background image

UM_SB101-SP_v1.3_012020

SB101-SP

Storage Server Barebone

User's Manual

Содержание SB101-SP

Страница 1: ...UM_SB101 SP_v1 3_012020 SB101 SP Storage Server Barebone User s Manual...

Страница 2: ...4 2 5 2 Installing the Fan 14 2 6 Removing and Installing the Hard Disk Drive 15 2 6 1 Removing and Installing the Hard Disk Drive Tray 15 2 6 2 Installing the Hard Disk Drive 15 2 7 Removing and Inst...

Страница 3: ...tion 38 4 5 1 Platform Configuration 38 4 5 2 PCH Configuration 39 4 5 3 Miscellaneous Configuration 40 4 5 4 Server ME Configuration 40 4 6 Socket Configuration 41 4 6 1 Socket Configuration 41 4 6 2...

Страница 4: ...2 6 FRU Information 56 5 2 7 Logs and Reports 57 5 2 8 Settings 58 5 2 9 Remote Control 60 5 2 10 Power Control 65 5 2 11 Chassis Identify Control 66 5 2 12 Set Front Panel Enables 66 5 2 13 Maintenan...

Страница 5: ...Copyright 2019 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Страница 6: ...nt Release History Release Date Version Update Content January 2019 1 User s Manual release to public July 2019 1 1 Note sign update August 2019 1 2 Slide rail update January 2020 1 3 Specifications u...

Страница 7: ...for compliance could void your authority to operate the equipment Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein The information provided is provid...

Страница 8: ...ully mount the equipment into the rack in such manner that it won t be hazardous due to uneven mechanical loading This equipment is to be installed for operation in an environment with maximum ambient...

Страница 9: ...Do not use liquid or detergent for cleaning The use of a moisture sheet or cloth is recommended for cleaning Module and drive bays must not be empty They must have a dummy cover CAUTION The equipment...

Страница 10: ...ttings This chapter elaborates the overall layout of the server including multifarious connectors jumpers and LED descriptions These descriptions assist users to configure different settings and funct...

Страница 11: ...damaged If any damage is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and verify that...

Страница 12: ...solution 2 x SATA 6 0 Gb s by 2 x SATA 7 pin RAID 0 1 5 10 support by Intel RSTe IPMI Aspeed AST2500 Advanced PCIe Graphics Remote Management Processor Serial over LAN Network Controllers on rear I O...

Страница 13: ...In addition to the noteworthy features of the barebone SB101 SP provides immediate and efficient management with Onboard Baseboard Management Controller and greater I O extension Featuring IPMI 2 0 a...

Страница 14: ...LED indicator Rear Panel 2 x USB 3 0 double stack Type 450W 1 1 Redundant PSU optional 500W single PSU BTO 1 x GbE RJ45 for BMC DB 15 VGA port DB 9 COM port Power On Off Switch System HDD Activity LE...

Страница 15: ...5 Chapter 1 Product Features SB101 SP User Manual Major Components 450W 1 1 Redundant PSU optional 500W single PSU BTO 6x4028 system fans optional 6x4056 system fans BTO...

Страница 16: ...setup you need to prepare before installation a T20 Torx screwdriver ESD wrist strap mat and conductive foam pad CAUTION The pins of the processor socket are vulerable and easily susceptible to damag...

Страница 17: ...rver board includes two processor sockets LGA 3647 supports one or two of the Intel Xeon Processor Scalable Family and has a Thermal Design Power TDP of up to 165W on selected models PHM Processor Hea...

Страница 18: ...red in the following order as shown below Processor Heat Sink Top View with Screw Tightening Order CAUTIUON Failure to tighten the heat sink screws in the specified order may cause damage to the proce...

Страница 19: ...llation Step 1 Unlock the dimm socket by pressing the retaining clips outward Step 2 Insert the memory module into the slot Make sure that the DIMM notch is accurately positioned Step 3 Close the reta...

Страница 20: ...To ensure satisfactory performance you need to Verify the DIMM type DDR4 ECC RDIMM LRDIMM 2666 2400 2133 Verify if all of the DIMMs installed are of the same DIMM type to avoid memory failure or loss...

Страница 21: ...DIMM_F0 DIMM_F0 DIMM_E0 DIMM_E0 DIMM_E1 DIMM_E1 DIMME_F1 DIMME_F1 DIMM_C1 DIMM_C1 DIMM_B1 DIMM_B1 DIMM_A1 DIMM_A1 DIMM_C0 DIMM_C0 DIMM_B0 DIMM_B0 DIMM_A0 DIMM_A0 CPU 1 CPU0 4 DIMM CPU 1 CPU 0 DIMM_A1...

Страница 22: ...ep 1 Press the release button x 2 on the top cover Step 2 Slide the top cover towards the rear end of the system barebone Step 3 Lift the cover upward to remove 2 3 Removing the Top Cover This informa...

Страница 23: ...2 Pull the handle to remove the module out of the system 2 4 2 Installing the Power Supply Unit Align and push the module into the system until it is hooked into the housing Check if the module is pr...

Страница 24: ...racket 2 5 2 Installing the Fan Step 1 Insert the module into the system Verify to align the rubber connectors with the appropriate slot in the bracket NOTE The fan should be blowing toward the rear e...

Страница 25: ...ward completely Step 3 Pull the tray out of the system 2 6 2 Installing the Hard Disk Drive Insert the hard disk drive into the tray Ensure that the dimples on the tray match the hard disk drive For a...

Страница 26: ...g the hook Step 3 Dislodge the screws on the module Step 4 Lift the module upward to remove 2 7 2 Installing the HDD Backplane Step 1 Slide the module into the system Step 2 Secure the module into the...

Страница 27: ...et from the system 2 8 2 Installing the Riser Card Step 1 Align and insert the riser card with bracket into the appropriate card slot Ensure that the card is properly aligned Step 2 Secure the captive...

Страница 28: ...fall due to incorrect installation or placed on uneven grounds The rack must be placed in a flat surface before you begin to slide the system barebone in for servicing 1 Pull the inner rail out of the...

Страница 29: ...secure the screws on sides of the system 5 Continue installing the outer rail bracket to the mounting frame Attach the outer rail assembling to the frame and press the bracket to form a rack on both...

Страница 30: ...il the ball bearing retainer is locked forward NOTE Verify ball bearing retainer is locked forward 7 Slide the release tab and push barebone into rack Make sure the barebone is completely installed on...

Страница 31: ...dware Settings SB101 SP User Manual This section provides illustrations that display the internal jumpers connectors and system LED indicators for the system 3 1 Motherboard Block Diagram Chapter 3 Ha...

Страница 32: ...onnector PCH_SATA2 9 CPU1 FAN Connector CPU1_FAN 28 SFP Port1 not available for 1G J5010 10 System Fan 3 Connector SYS_FAN_3 29 SFP Port2 not available for 1G J5009 11 IPMB Connector IPMB_HD1 30 USB F...

Страница 33: ...0 DIMM_E0 DIMM_F0 DIMM_C1 DIMM_B1 DIMM_A1 DIMM_D1 DIMM_E1 DIMM_F1 Battery BMC BIOS PCIe_7 x8 PCIe_6 x16 PCIe_5 x8 PCIe_4 x16 PCIe_3 x8 PCIe_2 x8 PCIe_1 x8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 21...

Страница 34: ...HD_VGA_DAT HD_VGA_B HD_VGA_G HD_VGA_R VGA_5V 1 13 VCC3 12V GND PS_ON GND GND GND RES VCC5 VCC5 VCC5 GND 12 24 VCC3 VCC3 GND VCC5 GND VCC5 GND PWR_OK 5VSB VCC12 VCC12 VCC3 1 PCH_SATA_RAID_KEY GND VCC3...

Страница 35: ...24 SSATA_DOM0 23 SSATA_DOM SSATA DOM Connector 1 5 SMB_CLK SMB_DAT SMB_ALERT GND VCC3 LAN1_LED LAN1_LED INTRUSION SMBCLK SMBDATA LAN0_LED LAN0_LED SYS_FAULT2 SYS_FAULT1 IDLED IDLED VCC3_AUX 1 2 NMI_S...

Страница 36: ...26 SB101 SP User Manual Chapter 3 Hardware Settings 3 5 1 Layout Top view Bottom view 3 5 HDD Backplane...

Страница 37: ...ng Pin Status Description Pin 1 2 Open Disable External LED input Close Enable External LED input Pin 3 4 Open Activity LED from HDD Pin P11 Close Activity LED from SGPIO Pin 5 6 Open Identify behavio...

Страница 38: ...Indicator HDD Activity LED Blue On HDD is present Blue Blinking HDD activity is detected or HDD is located Off HDD is not connected or the power is off HDD Fault Status LED Off Red On HDD fault occur...

