![AGRI TRONIX DIGI-STAR GT400 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/agri-tronix/digi-star-gt400/digi-star-gt400_operators-manual_2869498019.webp)
Short Form Calibration
D3831 Rev B
GT400 User’s Manual
15
CALIBRATION NUMBER
The “CAL” number is adjusted to make scale read proper weight for different
load cells and to make accuracy adjustments on a scale system. Systems
should be checked with known weights and adjusted if necessary to insure
accuracy. Both setup and calibration numbers are changed to convert a scale
from lbs to kgs.
Calibrating Scale For Maximum Accuracy
Note:
To accurately calibrate scale, you need a large amount of weight that
has a known value. For best results you should have at least as much weight
as largest load you plan to weigh.
Determining New Setup and
Calibration Numbers
The setup number does not change.
1. Press to Zero-Balance.
2. Put KNOWN WEIGHT on scale
platform and write down DISPLAY
WEIGHT.
Perform following equation to find
ACCURATE CAL NUMBER.
1
Содержание DIGI-STAR GT400