws in a diagonal sequence a couple of turns at a time until all four scr...

Страница 15: ...ommended Unbuffered ECC SDRAM 1 Populate DIMMs in the following order DIMM Numbers DIMM arrangement 2 DIMMs CH0 CH1 CH2 CPU0 DIMM 0 CPU1 DIMM 0 4 DIMMs CH0 CH1 CH2 CPU0 DIMM 0 CPU1 DIMM 0 CPU0 DIMM 0...

Страница 16: ...IMM 0 CPU0 DIMM 0 DIMM 1 CPU1 DIMM 0 DIMM 1 CPU0 DIMM 0 DIMM 1 CPU1 DIMM 0 DIMM 1 12 DIMMs CH0 CH1 CH2 CPU0 DIMM 0 DIMM 1 CPU1 DIMM 0 DIMM 1 CPU0 DIMM 0 DIMM 1 CPU1 DIMM 0 DIMM 1 CPU0 DIMM 0 DIMM 1 CP...

Страница 17: ...ray 2 Firmly hold the tray lever and pull the drive out of the bay 3 Place the 3 5 HDD on the tray and then secure it with four screws from the both sides of HDD tray 4 Insert the drive carrier into i...

Страница 18: ...y and pulling out the drive tray 2 Firmly hold the tray lever and pull the drive out of the bay 3 Place the 2 5 HDD on the tray and then secure it with four screws on the bottom 4 Insert the drive car...

Страница 19: ...ews on the right side of rear panel 2 Remove the screws on the bottom of barebone 3 Remove the power housing screws on the left side of rear panel 4 Release the screw on the fan bracket then firmly ho...

Страница 20: ...PTION PSG RC GEHO 70 212 PE3U01 Gemini 3U Gold finger PCIe Gen2 X16 to 2 PCIe X16 3 PCIe X8 1 X8 Gen2 1 X4 Gen2 1 X4 Gen1 RISER CARD DIAGRAM Front view Rear View Slot Bandwidth PCIE1 X16 GEN2 PCIE3 X8...

Страница 21: ...PEE PEF PEG PEH PEI SW2 OFF OFF ON ON OFF OFF X 16 x 4 x 4 x 8 x 8 2 7 Expansion Slot 2 7 1 Installing an External Expansion Card to the Riser Card 1 Remove the screw to release the bracket To instal...

Страница 22: ...ng an External PCIE Card to the Riser Card 1 Remove the screw to release the bracket To install a full length expansion card please remove the half length bracket 2 Insert the full length PCIE card 3...

Страница 23: ...fan lever firmly and pull the fan out of the server chassis to remove the fan module from the server chassis 2 9 Power Supply 2 9 1 Removing or Replacing the Power Supply Module 1 Release the two thum...

Страница 24: ...BOARD CONNECTOR J63 3 CPU1 JTAG BYPASS J41 8 VGA HEADER J6 4 CPU0 VRM TEST J12 9 KB MS J3 5 CPU1 VRM TEST J19 10 UART COM2 J4 6 VGA DISABLE J26 11 USB J25 7 AST ARM J13 12 GPIO J29 8 AST ARM RESET J5...

Страница 25: ...ASS 1 3 1 2 JTAG BY PASS 2 3 NORMAL J12 J19 CPU0 CPU1 VRM TEST 1 2 1 2 ENABLE OFF NORMAL J26 VGA DISABLE 1 2 1 2 DISABLE OFF ENABLE J13 AST ARM 1 2 1 2 DISABLE OFF ENABLE J5 AST ARM RESET 1 2 1 2 RESE...

Страница 26: ...PWM4 12 FAN4_TACH 13 FAN6_TACH 14 FAN5_TACH 15 GND 16 GND J21 SIO FAN CONN UP 1 FAN7_TACH 2 FAN8_TACH 3 FAN1_TACH 4 PWM1 5 FAN2_TACH 6 PWM2 7 FAN3_TACH 8 PWM3 11 GNDc 12 GND J62 SIO FAN CONN DOWN 1 2...

Страница 27: ...KB_CLK 4 MS_CLK 5 MS_DATA 6 GND J4 UART COM2 1 DSR 2 DCD G 3 RTS 4 RXD 5 CTS 6 TXD 7 RI 8 DTR 9 NC 10 GND J18 PSU12C 1 4 1 5V_AUX 2 I2C_CLK 3 I2C_DATA 4 GND J17 IPMB 12C 1 4 1 I2C_DATA 2 GND 3 I2C_CL...

Страница 28: ...4 LED 4 GbE4 LED 5 GbE3 LED 6 GbE3 LED 7 GbE2 LED 8 GbE2 LED 9 NC 10 3 3V 11 GbE1 LED 12 GbE1 LED 13 GbE0 LED 14 GbE0 LED J28 FRONT PANEL 1 2 19 20 1 PWR LED 2 PWR BTN 3 PWR LED 4 GND 5 HDD LED 6 RST...

Страница 29: ...28 Chapter 4 BIOS Configuration and Settings 4 1 BIOS Setting 1 Press DEL to run the setup procedure 2 There will be a message Entering SETUP displayed on the diagnostics screen...

Страница 30: ...29 3 Identify the BIOS Version 4 Load Optimal Default setting 5 Save the setting and exit the BIOS setup utility...

Страница 31: ...OS is a BIOS update utility with command line interface that works in DOS environment 2 The latest BIOS version is available from the FAE or AIC website 3 Enter flash at the DOS command line 4 Reboot...

Страница 32: ...er 5 BMC Configuration and Settings Insert BMC IP LAN into the BMC LAN port There are two methods to setup BMC IP 5 1 Method 1 Use the BIOS setup 1 BIOS SETUP Advance IPMI configuration Set LAN config...

Страница 33: ...32 2 Input IP address Set IP static 3 Input subnet mask address...

Страница 34: ...33 5 2 Method 2 Use a Dos tool Syscheck 1 Type sc lanset 2 Modify IP setting...

Страница 35: ...34 3 Input IP address 4 Input submask address Below IP address is an example using a default IP setting User is allowed to change the IP address for realistic use 5 Finish BMC IP configuration...

Страница 36: ...efault IP setting User is allowed to change the IP address for realistic use 1 Open the browser then type default BMC IP address 192 168 22 22 2 Use the default user name and password for first time l...

Страница 37: ...36 3 Information of ASTER firmware 4 Server Health Sensor Readings 5 Configuration Please refer to AIC BMC User Guide for more information on AIC BMC...

Страница 38: ...37 Mouse Mode setting For Windows OS environment set mode to absolute For Linux OS environment set mode to relative 6 Remote Control Environmental setting...

Страница 39: ...e 2 Enter BMC firmware directory XXXXNYYY XXXX M B name YYY firmware version 3 Execute a bat batch file to update the BMC firmware Example A cd AQUAN120 A AQUAN120 a bat This is just an example The la...

Страница 40: ...XXZYY XXXXX barbone name YY config version 3 Execute the config bat batch file to update config file Example A cd G107NC01 A G107NC01 config bat This is just an example the latest BMC configuration ve...

Страница 41: ...aicipc com CHINA Tel 021 54961421 021 54961422 Fax Extension 608 Email Technical Support support aicipc com AMERICA West coast Tel 1 909 895 8989 Fax 1 909 895 8999 Email Technical Support support ai...