AIC SB102-UR Скачать руководство пользователя страница 45

35

Chapter 3. Hardware Settings

SB102-UR User Manual

3�4�2 Jumper

51  

ME Firmware Recovery Mode 

      Jumper Setting (J41)

       Function: ME Recovery

11 

 Password Clear Jumper Setting (J39)

       Function: Password clear

6   

BIOS CMOS Clear Jumper Setting (J46)

     Function: BIOS CMOS Clear Jumper Function

  Manufacturing Mode Jumper Setting 

      (J90)

      Function: Manufacturing Mode

10 

 Non-maskable Interrupt Switch      

      Jumper Setting (J96)

      Function: Non-maskable interrupt    

      switch

CPU0

CPU1

5

26

45

51

11

6

9

Содержание SB102-UR

Страница 1: ...UM_SB102 UR_v1_042319 SB102 UR Storage Server Barebone User s Manual...

Страница 2: ...ion 8 2 2 2 DIMM Location 9 2 2 3 DIMM Slot Installation Order 10 2 3 Top Cover 11 2 4 Power Supply Unit Module 12 2 4 1 Replacing the Power Supply Unit 12 2 5 Fan Module 13 2 5 1 Replacing the Fan 13...

Страница 3: ...42 4 4 Advanced 43 4 4 1 iSCSI Configuration 43 4 4 2 Trusted Computing 43 4 4 3 Serial Port Console Redirection 44 4 4 4 PCI Subsystem Settings 44 4 4 5 Network Stack Configuration 44 4 4 6 Memory RA...

Страница 4: ...rity 51 4 8 1 Security 51 4 8 2 Secure Boot 52 4 9 Boot 53 4 9 1 Boot 53 4 10 Save and Exit 54 4 10 1 Save and Exit 54 Chapter 5 BMC Configuration Settings 55 5 1 Login 55 5 2 Web GUI 56 5 2 1 User In...

Страница 5: ...Copyright 2019 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Страница 6: ...Document Release History Release Date Version Update Content April 2019 1 User s Manual release to public...

Страница 7: ...le for compliance could void your authority to operate the equipment Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein The information provided is prov...

Страница 8: ...ully mount the equipment into the rack in such manner that it won t be hazardous due to uneven mechanical loading This equipment is to be installed for operation in an environment with maximum ambient...

Страница 9: ...he equipment does not work well or will not work according to its user manual 5 The equipment has been dropped and or damaged 6 The equipment has obvious signs of breakage 7 Please disconnect this equ...

Страница 10: ...ttings This chapter elaborates the overall layout of the server including multifarious connectors jumpers and LED descriptions These descriptions assist users to configure different settings and funct...

Страница 11: ...are damaged If any damage is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and verify t...

Страница 12: ...2 x SATA 7 pin IPMI Aspeed AST2500 Advanced PCIe Graphics Remote Management Processor Baseboard Management Controller Intelligent Platform Interface 2 0 IPMI 2 0 iKVM Media Redirection IPMI over LAN...

Страница 13: ...and width and utilization In addition to the noteworthy features of the barebone SB102 UR provides immediate and efficient management with Onboard Baseboard Management Controller and greater I O exten...

Страница 14: ...el 10 x 2 5 SATA tray System button and LED indicator Rear Panel 2 x 10GbE SFP 500W 1 1 redundant power supply 80 Platinum or 800W 1 1 redundant power supply 80 Platinum BTO 1 x GbE RJ45 for BMC DB 15...

Страница 15: ...5 Chapter 1 Product Features SB102 UR User Manual Major Components 500W 1 1 redundant power supply 80 Platinum or 800W 1 1 redundant power supply 80 Platinum BTO 7 x 4028mm hotswap fans...

Страница 16: ...essor socket are vulerable and easily susceptible to damage if fingers or any foreign objects are pressed against them Please keep the socket protective cover on when the processor is not installed WA...

Страница 17: ...lation Position the heat sink on top of the CPU Secure the screws on the heat sink Removal Dislodge the screws x 4 on the heat sink Remove the heat sink by lifting it upward NOTE Failure to tighten th...

Страница 18: ...ts with 6 channel per CPU 2 2 1 DIMM Installation Unlock the dimm socket by pressing the retaining clips outward Insert the memory module into the slot Make sure that the Dimm notch is accurately posi...

Страница 19: ...RDIMM LRDIMM NVDIMM N Verify if all of the DIMMs installed are of the same DIMM type to avoid memory failure and loss of performance speed CPU0 CPU1 DIMM C0 DIMM C1 DIMM B0 DIMM B1 DIMM A0 DIMM A1 DIM...

Страница 20: ...10 Chapter 2 Hardware Setup SB102 UR User Manual 2 2 3 DIMM Slot Installation Order Populate the DIMM slots according to the suggested order below to ensure a stable system performance...

Страница 21: ...ware Setup SB102 UR User Manual 2 3 1 Removing the Top Cover Press the release button x 2 on the top cover Slide the top cover towards the rear end of the system barebone Lift the cover upward to remo...

Страница 22: ...Replacing the Power Supply Unit Press the latch to release the module Pull the handle to remove the module out of the chassis Push the replaced power supply unit into the chassis Ensure that the modul...

Страница 23: ...rubber connectors from the attached bracket Insert the replaced fan into the node Verify to align the rubber connectors with the appropriate slot in the bracket NOTE The fan should be blowing toward...

Страница 24: ...osen the lever Pull the tray lever outward completely Pull the tray out of the system Insert the hard disk drive into the tray Ensure that the dimples on the tray match the hard disk drive For additio...

Страница 25: ...eplacing the HDD Backplane Detach the cables and hard disk drives from the backplane module Dislodge the screws on the module Lift the module upward to remove Insert the replaced HDD backplane into th...

Страница 26: ...g the Riser Card Loosen the captive screw Pull upward to remove the riser card from the system Insert the replaced riser card into the appropriate card slot Ensure that the card is properly aligned Se...

Страница 27: ...17 Chapter 2 Hardware Setup SB102 UR User Manual Locate the positon of airduck as demonstrated below Make sure to position it on top of the fan modules 2 9 Airduck...

Страница 28: ...d fall due to incorrect installation or placed on uneven grounds The rack must be placed in a flat surface before you begin to slide the system barebone in for servicing Pull the inner rail out of the...

Страница 29: ...ck the keyholes and secure the screws Continue installing the outer rail bracket to the mounting frame Attach the outer rail assembling to the frame and press the bracket to fix the rail onto the fram...

Страница 30: ...ull out the middle channel until the ball bearing retainer is locked forward CAUTION Verify ball bearing retainer is locked forward Slide the release tab and push barebone into rack Make sure the bare...

Страница 31: ...er 3 Hardware Settings SB102 UR User Manual Chapter 3 Hardware Settings This section provides illustrations that display the internal jumpers connectors and system LED indicators 3 1 Motherboard Block...

Страница 32: ...er Manual Chapter 3 Hardware Settings 3 2 Motherboard Layout CPU0 CPU1 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 30 31 32 33 34 35 36 37 38 39 41 42 43 44 45 46 47 48 49 50 51 1 2 3 4 5 6...

Страница 33: ...r 0 CPU0 12 PCI E X16 Gen3 Slot2 J59 38 Fan Connector 2 J99 13 PCI E X16 Gen3 Slot1 J58 39 Fan Connector 1 J98 14 NIC OCP 2 0 Connector B J75 40 DIMM Slots for Processor 0 J11 J12 J9 J10 J7 J8 15 PCI...

Страница 34: ...LERT N B22 PS CR BUS R A23 PS1 VSENSE DN B23 PS LOAD SHARE A24 PS1 VSENSE DP B24 PS1 Present N A25 PS1 DCOK B25 PS1 ACOK 23 Power Supply Connectors J85 Pin Description Pin Description A1 Ground B1 Gro...

Страница 35: ...5 Pin Description Pin Description 1 Ground 9 12V 2 Ground 10 12V 3 Ground 11 12V 4 Ground 12 12V 5 Ground 13 12V 6 Ground 14 12V 7 Ground 15 RST_I2C_HDDBP_N 8 I2C_HDDBP_SDA 16 I2C_HDDBP_SCL 20 Rear 2H...

Страница 36: ...4_ ESD_DN 19 PSV_USB3_FRONT2 3 PCH_USB3_RX_P4_ ESD_DP 18 PCH_USB3_RX_P5_ ESD_DN 4 Ground 17 PCH_USB3_RX_P5_ ESD_DP 5 PCH_USB3_TX_P4_ ESD_DN 16 Ground 6 PCH_USB3_TX_P4_ ESD_DP 15 PCH_USB3_TX_P5_ ESD_DN...

Страница 37: ...0 2 TPM_Vendor_ID1 3 TPM_PRSNT_N 4 LPC_AD_1 5 LPC_FRAME_TPM_Module_N 6 LPC_SERIRQ 7 Ground 8 3V3 9 Clock_33M_PCH_LPC_TPM5 10 RST_LPC_TPM_Module_N 11 Ground 12 LPC_TPM_Module_AD 2 13 3V3_STBY 14 Groun...

Страница 38: ..._C_DN B6 PCH_SATA_TX_P1_C_DN A7 Ground B7 Ground A8 SGPIO_SATA_DATA0 B8 SGPIO_SATA_CLOCK A9 TP_SATA0_RSVD_A9 B9 SGPIO_SATA_LOAD A10 Ground B10 Ground A11 TP_SATA0_RSVD_A11 B11 TP_SATA0_RSVD_B11 A12 TP...

Страница 39: ...Ground A17 PCH_SATA_RX_P7_C_DP B17 PCH_SATA_TX_P7_C_DP A18 PCH_SATA_RX_P7_C_DN B18 PCH_SATA_TX_P7_C_DN A19 Ground B19 Ground 16 Slimline Connector 2 J70 Pin Description Pin Description A1 Ground B1 Gr...

Страница 40: ...X_S5_C_DN 2 PCH_SATA_TX_S5_C_DP 6 PCH_SATA_RX_S5_C_DP 3 PCH_SATA_TX_S5_C_DN 7 5V_SATADOM_2 4 Ground 8 5V 9 Ground 49 SATA SATADOM Connectors sSATA 4 J74 Pin Description Pin Description 1 Ground 5 PCH_...

Страница 41: ...tion Pin Description 1 Ground 4 BMC_FAN_PWM_2_R 2 PU_FAN_ID_2 5 PU_FAN_INSTALL_2_N 3 BMC_FAIL_2_R 6 12V 36 Fan Connectors 3 J100 Pin Description Pin Description 1 Ground 4 BMC_FAN_PWM_3_R 2 PU_FAN_ID_...

Страница 42: ...2 PU_FAN_ID_5 5 PU_FAN_INSTALL_5_N 3 BMC_FAIL_5_R 6 12V 30 Fan Connectors 6 J103 Pin Description Pin Description 1 Ground 4 BMC_FAN_PWM_6_R 2 PU_FAN_ID_6 5 PU_FAN_INSTALL_6_N 3 BMC_FAIL_6_R 6 12V 34 F...

Страница 43: ...tion 1 Ground 2 PU_VROC_CONN_PIN2 3 Ground 4 FM_PCH_SATA_RAID_KEY_R 2 Internal Serial Header J2043 Pin Description Pin Description 1 COM1_RES_DCD 2 COM1_RES_RX_N 3 COM1_RES_TX_N 4 COM1_RES_DTR 5 Groun...

Страница 44: ...LD2SSIFP_R_N 7 3V_FP 8 LED_HLTH_GRN_CPLD2SSIFP_R 9 DC_LED_HDD_ACT_CPLD2SSIFP_R_N 10 LED_HLTH_RED_CPLD2SSIFP_R 11 BTN_PWRON_SSIFP2CPLD_N 12 3V_Standby_FP 13 Ground 14 LED_NIC0_LINK_ACT_R_N 15 BTN_RST_S...

Страница 45: ...ery 11 Password Clear Jumper Setting J39 Function Password clear 6 BIOS CMOS Clear Jumper Setting J46 Function BIOS CMOS Clear Jumper Function 9 Manufacturing Mode Jumper Setting J90 Function Manufact...

Страница 46: ...User Manual Chapter 3 Hardware Settings 3 5 1 Connector and Jumper Location Top view Bottom view 3 5 HDD Backplane 2 Bay HDD1 HDD2 SATA Connector J8 SATA Connector J5 SATA Connector J1 SATA Connector...

Страница 47: ...ser Manual 3 5 2 Connector Power connector JP1 LED I O Connector Pin Description Pin Description 1 HDD1 Fault LED 2 HDD Fault LED input Low active 3 VCC 4 GND 5 HDD Activity LED 6 HDD Activity LED inp...

Страница 48: ...38 SB102 UR User Manual Chapter 3 Hardware Settings 3 6 1 Connector and Jumper Location Top view Bottom view 3 6 HDD Backplane 4 Bay HDD1 HDD3 HDD2 HDD4 CN6 CN7 JTAG JCPLD_SEL JACT_LED JFAIL_LED...

Страница 49: ...ction and Setting JCPLD SEL Pin Status Description 1 2 Open Disable External Access LED input JP11 Close Enable External Access LED input JP11 3 4 Open Access LED from HDD Pin P11 Close Access LED fro...

Страница 50: ...on Select item Enter Select and enter sub screen Modify selected option F1 General help F2 Previous Value F3 Optimized defaults F4 Save Exit F5 F6 Change values F7 Discard Change and Exit F9 Load Opti...

Страница 51: ...as PCH miscellaneous and server ME configuration Socket Configuration Allows configuration of socket settings such as processor Common RefCode UPI and memory configurtaion BMC Allows configuration of...

Страница 52: ...42 SB102 UR User Manual Chapter 4 BIOS Configuration Settings 4 3 1 Main Main Option Key Option Key Description System time Configures current time System date Configures current date 4 3 Main...

Страница 53: ...nced Option Key 4 4 1 iSCSI Configuration iSCSI Configuration Add an Attempt Delete Attempts Change Attempt Order 4 4 2 Trusted Computing Trusted Computing Security Device Support Enable Disable TPM S...

Страница 54: ...iguration Network Stack Enable Disable Ipv4 PXE Support Enable Disable Ipv4 HTTP Support Enable Disable Ipv6 PXE Support Enable Disable Ipv6 HTTP Support Enable Disable PXE boot wait time 0 1 2 3 4 5...

Страница 55: ...210ms 260ms to 900ms 1s to 3 5s 4s to 13s 17s to 64s No PCIe port active EC0 PCU Squelch exit ignore option Reset the SQ FLOP by CSR option 4 4 9 IIO1 Configuration IIO1 Configuration IOU2 IIO PCIe P...

Страница 56: ...d I O VT d Intel VT for Directed I O VT d Enable Disable Interrupt Remapping Enable Disable Pass Through DMA Enable Disable ATS Enable Disable Coherency Support Non Isoch Enable Disable Coherency Supp...

Страница 57: ...On board device PCIE Device RTC Wake system from S4 S5 Enable Disable 4 5 3 Server ME Configuration Server ME Configuration General ME Configuration Configures Server ME Technology Parameters Oper Fi...

Страница 58: ...rocessor Configuration Hyper Threading Enable Disable Enable Intel R TXT Enable Disable VMX Enable Disable Enable SMX Enable Disable Extended APIC Enable Disable Force x2APIC IDs Enable Disable AES NI...

Страница 59: ...1T MMIO High Granularity Size 1G 4G 16G 64G 256G 1024G Numa Enable Disable 4 6 5 Memory Configuratiuon Memory Configuration Memory Frequency Auto 1866 2133 2400 2666 Enable ADR Enable Disable Erase A...

Страница 60: ...2 Timer FB 2 Timer Enable Disable 4 7 2 FB 2 Timer Policy FB 2 Timer Do Nothing Reset Power Down Power Cycle 4 7 3 BMC Network Configuration BMC Network Configuration Configuration Address source Unsp...

Страница 61: ...administrator password in the Create New Password window After you key in the password the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Creat...

Страница 62: ...Attempt Secure Boot Enable Disable Secure Boot Mode Standard Custom Key Management Provision Factory Default keys Install Factory Default Keys Enroll Efi Image Save All Secure Boot Variables Platform...

Страница 63: ...apter 4 BIOS Configuration Settings SB102 UR User Manual Boot Option Key 4 9 1 Boot Boot Bootup NumLock State On Off Quiet Boot Enable Disable New Boot Option Policy Default Place First Place Last 4 9...

Страница 64: ...tem after saving the changes Discard Changes and Reset Resets system setup without saving any changes Save Changes Saves the changes Discard Changes Discards the changes Restore Defaults Restores or l...

Страница 65: ...nfigurable Open the browser then type in the default BMC IP address 192 168 22 108 Use the default user name and password for first time BMC WEB GUI login Field Default UserName admin Password admin N...

Страница 66: ...are allowed except for the configuration commands that can change the behavior of the out of hand interfaces Administrator All BMC commands are allowed No access Login access denied Notification Click...

Страница 67: ...supports BMC Watchdog Timer Commands 5 2 3 System LED Indicator System LED System Health Front Panel Green On Control By CPLD System is Good No Error Off Normally in Standby Amber Blink 1Hz Non Critic...

Страница 68: ...on ready approximate 120 sec then send the Set SEL Time command with the current system time to sync RTC timer In runtime on every BMC reset BMC will assert GPIO to generate SMI to BIOS then BIOS woul...

Страница 69: ...ype SSOL Authentications Administrator Administrator access over SOL Non Volatile Bit Rate 115200 115200 baud rate Volatile Bit Rate 115200 115200 baud rate Gratuitous ARP Interval 4 seconds ARP respo...

Страница 70: ...X Integrity None O O O O X HMAC SHA1 96 O O O O X HMAC MD5 128 O O X X X MD5 128 X X X X X HMAC SHA2 128 X X X X X Confidentiality None O O O O X AES CBC 128 O O O O X XRC4 128 X X X X X XRC4 40 X X X...

Страница 71: ...0 Yes Yes 800x600 60 Yes Yes 1024x768 60 Yes Yes 1280x800 60 Yes Yes 1280x1024 60 Yes Yes 1440x900 60 Yes Yes 1600x1200 60 Yes Yes 1680x1050 60 Yes Yes 1920x1080 60 Yes Yes 1920x1200 60 Yes Yes Full S...

Страница 72: ...62 Chapter 5 BMC Configuration Settings SB102 UR User Manual Select Remote Control from the menu bar The KVM window will pop up Click the button Start KVM To terminate the KVM service click Stop KVM...

Страница 73: ...ting it If the boot loader detects that the loaded firmware image is invalid it will not be executed BMC will select another SD storage for boot If Both of ROMs part are fail BMC SOC will reboot by WD...

Страница 74: ...aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 6730 Fax 1 510 573 6729 Sales Email sales aicipc com Support Em...

Отзывы: