background image

SB212-PH

Storage Server Barebone
User's Manual

UM_SB212-PH_v 2_052918

Содержание SB212-PH

Страница 1: ...SB212 PH Storage Server Barebone User s Manual UM_SB212 PH_v 2_052918...

Страница 2: ...the Fan Module 22 2 6 Removing and Installing the Power Supply Unit Module 23 2 7 Removing and Installing the PCIe support bracket 24 2 8 Replacing the PCIe Card and Riser Assembly 25 2 9 Replacing th...

Страница 3: ...pter 5 BMC Configuration Settings 51 5 1 Method 1 Use the BIOS Setup 51 5 2 Method 2 Use a Dos Tool Syscheck 54 5 3 Connect to BMC 56 5 4 Updating BMC Firmware 61 Chapter 6 Technical Support 62 conten...

Страница 4: ...Copyright 2017 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Страница 5: ...eption It is essential that only the supplied power cord be used 2 Use only shielded cables to connect I O devices to this equipment 3 You are cautioned that changes or modifications not expressly app...

Страница 6: ...unit chassis for a few seconds This will help to discharge any static electricity on your body Place this equipment on a stable surface when install A drop or fall could cause injury Please keep this...

Страница 7: ...ipment 3 The equipment has been exposed to moisture 4 The equipment does not work well or will not work according to its user manual 5 The equipment has been dropped and or damaged 6 The equipment has...

Страница 8: ...apter 5 BIOS Configuration Settings This chapter introduces the key features of BIOS including the descriptions and option keys for discrete functions These details provide users to maintain and confi...

Страница 9: ...e carton are damaged If any damage is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and...

Страница 10: ...ots PCIe 3 0 1 x16 1 x8 Riser Card included PSG RC PH1U 2N 110 x16 1 PCIe x8 and 10 PCIe x4 SFF 8643 for NVMe System BIOS BIOS Type FLASH Interface BIOS Features Rear I O LAN 2 x 10GbE SFP 2 x RJ45 US...

Страница 11: ...ddition to the noteworthy features of the barebone SB212 PH provides imme diate and efficient management with Onboard Baseboard Management Controller and greater I O extension Featuring IPMI 2 0 and A...

Страница 12: ...4 SB212 PH User s Manual Chapter 1 Product Features Front Panel 12 x 3 5 hotswap HDD trays 1 x USB3 0 port...

Страница 13: ...hapter 1 Product Features SB212 PH User s Manual Rear Panel AC 800W 1 1 redundant high efficiency power supply 80 2 x 10 GbE SFP External 2 5 hot swap x 2 2 x USB 3 0 Type A 2 x 1GbE RJ45 Serial Port...

Страница 14: ...ter 1 Product Features Major Components AC 800W 1 1 redundant power supply 80 AC 800W 1 1 redundant power supply 80 AC 800W 1 1 redundant power supply 80 AIC Server Board Phoenix AIC Server Board Phoe...

Страница 15: ...t with screw 1 and loosen it by giving it two rotations and stop see letter A 1b Proceed to screw 2 and loosen it by giving it two rotations and stop see letter B Similarly loosen screws 3 and 4 Repea...

Страница 16: ...P R O C E S S O R B E F O R E R E M O V I N G C O V E R S A V E A N D R E P L A C E C O V E R I F P R O C E S S O R I S R E M O V E D A R E M O V E R E M O V E L G A 2 0 1 1 3 S U P P L I E R I D E N...

Страница 17: ...inappropriate for your server CAUTION ESD and handling processors Reduce the risk of electrostatic discharge ESD damage to the processor by doing the following 1 Touch the metal chassis before touchi...

Страница 18: ...r see letter C Carefully place Do NOT drop the CPU into the socket CAUTION The pins inside the CPU socket are extremely sensitive Other than the CPU no object should make contact with the pins inside...

Страница 19: ...er A Slide the tip of the lever under the notch in the load plate see letter B Make sure the load plate tab engages under the socket lever when fully closed 4b Repeat the steps to latch the locking le...

Страница 20: ...s screwdriver start with screw 1 and engage screw threads by giving it two rotations and stop see letter C Do not fully tighten 5c 2 Proceed to screw 2 and engage screw threads by giving it two rotati...

Страница 21: ...CPU0 and CPU1 and align the heatsink screws with the screw holes in the motherboard Caution Possible thermal damage Avoid moving the heatsink after it has contacted the top of the CPU Too much movemen...

