25
J2012-01User Manual
Chapter 3 Sub-system Configuration Setup
3.5.2 How to configure T10 zoning
After enabling T10 zoning, five predefined groups are Group1, Group8, Group9, Group10, and
Group11. Each PHY should be in one of the five groups, and all PHYs in a wide port should
be in the same group. Each PHY in Group1 can access any PHY in other groups, and vice
versa. Each PHY in Group8 cannot access any PHY in Group9, and vice versa. The command
syntax is "phyzone phy_index group." The following example shows how to set up one drive
accessed only by the first port and another drive accessed only by the second port.
The configuration for the example is
(A) PHY0 - PHY3 for the first wide port
(B) PHY4 - PHY7 for the second wide port
(C) PHY12 - PHY35 for drive
Step 1
: Read the current group for PHY4.
cmd> phyzone 4
Phy 4 for Zone Group 1
Step 2
: Assign the second port (PHY4 - PHY7) for Group9.
cmd> phyzone 4 9
cmd> phyzone 5 9
cmd> phyzone 6 9
cmd> phyzone 7 9
Step 3
: Assign the first port (PHY0 - PHY3) for Group8.
cmd> phyzone 0 8
cmd> phyzone 1 8
cmd> phyzone 2 8
cmd> phyzone 3 8
Step 4
: Assign the drive on PHY12 to be accessed only by the first port instead of the
second port.
cmd> phyzone 12 8
Step 5
: Assign the drive on PHY13 to be accessed only by the second port instead of
the first port.
cmd> phyzone 13 9
Step 6
: Reset for taking effect with the new settings.
cmd> reset
Содержание J2012-01
Страница 1: ...UM_J2012 01_v4_120319 J2012 01 12Gb s SAS JBOD Series User s Manual...
Страница 35: ...26 J2012 01User Manual Chapter 3 Sub system Configuration Setup...
Страница 61: ...52 Chapter 3 BMC Configuration Settings J2012 01User Manual 4 2 Sensor s Location for Fan Temperature...
Страница 90: ...81 J2012 01User Manual Chapter 3 BMC Configuration Settings 4 Click Proceed 5 Processing 6 Successful update...