Страница 39: ...Power On Self Test POST To enter BIOS after POST you have to restart the system by using one of the three methods Press Ctrl Alt Delete Press the reset button on the system chassis Turn the system off...

Страница 40: ...m Configuration Allows configuration of platform settings such as PCH miscellaneous and server ME configuration Socket Configuration Allows configuration of socket settings such as processor Common Re...

Страница 41: ...31 Chapter 4 BIOS Configuration Settings SB101 SP User Manual 4 3 Main 4 3 1 Main Main Option Key Option Key Description System time Configures current time System date Configures current date...

Страница 42: ...32 SB101 SP User Manual Chapter 4 BIOS Configuration Settings 4 4 Advanced Advanced Option Key 4 4 1 iSCSI Configuration iSCSI Configuration Add an Attempt Delete Attempts Change Attempt Order...

Страница 43: ...Disks Read only 4 4 3 Trusted Computing Trusted Computing Security Device Support Enable Disable 4 4 4 APCI Settings ACPI Settings Enable ACPI Auto Configuration Enable Disable Enable Hibernation Enab...

Страница 44: ...S5 RTC Wake Settings Wake System from S5 Disable Fixed Time Dynamic Time Wake up hour Select 0 23 Wake up Minute increase 1 5 Wake up minute Select 0 59 for Minute Wake up second Select 0 59 for Secon...

Страница 45: ...ings Out of Band Mgmt Port COM1 Terminal Type VT UTF8 VT100 VT100 ANSI Bits per Second 115200 9600 19200 57600 Flow Control None Hardware RTS CTS Software Xon Xoff Data Bits Read only Parity Read only...

Страница 46: ...ilter UEFI and Legacy Legacy only UEFI only Network Legacy Do not launch UEFI Storage Legacy Do not launch UEFI Video Legacy Do not launch UEFI Other PCI Devices Legacy Do not launch UEFI 4 4 14 USB C...

Страница 47: ...37 Chapter 4 BIOS Configuration Settings SB101 SP User Manual 4 4 15 NVDIMM ADR Configuration NVDIMM ADR Configuration Assert ADR on Reset Enable Disable Assert ADR on Shutdown Enable Disable...

Страница 48: ...iguration 4 5 1 Platform Configuration Platform Option Key Option Key Description PCH Configuration Displays and provides option to change the PCH Settings Miscellaneous Configuration Configures activ...

Страница 49: ...sable Configure SATA as AHCI RAID Port 0 Enable Disable Hot Plug Enable Disable Configure as eSATA Enable Disable Spin Up Device Enable Disable SATA Device Type Hard Disk Drive Solid State Drive SATA...

Страница 50: ...n Reset ADR Enable Enable Disable Enable Disable ADR Timer Enable Held off ADR timer expire time 25 uS 50 uS 100 uS 0 us ADR timer multiplier x1 x8 x24 x40 x56 x64 x72 x80 x88 x96 4 5 3 Miscellaneous...

Страница 51: ...r Settings Common RefCode Configuration Displays and provides option to change the Common RefCode Settings UPI Configuration Displays and provides option to change the UPI Settings Memory Configuratio...

Страница 52: ...djacent Cache Prefetch Enable Disable Extended APCI Enable Disable 4 6 3 Common RefCode Configuration Common RefCode Configuration MMCFG 1G 1 5G 1 75G 2G 2 25G 3G MMCFG Size 64M 128M 256M 512M 1G 2G M...

Страница 53: ...Sparing Enable Disable Correctable Error Threshold 1 32767 SDDC Plus One Enable Disable ADDDC Sparing Enable Disable Patrol Scrub Enable Disable 4 6 6 IIO Configuration IIO Configuration Socket 0 Con...

Страница 54: ...ieBr4D00F0 MCP 0 Socket 1 PcieBr5D00F0 MCP 1 PCI E Port Auto Enable Disable Hot Plug Capable Enable Disable PCI E Port Link Enable Disable Link Speed Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s PCI...

Страница 55: ...able Disable CPU Core Flex Ratio 23 Hardware PM State Control Hardware P States Disable Native Mode Out of Band Mode Native Mode with NO Legacy Support CPU C State Control CPU C6 report Disable Enable...

Страница 56: ...nutes 4 minutes 5 minutes 6 minutes FRB 2 Timer Policy Do Nothing Reset Power Down Power Cycle OS Watchdog Timer Enable Disable OS Wtd Timer timeout 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd T...

