INSTRUCTIONS FOR USE
AGP 300 – 600 PRO
Rev.02/2019
33
7.9.5
Multiplier gearbox
The multiplier gearbox is used for the transmission of torque from the pump to the fan via the
flange. It provides two-speed transmission which can be disengaged to stop the rotation (fan
switch-off). The multiplier gearbox and the pump are connected by means of a flange. The
multiplier gearbox is lubricated with the SAE 90 oil. It can be checked thought the window (6 −
Figure 7.7) and added through the filler plug (3 − Figure 7.7).
Figure 7.10
SWITCH-OFF AND GEAR
CHANGING
The multiplier gearbox with a shaft that
propels the fan has a switch-off lever
mounted at the side that switches off the
rotation or speed level of the fan. This way
the mist blower can be used for other
purposes (preparing the spraying mixture,
mixing, spraying with a manual spraying
lance etc.).
Technical data:
Multiplier gearbox type
COMER D21F
Gear ratio
i
1 : 3,5–0–1 : 5
Lubrication oil
SAE 90
Oil volume
l
1.75
7.9.6
Nozzle holders
As standard, mist blowers are equipped with double diaphragm nozzle holders and various nozzle
inserts (nozzles and their flows are described in a separate chapter). Nozzle holders are essentially
valves with the following functions:
WARNING: Only switch the fan on and off with the multiplier lever when
the PTO drive shaft is disengaged!