13.
14.
12.
Connect the same colour cold lead between the thermostat and the connector
in the junction box.
10
Expose the conductor in each lead.
9.
Connect all leads of the same colour.
10.
Insert each coloured lead to one connector in the junction box.
11.
Brown cold leads
coming from the
heating mats
Brown wire coming from
the thermostat in an
electric conduit
Blue wire coming from the
thermostat in an electric conduit
Floor sensor wire
coming from the
thermostat in an
electric conduit
Blue cold leads
coming from the
heating mats
Connect the wires to the control thermostat according to the Typical Wiring
Diagram on page 12.
Switch on the heating system (see the directions in your thermostat manual)
for half an hour to ensure that the system is working properly. It is important to
check each entire system to ensure each mat is heating.
Switch off the heating system (see the directions in your thermostat manual).
When the mats are cool, lay down your floor covering. If you are installing a glued
type of floor covering (carpet, wood, vinyl or linoleum), first cover the mats with
at least 1/4 inch (6mm) self leveling flooring cement. (You can also use similar
materials,like Latex based self leveling compound, as long as they have the same
or better Thermal conductivity as the self leveling flooring cement). Consult your
local construction material dealer regarding the right material for your type of floor.
15.
16.
If you are installing a glued type of floor covering, or using thin-set or
grout or tile adhesive, do not switch on the heating system again until
the glue, thin-set, or grout or tile adhesive is dry. Consult the manufacturer
of the material used to determine the amount of drying time needed.
Important!