© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
3
Remove the cover by looseneing the two bottom screws and removing the top two screws.
Tilt the cover back to clear the light pipes and then remove the cover.
The PCB has several connection and configuration options as described:
Component Locations
O8
O7
GND
O6
O4
O2
IN4
IN2
+5V
O5
GND
O3
GND
O1
GND
IN3
GND
IN1
GND
GND
2
1
3
4
1. I/O Screw Terminal Block
Make connections to analog sensor inputs and transistor outputs.
2. Input Jumper Select Block
Set input channels to current mode (0-20mA) instead of voltage (VX12i only)
3. Power Input Terminals
Optional input power terminals for hard wire applications.
4. LED Light Pipes
Indicators for each of the eight (8) outputs; red when on. Pipes protrude through front panel openings.