TM5-250_B

 

 

 

    

LP0859X 10/10

 

 

 

 

 

TACHTROL

20

 

RATE METER   

MODEL 

T77250-10

 

 

• RATE INDICATION 
• 6-DIGIT 0.56" (14.2 mm) HIGH RED LED DISPLAYS 

• INPUT RATES UP TO 25KHz 

• ACCEPTS A WIDE VARIETY OF SENSORS 

• PROGRAMMABLE SCALING 

• PROGRAMMABLE UPDATE TIME 
• PROGRAMMABLE DECIMAL POINTS 
• NEMA 4X / IP65 SEALED FRONT BEZEL 

 

 

GENERAL DESCRIPTION 

The 

TACHTROL

20

  Rate  Meter,  Model  T77250-10,  provides  the  versatility  and  flexibility  needed  to 

accommodate  virtually  any  rate  measuring  application.  The  meter  has  the  ability  to  scale  for  direct 
readout  in  terms  of  the  units  being  measured.  Whether  a  machine  produces  bottles,  cloth,  wire,  or 
beverage  mix,  operation  is  enhanced  when  the  rate  readout  is  expressed  directly  in  bottles/min., 
feet/min., gallons/min., or whatever units are needed in plant applications. 

The 

TACHTROL

20

  can  accommodate  magnetic  pickups,  logic  sensors,  and  NPN  open  collector  sensors. 

The  pulses  are  received  and  scaled,  so  the  desired  display  can  be  achieved.  The  meter  is  programmed 
through  both  the  front  panel  buttons  and  DIP  switches.  Once  the  programming  is  complete,  the  front 
panel buttons can be disabled by a DIP switch setting. 

The meter has been specifically designed for harsh industrial environments. With a NEMA 

4X/IP65 

sealed 

bezel and extensive testing to meet CE requirements, the meter provides a tough, yet reliable application 
solution. 

SAFETY SUMMARY 

All safety related regulations, local codes and instructions that appear in the literature or on equipment 

must be observed to ensure personal safety and to prevent damage to either the instrument or equipment 
connected to it. If equipment is used in a manner not specified by the manufacturer, the protection 
provided by the equipment may be impaired. 

 

 

 

 

 

 

 

 

152 Knotter Dr. 
Cheshire CT 06410 USA 
PH: 203-271-6000 Fax: 203-271-6200 
www.aiteksensors.com

 

 

CAUTION: 

Risk of Electric shock 

 

 

CAUTION: Risk of Danger 

Read complete instructions prior to 

installation and operation of the unit. 

 

Содержание TACHTROL20 T77250-10

Страница 1: ...rs The pulses are received and scaled so the desired display can be achieved The meter is programmed through both the front panel buttons and DIP switches Once the programming is complete the front panel buttons can be disabled by a DIP switch setting The meter has been specifically designed for harsh industrial environments With a NEMA 4X IP65 sealed bezel and extensive testing to meet CE require...

Страница 2: ...DC 100mA max 3 SENSOR POWER 9 to 17 5 VDC 100mA max 4 KEYPAD 3 programming keys the Down Arrow key can also function as the front panel reset button 5 INPUT DIP switch selectable Accepts pulses from a variety of sources including NPN OC PNP OC TTL Outputs and Magnetic Pickups Logic Input trigger levels V il 1 5 V max V ih 3 75 V min Current Sinking Internal 7 8 KΩ pull up to 12 VDC I max 1 9 mA Cu...

Страница 3: ...ipment for Measurement Control and Laboratory use IMMUNITY TO INDUSTRIAL LOCATIONS Electrostatic discharge EN 61000 4 2 Criteria 4 kV contact discharge A 8 kV air discharge Electromagnetic RF fields EN 61000 4 3 10 V m 80 MHz to 1 GHz A 3 V m 1 4 GHz to 2 GHz 1 V m 2 GHz to 2 7 GHz Fast transients burst EN 61000 4 4 2 kV power A 3 1 kV I O signal Surge EN 61000 4 5 power 1 kV L to L 2 kV L to G A ...

Страница 4: ...re Wire Strip Length 0 3 7 5 mm Clamp screw Torque 4 5 inch lbs 0 51 N m max 11 CONSTRUCTION This unit is rated for NEMA 4X IP65 outdoor use IP20 Touch safe Installation Category II Pollution Degree 2 One piece bezel case Flame resistant Synthetic rubber keypad Panel gasket and mounting clip included 12 WEIGHT 12 oz 340 g ...

Страница 5: ...n the slots on the case The panel latch should be engaged in the farthest forward slot possible To achieve a proper seal tighten the latch screws evenly until the unit is snug in the panel Torque to approximately 7 in lbs 79N cm Do not over tighten the screws INSTALLATION ENVIRONMENT The unit should be installed in a location that does not exceed the maximum operating temperature and provides good...

Страница 6: ...n of the input parameters and program disable SWITCH 1 SNK Adds internal 7 8 KΩ pull up resistor to 12 VDC I 1 9 mA MAX SWITCH 2 SRC Adds internal 3 9 KΩ pull down resistor 8 mA max 30 VDC max SWITCH 3 HI Frequency Removes damping capacitor and allows max frequency LO Frequency Limits input frequency to 50 Hz and input pulse widths to 10 msec SWITCH 4 LOGIC Input trigger levels VIL 1 5 V max VIH 3...

Страница 7: ...pplication Listed below are the recommended methods of connecting the shield in order of their effectiveness a Connect the shield only at the panel where the unit is mounted to earth ground protective earth b Connect the shield to earth ground at both ends of the cable usually when the noise source frequency is above 1 MHz c Connect the shield to common of the meter and leave the other end of the ...

Страница 8: ... Terminal 3 DC OUT IN DC Terminal 2 AC L2 Terminal 4 COMM DC INPUT WIRING Magnetic Pickup AC Inputs From Tach Generators Etc Two Wire Proximity Current Source Current Sinking Output Current Sourcing Output Interfacing With TTL Emitter Follower Current Source Switch position is application dependent ...

Страница 9: ...her calculations are needed If only the number of pulses per single unit i e of pulses per foot is known then it can be entered as the Scaling Input value and the Scaling Display value will be entered as the following NOTES 1 If number of pulses per unit is less than 10 then multiply both Input and Display values by 10 2 If number of pulses per unit is less than 1 then multiply both Input and Disp...

Страница 10: ...lues Also the meter starts accumulating the number of falling edges When the time reaches the Low Update Time value the meter looks for one more falling edge to end the sample period If a falling edge occurs before the High Update Time value is reached the Rate display will update to the new value and the next sample period will start on the same edge If the High Update Time value is reached witho...

Страница 11: ... not affect scaling calculations Press the arrow keys or to sequence through the selection list until the desired selection is shown Press the PAR key to save the displayed selection and advance to the next parameter ENTERING NUMERICAL VALUES The parameters which follow are displayed as a multi digit numerical values with one selected digit flashing initially the far left digit Press the up arrow ...

Страница 12: ...eter briefly displays End upon exiting Programming Mode All programmed selections are now transferred to the nonvolatile memory and the meter returns to the Rate display If power loss occurs during programming mode verify parameter changes and reprogram if necessary when power is restored PROGRAMMING MODE TIME OUT The Programming Mode has an automatic time out feature If no keypad activity is dete...

Страница 13: ...efend and indemnify AI Tek against damages claims and expenses arising out of subsequent sales of AI Tek products or products containing components manufactured by AI Tek and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer...

Отзывы: