For your reference, make a note of the serial number, date of purchase and 
supplier here.

Serial No. 

Purchase Date

Supplier 

observed.

13.   PRODUCT DISPOSAL

Informa on on the disposal of electrical and electronic devices in the European 
Community
The disposal of electrical devices is regulated within the European Community by 
na onal regula ons based on EU Direc ve 2012/19/EU on waste electrical and 
electronic  equipment  (WEEE).  According  to  these  regula ons,  any  devices 
supplied a er 13.06.05 in the business to business sphere, to which this product is 
assigned, may no longer be disposed off in municipal or domes c waste. They are 
marked with the following symbol to indicate this.

As disposal regula ons within the EU may vary from country to country, please 
contact your supplier if necessary.

10

Содержание myLab UC-01

Страница 1: ...AHN myLab UC 01 Universal Centrifuge 4500 rpm Instruction Manual ...

Страница 2: ......

Страница 3: ...RECAUTIONS 2 7 INSTALLATION 3 Ÿ Loca on and Moun ng 8 USER INTERFACE AND DISPLAY 4 9 OPERATING THE CENTRIFUGE 5 Ÿ Switch on the Centrifuge Ÿ Speed Se ng Ÿ Time Se ng Ÿ Acc Dcc Ÿ PRG Ÿ Quick Spin Ÿ PEdit program Ÿ Rotor Ÿ Start Stop 10 MAINTENANCE AND CLEANING 7 11 TROUBLESHOOTING 7 12 WARRANTY STATEMENT 9 13 PRODUCT DISPOSAL 10 ...

Страница 4: ......

Страница 5: ...lease read this user manual carefully This user manual is intended to assist with the opera on and care of the unit only and not its repair For repairs pleasecontactthesupplier 3 SALIENTFEATURES Centrifugehasfollowingfeatures Deliversupto4500RPMforallcompa blerotors BLDCmaintenancefreemotordrive Imbalancedetec onsafetywithautocutofffeature Lidlocksafetyfeature Lid doesnotopenduringopera on Programm...

Страница 6: ... tubes must not be centrifuged This is because broken tubescanresultinsamplelossandcancreateimbalancewhichcanresultin Ÿ furtherdamagetothecentrifugeand accessories Ÿ Do not fill tubes while they are in the rotor Liquids spillage may harm the device If liquids are spilled on the rotor or rotor chamber the centrifuge must becleanedcarefullyandproperlybeforebeingusedagain Ÿ Centrifuge may be used for ...

Страница 7: ...fuge Ÿ For safety we have provided protec ve earthing with power supply Make sure powersupplyisearthened 7 INSTALLATION The Laboratory centrifuge is supplied in packaging box Open the box remove the packaging and gently place the centrifuge out of the box Before 1st me usage open the centrifuge ensure to remove all packaging from the rotor chamber Pleasekeepallpackaginginsafestorageforatleast2year...

Страница 8: ... 99 00 Timer can be set from1 to 99 min Short press of Plus and Minus buttons will increase and decrease speed time ACC DCC values normally Long press of these keys would change the parameters quicker 6 Acceleration Deceleration First Single press Acceleration will display on time segment like ACC1 We can change acceleration using and buttons 1 to 9 Second Single press Deceleration will display on...

Страница 9: ...ma cally once the blinking stops The mer can be set in minutes only while seconds are for countdown mer for running opera on Acc Dcc This bu on will set the parameters of accelera on or decelera on of the rotor ramp Press acc dcc bu on once to set the accelera on from 1 9 by using bu on for increment decrement respec vely Similarly press once again the acc dcc bu on to set decelera on from 1 9 by ...

Страница 10: ...peed Timer accelera on decelera on automa cally one a er the other These parameter will be asked by the instrument sequen ally to be entered if required to be changed if not edited the display value will set These parameters will save automa cally Rotor Press rotor bu on to select rotors as listed below The rotor numbers can be changedbyusing forincrementordecrementoftherotornumber Rotor Rotor No ...

Страница 11: ...re thorough cleaning use a neutral cleaning agent Ph between 6 and 8 and clean with a so cloth Exclusiveamountsofliquidshouldbeavoided Note Liquidshouldnotcomeintocontactwiththemotor A ercleaning ensurethatallpartsaredrybeforere use Regularlycleaningoftherotorisimportant If the rotor chamber needs cleaning clean with cloth or sponge moistened withaneutraldetergentsolu on Donotplacetherotorintothec...

Страница 12: ...metrically restart centrifuge Err 55 No display No main power connection Power check proper plug in of mains cable at both ends Power failure Check the mains fuse of the lab Connect adaptor properly Improper connection Lid not closed correctly Close lid correctly Contact service Error with lid closing and opening mechanism ERROR PROBLEM SOLUTION Err 1 Latch damaged Latch jammed Contact service rep...

Страница 13: ... for the product or use of products as well as any supervision required for safety If requested the products must be returned to the distributor in well packed and insured manner and all shippingchargesmustbepaid Some states do not allow limita on on the length of implied warran es or the exclusion or limita on of incidental or consequen al damages This warranty gives you specific legal rights This...

Страница 14: ...ithin the European Community by na onal regula ons based on EU Direc ve 2012 19 EU on waste electrical and electronic equipment WEEE According to these regula ons any devices supplied a er 13 06 05in the business to business sphere to which this product is assigned may no longer be disposed off in municipal or domes c waste They are markedwiththefollowingsymboltoindicatethis As disposal regula ons ...

Страница 15: ......

Страница 16: ...137 97 0000 02 003 R1 2020 AHN Biotechnologie GmbH AHN Biotechnologie GmbH Uthleber Weg 14 D 99734 Nordhausen Germany Phone 49 0 3631 65242 0 Fax 49 0 3631 65242 90 E Mail info cappahn com www ahn bio de ...