Страница 57: ...3 BMC Network Configuration BMC Network Configuration Configure IPV4 Support Management Port 1 Configuration Address Source Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Server Management Port...

Страница 58: ...istrator password in the Create New Password window After you key in the password the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New...

Страница 59: ...Secure Boot Enable Disable Secure Boot Mode Standard Custom Key Management Provision Factory Default keys Install Factory Default Keys Enroll Efi Image Save All Secure Boot Variables Platform Key PK K...

Страница 60: ...key 65535 0xFFFF means indefinite waiting Bootup NumLock State On Off Quiet Boot Enable Disable Boot Option Priorities Boot Option 1 Device Name Disable New UEFI OS Boot Option Policy Default Place Fi...

Страница 61: ...Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of the setup options Discard Change...

Страница 62: ...Step 1 Open the browser then type in the default BMC IP address 192 168 22 108 Step 2 Use the default user name and password for first time BMC WEB GUI login Field Default UserName root Password supe...

Страница 63: ...s of IPMI event and video Settings The Settings page allows you to configure various basic settings such as date time KMV Mouse Services and ect Remote Control The Remote Control page allows you to re...

Страница 64: ...mands are allowed except for the configuration commands that can change the behavior of the out of hand interfaces Administrator All BMC commands are allowed No access Login access denied Notification...

Страница 65: ...hboord page displays device system and network information Click Dashboard on the menu bar to view the overall information of the server 5 2 4 Sensor The Sensor page displays the status and records on...

Страница 66: ...including Vendor name Model and Sofware version Click System Inventory on the menu bar to open 5 2 6 FRU Information The FRU Information page displays Basic Information Chassis Information Board Infor...

Страница 67: ...r 5 BMC Configuration Settings 5 2 7 Logs and Reports The System Inventory page displays IPMI Event Log and Video Log Click Logs and Reports from the menu bar select Event Log or Video Log to view the...

Страница 68: ...ngs page displays the configuration settings for Date Time External User Services KVM Mouse Setting Log Settings Media Redirection Settings Network Settings PAM Order Settings Platform Event Filter Se...

Страница 69: ...ettings VMedia Instance Settings Remote Session Network Settings Network Settings Network Link Configuration DNS Configuration Sideband Interface NC SI PAM Order Settings PAM Authentication Order Plat...

Страница 70: ...BMC Configuration Settings SB101 SP User Manual 5 2 9 Remote Control The Remote Control page displays the configuration for power control and remote KVM Click Java Console to start the JViewer video...

Страница 71: ...61 SB101 SP User Manual Chapter 5 BMC Configuration Settings Click Launch KVM to open the Remote KVM page...

Страница 72: ...Manual Procedure To Start KVM Step 1 Click Start KVM to start the H5Viewer video redirection Step 2 Click Browse to select CD Image Step 3 Click Start Media to redirect the selected CD image file to t...

Страница 73: ...Mode This option handles mouse emulation from local window to remote screen using either of the two methods Only Administrator has the right to configure this option Absolute mouse mode The absolute...

Страница 74: ...epressed the CTRL ALT and DEL keys down simultaneously on the server that you are redirecting Left Windows This menu item can be used to act as the left side WIN key when in Console Redirection You ca...

Страница 75: ...options of Power Control are given below Power Off To immediately power off the server Power On To power on the server Power Cycle This option will first power off and then reboot the system cold boo...

Страница 76: ...ays the BMC s UID control information Users can change the Identify LED behavior on this page Click Chassis Identify Control from the menu bar Select Off On to control UID LED 5 2 12 Set Front Panel E...

Страница 77: ...Maintenance This Maintenance page displays the configuration settings for Backup Configuration Firmware Image Location Firmware Information BIOS Information Fimware Update Preserve Configuration Resto...

Страница 78: ...ically follow if the upgrade is completed or cancelled An option to Preserve All Configuration is available Enable it if you wish to preserver configured settings through the upgrade Click Start Firmw...

Страница 79: ...hapter 5 BMC Configuration Settings 5 2 14 Sign out To log out of the BMC Method 1 Click Sign out from the menu bar The Logout dialog box will pop out Method 2 Click the root quick button on the top r...

Страница 80: ...aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 6730 Fax 1 510 573 6729 Sales Email sales aicipc com Support Em...

Отзывы: