![AGRI TRONIX Brecknell SBI-521 Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/agri-tronix/brecknell-sbi-521-series/brecknell-sbi-521-series_service-manual_2869497010.webp)
8
SBI521 Service Manual
Figure 1.2 Main Board
1.4.1 Weigh Platform or Loadcell Connections
Connect the loadcell cable to the loadcell connector on the main board. Connection
assignments for the loadcell connector are shown in
. Refer to
for loadcell jumper configuration.
Figure 1.3 Loadcell Connector
Table 1.1 Loadcell Connections
Board
Designaltion
Description
Pin
Electrical Level
E+
+ excitation
1
5
±
0.3 VDC (
≤
0.12A)
SE+
+ sense
2
5
±
0.3 VDC
E-
- excitation
3
0 VDC
SE-
- sense
4
≤
0.5 VDC
S+
+ signal
5
2.5
±
0.3 VDC
S-
- signal
6
2.5
±
0.3 VDC
SFG
ground/shield
7
N/A
1
7
E+
SE+
E-
SE-
S+
S-
SFG