units, light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall
plants etc.
CONNECTION:
Warning. Danger of death through electric shock!
Must be installed by professional electrician.
Disconnect power source.
Cover or shied any adjacent live components.
Ensure device cannot be switched on.
Check power supply is disconnected.
Connect the power wire with the sensor according to the
connection-wire diagram.
Fix the sensor with inflated screw on the selected position
on the wall.
Switch on the power and test it.
CONNECTION-WIRE DIAGRAM
:
(See the right figure)
SENSOR INFORMATION:
Height of installation: 1.8-2.5m
Detection Distance: Max.18m
TEST:
Turn the SENS knob on the maximum (+).Turn the LUX knob
to the maximum (sun). Turn the TIME knob to the minimum
(10s).
Switch on the power; the sensor and its connected lamp will
have no signal at the beginning. After Warm-up 30sec, the
sensor can start work .If the sensor receives the induction
signal, the lamp will turn on. While there is no another
induction signal any more, the load should stop working within
10sec
±
3sec and the lamp would turn off.
Turn LUX knob on the minimum (3). If the ambient light is more than 3LUX, the sensor
would not work and the lamp stop working too. If the ambient light is less than 3LUX
(darkness), the sensor would work. Under no induction signal condition, the sensor should
stop working within 10sec
±
3sec.
Note: when testing in daylight, please turn LUX knob to
(sun) position, otherwise
the sensor could not work!
SOME PROBLEM AND SOLVED WAY:
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive
the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
c. Please check if the power corresponds to the instruction.