AHT Cooling Systems GmbH
page 11
A limited number of semi-automatic defrosts can be
performed (see
→
chapter 4.2.1.3).
Depending on the setting, individual variations of
interior equipment (air ducts, floor grilles, partition
grilles, standing baskets) are possible.
NOTICE
•
Property damage
due to missing interior.
►
Wall grills must be used in every setting.
►
Never operate in refrigerator setting without air
ducts and floor grills.
All units are equipped with load lines (see
→
chapter
All units are classified in the equipment family
horizontal closed transparent (HCT).
Automatic defrost
Triggered by a factory-set time, the unit starts one
defrost cycle per week (during night time).
Defrost cycle stops automatically when ice/frost is
removed (triggered by the internal temperature sensor
or software based max. time out period).
During automatic defrost the display shows
“dEF”
(see
→
chapter 4.2.1).
The accumulated defrost water is drained to the engine
room and gets evaporated.
CAUTION
Leakage of defrosted water.
Slipping hazard.
►
Check for puddle formation in front of
and below the device.
►
Remove spilled defrosted water
immediately.
►
Contact maintenance services (see
→
chapter 10.4) immediately.
4 Operating and display elements
Temperature display
Indication of indoor temperature:
(see
→
chapter
Indoor temperature check:
Responsibility
:
operating staff
Frequency:
several times a day
Operating panel and display elements
To get to the operating panel, remove the protection
acrylic cover with a screwdriver.
CAUTION
Removal of the protection acrylic cover with a
screwdriver. Stab injury.
►
Carefully handling with tool.
►
Select the proper size of the screwdriver to
avoid slipping.
►
After use ensure that the screwdriver is kept
neatly and safely.
NOTICE
•
Property damage
due to incorrect parameter
changes.
►
Reinstall protection acrylic cover after operation.
Electronic controller AHT (SECOP)
Three buttons are available as control elements.
Fig.1: Electronic controller
Nr. Control
element
Function
1
Button
[+/-]
Change of setting
(e.g. A1,A2)
2
Button
[MAN.
DEFROST]
Semi-automatic defrost
3
Button
[STANDBY
RESET]
Manual defrost
Switch on/off refrigeration
function
Error code selection
(when red light is on)
Acknowledge acoustic
alarm
Nr. Display
Meaning
4
luminous red
dot on
alarm
Switch refrigeration function on/off
Switch off (manual defrost):
Press
Button
[STANDBY RESET]
for at least
3 seconds.
„---“ is shown at the display.
Switch on:
Press
Button
[STANDBY RESET]
for at
least 3 seconds.
At the display the current temperature is
shown.
Setting selection
Available settings (see
→
chapter 2.2)
Show current setting:
Press button
[+/-]
briefly.
e.g. „
A1“
is shown at the display.
Change setting:
By pressing button
[+/-]
several times, all
available settings can be addressed.
Confirm shown setting:
Wait 5 seconds.
4