AGS 2500/3000 EN-HP
USER MANUAL – rev.2016/12
page
107
This requires:
-
either removing water from the pump, the regulator, the hoses, the filters and other
elements…;
-
either storing the device in a warm space;
-
or using an agent against freezing (antifreeze).
13.2.10 Procedure of protecting the sprayer with anti-freezing agent
After you have finished cleaning the spraying device, completely empty the tank and pour at
least 10 litres of antifreeze agent (a mixture of water and antifreeze) and turn on the pump.
Open all valves on the regulator in order the antifreeze agent can reach all hoses and nozzles.
At the end, empty the remaining agent from the tank in a suitable container and let the pump
operate for few more minutes in order to pump the remaining agent into the tank.
WARNING:
Make sure that the antifreeze agent is poured into appropriate
containers! Do not discard antifreeze agents in nature!
Protect the manometer against freezing by unscrewing it from the regulator and storing it in a
warm room. The manometer must be stored in an upright position or the glycerine filling can
flow out!
13.2.11 Possible faults
FAULT SIGNS
PROBABLE CAUSE
CONTROL/REPAIR
No flow on nozzle,
when starting the pump
and opening main valve
on flow regulator.
-
Closed manual valve on suction side;
-
Clogged suction or pressure filter;
-
Air in suction line;
-
Damaged or incorrectly installed
valves in pump;
-
Check valves on suction line to pump;
-
Clean or replace filter insert;
-
Check tightness of hose connections on
suction side;
-
Check and, if required, replace pump
valves;
Uneven crop protection
liquid jet.
-
Incorrect pressure in air chamber;
-
Control air pressure in air chamber and
fill it according to diagram data;
Pressure on manometer
drops or work pressure
cannot be achieved.
-
Clogged pressure or suction filter;
-
Cracked pressure hose;
-
Open valve on self-cleaning filter;
-
Incorrect choice or worn out nozzle
inserts;
-
Clean or replace filter insert;
-
Replace hose;
-
Close valve on self-cleaning filter;
-
Check nozzle flow – if greater than 10%,
replace them;
Pressure on manometer
is changing severely.
-
Air in suction line;
-
Damaged diaphragms;
-
Check tightness of hose connections in
suction line.
-
Stop the pump immediately.
-
Replace diaphragms and pump oil.
Noisy pump.
-
Oil level too low;
-
Exceeded RPM;
-
Check oil level and add, if required;
-
Check RPM;
Crop protection liquid in
pump oil
-
Damaged diaphragms.
-
Stop the pump immediately;
-
Replace diaphragms and pump oil;
-
Clean pump interior with gas oil before
installing new diaphragms.
Содержание AGS 2500 EN-HP
Страница 2: ......
Страница 8: ...VI...
Страница 10: ...VIII...
Страница 113: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 103 PARAMETER VALUE NOTE imp l d1 d2 d3 d4 d5 d6 d7 D Imp km l ha...
Страница 120: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 110 14 3 Dimensions and weight...
Страница 127: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 117 16 COMBINATION MATRIX 16 1 Combination matrix AGS 2500 EN HP...
Страница 128: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 118 16 2 Combination matrix AGS 3000 EN HP...
Страница 129: ...AGS 2500 3000 EN HP USER MANUAL rev 2016 12 page 119 17 NOTES...
Страница 130: ...USER MANUAL rev 2016 12 AGS 2500 3000 EN HP page 120...
Страница 131: ......