Страница 22: ...CPU0 and CPU1 and align the heatsink screws with the screw holes in the motherboard Caution Possible thermal damage Avoid moving the heatsink after it has contacted the top of the CPU Too much movemen...

Страница 23: ...15 Chapter 2 Hardware Setup SB212 PH User s Manual 2 2 System Memory This server board supports up to twelve DDR4 1333 1600 1866 2133 Registered ECC SDRAM RDIMM Load Reduced DIMM LRDIMM...

Страница 24: ...1 CPU0 DIMM Numbers DIMM ARRANGMENT 2 DIMMs CPU1 CPU0 JDIMM_G0 JDIMM_A0 JDIMMF0 JDIMMD0 JDIMMC0 JDIMME0 JDIMMG0 JDIMMG1 JDIMMH0 JDIMMH1 JDIMMA0 JDIMMA1 JDIMMB0 JDIMMB1 CPU0 CPU1 4 DIMMs CPU1 CPU0 JDIM...

Страница 25: ...U0 CPU1 JDIMMF0 JDIMMD0 JDIMMC0 JDIMME0 JDIMMG0 JDIMMG1 JDIMMH0 JDIMMH1 JDIMMA0 JDIMMA1 JDIMMB0 JDIMMB1 CPU0 CPU1 CPU1 CPU0 JDIMM_G0 JDIMM_A0 JDIMM_G1 JDIMM_A1 JDIMM_H0 JDIMM_B0 JDIMM_F0 JDIMM_D0 JDIM...

Страница 26: ...User s Manual 2 2 2 DIMM Installation Procedure Unlock a DIMM socket by pressing the retaining clips outward Insert module vertically and press down until it snaps into place Note DIMM notch and socke...

Страница 27: ...p SB212 PH User s Manual 2 3 Removing and Installing the Chassis Top Cover Step 1 Loosen the captive screws x 2 securing the cover to the chassis Step 2 Pull the cover towards the rear panel Step 3 Li...

Страница 28: ...ing the Hard Disk Drive 2 4 1 Installing the Hard Disk Drive Step 1 Place the HDD into tool less HDD tray untli it snaps Please check if the screw holes on HDD match the dimples on HDD tray The HDD ca...

Страница 29: ...y into chassis HDD cage Make sure the drive tray is correctly secured Push the tray lever until it reaches the end and clicks 2 4 2 Removing the hard disk drive Step 1 Press the tray lever and pull th...

Страница 30: ...stalling the Fan Module 2 5 1 Removing the fan module Pull to remove the fan module out of the enclosure Make sure to remove the rubbers out from the fan bar 2 5 2 Installing the fan module Make sure...

Страница 31: ...dule 2 6 1 Removing the power supply unit module Step 1 Remove the power cables Step 2 Push the latch and hold the tray handle Step 3 Pull the PSU module tray handle out gently to slides out the PSU m...

Страница 32: ...r s Manual 2 7 Removing and Installing the PCIe support bracket 2 6 1 Removing the PCIe support bracket Remove the lower PCIe support bracket by unscrewing the screws x 4 2 6 2 Installing the PCIe sup...

Страница 33: ...o screws securing the bracket to the chassis Step 2 Align the connector on the riser card with the gold finger on the motherboard assembly and insert the riser card into the motherboard assembly Push...

Страница 34: ...rdware Setup 26 SB212 PH User s Manual Step 3 Secure the card retainer to the chassis using the retaining screw Step 4 Push forward the card retainer lock the PCI E card to hold it in place Card Retai...

Страница 35: ...ssembly 2 9 1 Installing the riser card Step 1 Align the connector on the riser card with the gold finger on the motherboard assembly Step 2 Push the edge of the gold finger firmly into the motherboar...

Страница 36: ...e card retainer to the chassis using the retaining screw Push forward the card retainer lock the PCI E card to hold it in place Step 4 Perform the following steps after installing a PCIe Card Step 5To...

Страница 37: ...o screws securing the bracket to the chassis Step 2 Align the connector on the riser card with the gold finger on the motherboard assembly then insert the riser card into the motherboard assembly Push...

Страница 38: ...e card retainer to the chassis using the retaining screw Push forward the card retainer lock the PCI E card to hold it in place Step 4 Perform the following steps after installing the PCIe Card SEE 2...

Страница 39: ...2 PH User s Manual 2 11 Tool less Blade Slide Installation Step 1 Pull on the Front Release to unlock the inner channel from the slide assembly Step 2 Release the detent lock and push middle mhannel i...

Страница 40: ...are Setup 32 SB212 PH User s Manual Metal Spacer Optional Remove Metal Spacer for Aluminium Racks Step 3 Align the front bracket with the mounting hole Step 4 Push inward to assemble the front bracket...

Страница 41: ...dware Setup SB212 PH User s Manual Step 5 Now the bracket is fixed onto the rack Optional M6x10L screws are to secure the rails with posts if needed Step 6 Refer to Step 3 4 to assemble the rear brack...

Страница 42: ...r 2 Hardware Setup 34 SB212 PH User s Manual Step 7 Assemble the inner channel onto the chassis using the screws provided Step 8 Push the chassis with inner channels into slide to complete rack instal...

Страница 43: ...1 ECC DDR 4 1333 1600 2133 2400 TDP 6 1W Wellsburg PCH Port1 IOU2 PCI E Gen3 8GT s X8 SFP x2 XL710 82599 SATAPort 0 5 SATA 0 SATA 1 SATA 2 SATA 3 Port 3a x8 support NTB Golden Finger X16 Golden Finger...

Страница 44: ...LCM RJ45 RJ45 VGA COM USB 3 0 USB 3 0 JUSB_INT JVGA_INT RSMRST LED RSMRST LED RSMRST LED JPCH_GPIO JPMBUS JPMBUS JDOM_PWR JSPKR JBUZZER JCPU_XDP JBMC_I2C10 JBMC_I2C10 JBAT JBAT JPWR2 JPWR1 SYS PG LED...

Страница 45: ...7 COM4 JCOM4 25 BMC Reset JBMC_RST 8 Front USB JUSB_INT 26 BMC Disable JBMC_DIS 9 QPI CONN JQPI_TX JQPI_RX 27 System PG Lock JPG_LOCK 10 XDP CONN Intel Debug Port 28 BMC Buzzer JBUZZER 11 DIMM Socket...

Страница 46: ...T JUSB_INT JBMC_DP JCOM4 JBMC_GPIO JLCM RJ45 RJ45 VGA COM USB 3 0 USB 3 0 JUSB_INT JVGA_INT RSMRST LED RSMRST LED RSMRST LED JPCH_GPIO JPMBUS JPMBUS JDOM_PWR JSPKR JBUZZER JCPU_XDP JBMC_I2C10 JBMC_I2C...

Страница 47: ...CH FAN6_TACH FAN5_TACH FAN4_TACH FAN3_TACH FAN2_TACH FAN1_TACH PWM4 PWM3 PWM2 PWM1 3 3V_DUAL 3 3V_DUAL 3 3V 3 3V GND SYS_HEALTH HD_LED 3 3V_DUAL UID_SW_IN_N FP_NMI_BTN SW_RST_BTN SW_PWR_BTN JFRNT JFRN...

Страница 48: ...s Jumpers SCOM2_T3OUT SCOM2_R4IN GND E JBMC_DP GND I2C9SDA I2C9SCL EXTRST BMC_GPY1 BMC_GPY0 F JBMC_GPIO G JBMC_I2C1 I2C1SDA GND I2C1SCL NC CLK_33M_DP80 PCH_LFRAME_N RST_PLTRST_N PCH_LPC_LAD3 3 3V PCH_...

Страница 49: ...s Jumpers Heart Bit LED UID LED JPCH_GPIO JINTRUDER RSMRST LED RSMRST LED RSMRST LED JPCH_GPIO JPMBUS JPMBUS JSGPIO JSGPIO JDOM_PWR JSPKR JBUZZER JBMC_I2C10 JBMC_I2C10 J3 J2 J2 J3 JCMOS JBMC_RST J4 JB...

Страница 50: ...CH_FP_USB3_RX_P2 GND PCH_FP_USB3_TX_N2 PCH_FP_USB3_TX_P2 GND PCH_FP_USB2_N2 PCH_FP_USB2_P2 PCH_USB_OC 23 Internal Connectors Jumpers B JPCH_GPIO PCH_GPIO8 PCH_GPIO21 GND C JPMBUS SMB_PMBUS_CLK SMB_PMB...

Страница 51: ...SB212 PH User s Manual SYS PG LED JCPU_XDP JPWR2 JPWR1 SYS PG LED JPG_LOCK JPG_LOCK A B Internal Connectors Jumpers A JPWR2 8 12V 12V 12V 12V GND GND GND GND B JPWR1 GND GND GND GND GND GND PS_ON 12V...

Страница 52: ...inking 1G link detected activity detected 82599 Activity detected XL710 NIC 1 Left Upward Triangle Green Blinking 10G link detected activity detected 82599 1 10G link detected XL710 NIC 2 Right Downwa...

Страница 53: ...t active SYS PG LED ON System power good ready OFF System power good is not ready RSMRST PG LED ON Resume Well Reset ready OFF Resume Well Reset is not ready UID LED ON UID activity detected OFF UID n...

Страница 54: ...B Setting Short Downstream port Open Upstream port Default Default C JBMC_DIS JBMC_DIS Setting Short Disable Open Normal Default D J3 J3 Setting Short BIOS Recovery Mode Open Normal Default E J2 J2 Se...

Страница 55: ...guration Settings Step 1 Press ESC to run the setup procedure Caution When Quiet Boot IS enabled OEM LOGO WILL BE displayed INSTEAD OF POST MESSAGES Step 2 Choose SCU to enter the Setup menu Caution F...

Страница 56: ...48 Chapter 4 BIOS Configuration Settings SB212 PH User s Manual Step 3 Identify the BIOS Version Step 4 Load Optimal Default setting Step 5 Save the setting and exit the BIOS setup utility...

Страница 57: ...uring POST 1 Prepare a USB mass storage device 2 Put BIOS bin file and mflash cfg in Root directory 3 Plug the USB mass storage device into a USB port of the target computer 4 Turn on system 5 Boot to...

Страница 58: ...If you need to update Flash in the DOS environment please use H2offt d utility To use this utility you must include the flash bat H2offt d exe and bin file in the same folder Please follow the instru...

Страница 59: ...apter 5 BMC Configuration Settings Insert Ethernet LAN cable into the BMC LAN port There are two methods to setup BMC IP 5 1 Method 1 Use the BIOS Setup Step 1 Enter BIOS SETUP Advanced H2O IPMI confi...

Страница 60: ...Chapter 5 BMC Configuration Settings SB212 PH User s Manual 52 Step 2 Type in the IP address Configure the static IP...

Страница 61: ...Chapter 5 BMC Configuration Settings SB212 PH User s Manual 53 Step 3 Type in the subnet mask address...

Страница 62: ...Settings SB212 PH User s Manual 54 5 2 Method 2 Use a Dos Tool Syscheck Step 1 Type in sc lanset Step 2 Modify IP setting Step 3 Type in the IP address Note type 1 for selecting static IP mode or typ...

Страница 63: ...er s Manual 55 Step 4 Type in the submask address The IP address below is an example using a default IP setting The IP address is configurable Step 5 Complete the BMC IP configuration Note Type sc exe...

Страница 64: ...dress is configurable Step 1 Open the browser then type default BMC IP address 192 168 22 22 Step 2 Use the default user name and password for first time login to BMC WEB GUI Field Default UserName ad...

Страница 65: ...on Settings SB212 PH User s Manual 57 Dashboard The Dashboard page gives the overall information about the status of a device Server Health Sensor Readings The Sensor Readings page displays all the se...

Страница 66: ...s group of pages allows you to access various configuration settings Mouse Mode Settings The KVM Mouse Setting page allows you to configure the mouse mode to relative absolute and other For Windows OS...

Страница 67: ...Chapter 5 BMC Configuration Settings SB212 PH User s Manual 59 Remote Control The Remote Control page allow you to access any of the managed devices within your system...

Страница 68: ...Chapter 5 BMC Configuration Settings SB212 PH User s Manual 60 Environmental setting Press ALT C for local and remote OS mouse control switching...

Страница 69: ...A SB301C01 a bat This is just an example The latest BMC firmware version is available from the FAE or AIC website 4 After update BMC firmware please power off and then power on system Refer to AIC BMC...

Страница 70: ...tw CHINA Tel 86 21 54961421 86 21 54961422 Fax Extension 608 Email Technical Support support aicipc com AMERICA West coast Tel 1 909 895 8989 Fax 1 909 895 8999 Email sales aicipc com AMERICA East coa...

Отзывы: