background image

USER MANUAL

RMSAL

RIFLE-MOUNTED SQUAD AIMING LASER

Содержание RMSAL

Страница 1: ...USER MANUAL RMSAL RIFLE MOUNTED SQUAD AIMING LASER...

Страница 2: ...on Regulations the International Economic Emergency Powers Act and various U S embargoes and sanctions AGM Global Vision products may not be exported re exported or transferred contrary to U S export...

Страница 3: ...lation and Mounting 10 2 3 Controls and Indicators 13 2 4 Operating Procedures 18 SECTION 3 MAINTENANCE INSTRUCTIONS 21 3 1 RMSAL Preventive Maintenance 21 3 2 User Level Troubleshooting 22 SECTION 4...

Страница 4: ...lasers at mirrors or highly reflective surfaces Do not point direct or shine the lasers into the eyes of other individuals CAUTION Verify that the device is OFF before installing a battery Do not dism...

Страница 5: ...iscrete intervals In addition the aiming lasers can be operated via user selectable switch in either a constant wave or 4 Hz pulsed mode The lasers can be activated either by remote switch assembly or...

Страница 6: ...LASER ON Indicator LED 4 Battery Cap and Battery Compartment One each 123A 3 0 VDC Lithium Battery 5 Ballistic Adjuster Elevation CW MPI up CCW MPI down 6 Ballistic Adjuster Tool threaded into backpl...

Страница 7: ...ER 21 Near IR Aimer POWER DIMMER 22 RMSAL Power Activation Button non remote NOTES The RMSAL is supplied with two 2 remote cable switches NOT SHOWN The black remote cable switch with BLACK button give...

Страница 8: ...number used to identify items in Figure 1 2 TABLE 1 2 STANDARD COMPONENTS ITEM DESCRIPTION 1 RMSAL Unit Assembly 2 CR123A Lithium Battery 3 Operator Manual 4 Soft Carrying Case 5 Remote Switch Assembl...

Страница 9: ...ht vision compatible mode Adjustable output power User selectable constant wave or pulsed modes of aiming lasers Two tactical remote switches including SAFETY remote switch Aiming lasers are co bore s...

Страница 10: ...gh magnified optics such as binoculars or telescopes Do not point the lasers at mirrors or highly reflective surfaces Do not point direct or shine the lasers into the eyes of other individuals CAUTION...

Страница 11: ...Stop turning the cam CCW when it reaches the end of it travel and you meet resistance Wrap the fixed jaw over the weapon rail center the recoil stop in a recoil groove and then tighten the translating...

Страница 12: ...button will remain in eye safe operational mode until such time as the BLACK Tactical remote switch is installed which then automatically resets the power circuits for full output power range access...

Страница 13: ...tch assembly is activated or the integral FIRE button located on the top of the RMSAL is pushed Note that when the RMSAL is positioned on the weapon rail at the 9 o clock position the stabilizing hand...

Страница 14: ...M IR ILLUM Both Near IR Aiming Laser and near IR Illuminator emit together The dual operation of the near IR aiming laser and Illuminator permit the target to be flushed out while the aiming laser dir...

Страница 15: ...on is labeled with the following icon _____ _____ _____ Note that the pulse selection button does NOT cause the near IR illuminator to pulse This feature is particularly useful when working in two man...

Страница 16: ...ety monitors There are two 2 light emitting diodes LED on the rear bulkhead of the RMSAL The first is a bi color LED labeled BATT that has two functions The first is to warn the operator that the batt...

Страница 17: ...mode 2 3 7 BALLISTIC ADJUSTERS Ballistic adjusters on the RMSAL employ a novel departure from the standard contemporary designs in creating a weapon bore sighted laser First the ballistic adjuster bo...

Страница 18: ...quipment in order to boresight beware of reflections from optical surfaces To boresight the RMSAL 1 Locate a target at the fire adjustment range 25 m 2 Take aim at the center of the target using the w...

Страница 19: ...y orientation Install battery cap 2 If you are operating the device using limited laser output to 600 W Class I for eye safe applications such as initial operator or force on force exercises use the B...

Страница 20: ...another operation mode turn the switch to the desired position and reactivate the laser s by pushing FIRE button 2 4 3 CONSTANT WAVE PULSE WAVE APPLICATIONS To change the pulse mode of the aiming lase...

Страница 21: ...bserved to be dried out then the O ring should be replaced If the battery cap is bent or scratched scarred in the O ring seat area then it should be replaced Periodically lubricate all O rings with fl...

Страница 22: ...authority within the unit or transfer to a more sophisticated maintenance and repair level TABLE 4 1 RMSAL USER LEVEL DIAGNOSES AND TROUBLESHOOTING ITEM MALFUNCTION TEST INSPECTION CORRECTIVE ACTION 1...

Страница 23: ...urn system back on and check power range adjustments 4 Aiming beams do not move a Check adjusters If dirty clean as needed If damaged return to Unit Level Maintenance 5 Remote Switch Inoperable but FI...

Страница 24: ...oper storage or improper operation of the device including use in conjunction with equipment that is electrically or mechanically incompatible with or of inferior quality to the product as well as fai...

Страница 25: ...oration s service center at the address listed above All merchandise must be fully insured with the correct postage AGM Global Vision will not be responsible for improper postage or merchandise that b...

Страница 26: ...mW Operating Distance 25 m in direct sunlight Visible Beam Divergence 0 5 mRad Visible Wavelength Red 605 nm 665 nm Green 500 nm 530 nm IR Illuminator Specification IR Class IIIb near IR IR Output 50...

Страница 27: ...bel Mode Selection Knob 7 Lens Cap Near IR Illuminator 8 Lens Cap Visible near IR Aiming Laser Port 9 Dual Lanyard Assembly illuminator aiming laser port 10 Remote Switch Assembly Tactical Full Access...

Страница 28: ...ain Street PO Box 962 Springerville AZ 85938 USA Tel 1 928 333 4300 Fax 1 480 393 4882 info agmglobalvision com www agmglobalvision com EUROPEAN OFFICE Andrey Lyapchev 7 Sofia P C 1756 Bulgaria Tel 44...

Отзывы: