background image

units, light etc. 

Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall

plants etc.

CONNECTION: 

Warning. Danger of death through electric shock! 

Must be installed by professional electrician.

Disconnect power source.

Cover or shied any adjacent live components.

Ensure device cannot be switched on.

Check power supply is disconnected.

Connect  the  power  wire  with  the  sensor  according  to  the

connection-wire diagram.

Fix the sensor with inflated screw on the selected position

on the wall.

Switch on the power and test it.

CONNECTION-WIRE DIAGRAM

:

 

(See the right figure)     

SENSOR INFORMATION:

 

Height of installation: 1.8-2.5m 

Detection Distance: Max.18m 

TEST: 

Turn the SENS knob on the maximum (+).Turn the LUX knob

to  the  maximum  (sun).  Turn  the  TIME  knob  to  the  minimum

(10s).

Switch  on  the  power;  the  sensor  and  its  connected  lamp  will

have  no  signal  at  the  beginning.  After  Warm-up  30sec,  the

sensor  can  start  work  .If  the  sensor  receives  the  induction

signal,  the  lamp  will  turn  on.  While  there  is  no  another

induction signal any more, the load should stop working within

10sec

±

3sec and the lamp would turn off.

Turn  LUX  knob  on  the  minimum  (3).  If  the  ambient  light is more  than  3LUX,  the  sensor

would  not  work  and  the  lamp  stop  working  too.  If  the  ambient  light  is  less  than  3LUX

(darkness), the sensor would work. Under no induction signal condition, the sensor should

stop working within 10sec

±

3sec.

Note: when testing in daylight, please turn LUX knob to 

(sun) position, otherwise 

the sensor could not work! 

 

SOME PROBLEM AND SOLVED WAY: 

The load does not work:

a. Please check if the connection of power source and load is correct.

b. Please check if the load is good.

c. Please check if the settings of working light correspond to ambient light.

The sensitivity is poor:

a. Please check if there is any hindrance in front of the detector to affect it to receive

the signals. 

b. Please check if the ambient temperature is too high.

c. Please check if the induction signal source is in the detection field.

d. Please  check  if  the  installation  height  corresponds  to  the  height  required  in  the

instruction. 

e. Please check if the moving orientation is correct.

The sensor can not shut off the load automatically:

a. Please check if there is continual signal in the detection field.

b. Please check if the time delay is set to the maximum position

c. Please check if the power corresponds to the instruction.

Отзывы: