IMPORTANT SAFETY INFORMATION ABOUT
PROPANE (LP) GAS
A self contained LP-gas cylinder for use with this appliance must have a capacity of 20 lbs. and must
be equipped with a Type 1 connector and an OPD (overfill protection device). See Figure 1.
The LP-gas supply cylinder to be used must be constructed and marked in accordance with the
specification for LP-gas cylinders of the U.S. Department of Transportation (DOT) or the National
Standard of Canada,
CAN/CSA-B339, Cylinder, Sphere and Tubes for the Transportation of
Dangerous Goods
.
z
The cylinder supply system must be arranged for vapor withdrawal.
z
The cylinder used must include a collar to protect the cylinder valve.
z
This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a
building, garage or any other enclosed space.
z
When this appliance is not is use, the gas must be turned off at the supply cylinder.
z
Storage of this appliance indoors is permissible only if the cylinder is disconnected and
removed from the appliance.
z
Cylinders must be stored outdoors in a well-ventilated area out of the reach of
children .Disconnected cylinders must have threaded valve plugs tightly installed and must not
be stored in a building, garage or any other enclosed areas.
CSA (Canadian Standards Association) certified to ANSI Z21.97•CSA 2.41-2012 “ Outdoor
Decorative Gas Appliances”. The gas hose is routed through a “U” bolt to prevent the hose from
coming in contact with the burner. DO NOT remove the hose from the “U” bolt. See Figure 2.
Figure
1
Figure
2
SPECIFICATIONS
INPUT
40,000 Btu/hr
30,000 Btu/hr Low fire
Propane Regulator Pressure
11 inches water column
Natural Gas Minimum Inlet
Pressure
7 inches water column
Clearances to combustible surfaces
Sides 24in./61cm
Top: 72 in. / 183 cm
THE UNIT HAS BEEN PRE-ASSEMBLED BY MANUFACTURER AND DOES NOT
REQUIRE ASSEMBLY BY CUSTOMER.
4