3
EXAMINATION
TECHNICAL SPECIFICATION
Problem
Cause
Remedies
1. DC Motor Doesn’t work
No Power or loose plug
Charge or check plug
2. Automatic stop during
spraying
Overheat damaged
intelligent controller
Pause then continue
spraying after cooling down
3. No water Sprayers,
Nozzle
Jammed Nozzle
Air in hose
Clean nozzle
Check hose tighten, release
air
Instable water Pressure
Jammed Pump
Broken hose
Check pump clean eye
winker
Change new one
Lower Pressure and saller
Smaller flux
Jammed filter in hose
Jammed filter in sprayer
switch
Lower Voltage
Clean filter
Clean Filter
Change new one
Leakage in tie – in
Loose tie-in
Broken O ring
Tighten Screw
Check new one
Sprayer doesn’t work well
Jammed nozzle
Broken Sprayer core
Clean eye winker
Change new One
Pump Motor starts then cut
sometimer when stop spray
Eye winker in the Switch
Rubber Seal Hose
Leakage at the pump
Open and clean
Tighten
Tighten
Model
AM ZOOM
Name
Battery Sprayer
Tank Capacity
16L
Pump Rate
3L
Battery
8AH with regulator
Lance
Brass thread with bend, LED bulb of 3 meters cable