Setup

To setup and install the free software you must be using a Windows operating system.

1. Download the installer from Agrowtek’s website.

2. Open the installer and follow the command prompts.

3. If you are given a security warning asking permission to modify files (install them,) select YES.

Connect the USB AgrowLINK and allow the drivers to automatically install. Wait until a message is displayed 

in the task bar indicatin the device is ready to use (it may take several minutes.) If the device drivers fail to 

install, you can install them from the BatchMaster software. 

Driver Installation

If the device drivers have not automatically installed:

1. Open the BatchMaster program.

2. Ignore warnings that advise the AgrowLINK was not detected (press OK.)

3. From the top menu bar select: USB AgrowLINK > Install Driver. 

4. The driver installer will open; follow the command prompts to complete the driver installation.

Detect the AgrowLINK

If your AgrowLINK was not connected before you opened the program, you can search for it by selecting: 

USB AgrowLINK > Detect AgrowLINK.

BatchMaster Software Setup

Running a Recipe

Each pump may have a setting for the dose volume (mL) and the flow rate of the pump (mL/min). 

To create a batch recipe:

1. Set the flow rate for each pump. Most applications will use the pumps at full speed. The speed may be 

reduced if required for your application.

2. Set the volume that each pump should dose.

3. Save the recipe if desired by selecting: File > Save. Choose a location and name the file then press “Save.”

Saved recipies may be recalled by selecting: File > Open and choosing a recipe file.

Run a Batch

Once the recipe is configured, it may be “run” by pressing the green “play” button. The pumps will begin dos-

ing with the first pump. Once the specified volume is completed, the next pump will begin. When all pumps 

have metered the volume in the recipe, the batch is complete.

Stop Pumps

All pumps may be stopped immediately by pressing the red “stop” button. 

Prime

Each pump may be primed for 10 seconds automatically by pressing the “Prime” button for the respective 

pump. The pump will operate at the speed selected allowing the speed to be previewed or tested.

Содержание ADi

Страница 1: ...Minimum Dose Size AD350 5mL Contents Dimensions 2 Installation Instructions 3 Connecting Pump Tubing 3 Connection to GrowControl GCX 4 GrowNET Hubs 4 Connection to SXHM Controller 5 Cross Over Cable...

Страница 2: ...Agrowtek Inc www agrowtek com Technology to Help You Grow 2 Mounting Holes dia 0 201 n number of pump heads Dimensions 1 n 2 75 4 38 0 38 n 2 75 4 51 3 75...

Страница 3: ...o avoid over tighteneing the screws and bending the flanges A 120Vac wall receptacle is required within 6ft of the pump for the power adapter Installation Instructions FROM SAMPLE PUMP WATER TANK RETU...

Страница 4: ...g sensors and most relays directly over the CAT5 cable A DC jack on the hub provides 24Vdc power to the ports from the included wall power supply A terminal block power option is also available DIELEC...

Страница 5: ...form a powerful autono mous pH and EC set point dosing system Operate a single dual or quad AgrowDose pump and configure each pump as an EC part or pH up or down part Automatically maintains pH and E...

Страница 6: ...ects Agrowtek s devices to a computer s USB port for Connection to USB AgrowLINK Technology to Help You Grow AGROWtEK U S A MADE IN www agrowtek com GrowNET Device Hub TM USB AgrowLINKTM LX1 USB to Gr...

Страница 7: ...not connected before you opened the program you can search for it by selecting USB AgrowLINK Detect AgrowLINK BatchMaster Software Setup Running a Recipe Each pump may have a setting for the dose vol...

Страница 8: ...1 Alternate speeds and formats between 9 600 115 200 baud may be configured with the free AgrowLINK PC utility using a LX1 USB AgrowLINK and the cross over adapter supplied with the LX2 ModLINK MODBU...

Страница 9: ...de 0 5A Motor 2 1mm jack center positive Motor Life Motor life and service intervals can be tracked by observing the pump motors accumulated run time which is tracked in seconds in a 32 bit unsigned i...

Страница 10: ...rsion ASCII 8 char R 40016 Motor Speed Pump 1 0 100 16 bit unsigned R W 40101 Pump 2 16 bit unsigned 40102 Pump 3 16 bit unsigned 40103 Pump 4 16 bit unsigned 40104 Pump 5 16 bit unsigned 40105 Pump 6...

Страница 11: ...s of time lost profits or savings or any other incidental consequential or special damages arising out of the use of or inability to use the product This disclaimer is made to the fullest extent allow...

Отзывы: