IMPORTANT SAFETY INFORMATION ABOUT   

PROPANE (LP) GAS 

A self contained LP-gas cylinder for use with this appliance must have a capacity of 20 lbs. and must 
be equipped with a Type 1 connector and an OPD (overfill protection device). See Figure 1. 
The LP-gas supply cylinder to be used must be constructed and marked in accordance with the 
specification for LP-gas cylinders of the U.S. Department of Transportation (DOT) or the National 
Standard of Canada, 

CAN/CSA-B339, Cylinder, Sphere and Tubes for the Transportation of 

Dangerous Goods

z

 

The cylinder supply system must be arranged for vapor withdrawal. 

z

 

The cylinder used must include a collar to protect the cylinder valve. 

z

 

This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a 
building, garage or any other enclosed space. 

z

 

When this appliance is not is use, the gas must be turned off at the supply cylinder. 

z

 

Storage of this appliance indoors is permissible only if the cylinder is disconnected and 
removed from the appliance. 

z

 

Cylinders must be stored outdoors in a well-ventilated area out of the reach of 
children .Disconnected cylinders must have threaded valve plugs tightly installed and must not 
be stored in a building, garage or any other enclosed areas. 

CSA (Canadian Standards Association) certified to ANSI Z21.97•CSA 2.41-2012 “ Outdoor 

Decorative Gas Appliances”.  The gas hose is routed through a “U” bolt to prevent the hose from 

coming in contact with the burner.    DO NOT remove the hose from the “U” bolt.    See Figure 2. 

                         

 

Figure 

       Figure 

 

SPECIFICATIONS 

INPUT 

40,000 Btu/hr 

30,000 Btu/hr Low fire 

Propane Regulator Pressure 

11 inches water column 

 

Natural Gas Minimum Inlet 

Pressure 

7 inches water column 

 

Clearances to combustible surfaces 

Sides      24in./61cm 

Top: 72 in. / 183 cm 

 

THE UNIT HAS BEEN PRE-ASSEMBLED BY MANUFACTURER AND DOES NOT 

REQUIRE ASSEMBLY BY CUSTOMER. 

 

 

Содержание DRC02200

Страница 1: ...ent alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment FOR USE...

Страница 2: ...OF CONTENTS Important Safety Information 3 Information about Propane 4 Specifications 4 Installation 5 Natural Gas Conversion 6 Lighting Instructions 8 Maintenance 8 Batteries 9 Parts List 9 Warranty...

Страница 3: ...near the appliance Clothing or other flammable material should not be hung from the appliance or placed on or near the appliance Any screen or guard removed for servicing an appliance must be replaced...

Страница 4: ...ance is not is use the gas must be turned off at the supply cylinder z Storage of this appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance z Cylinders...

Страница 5: ...able base After making any necessary adjustments to the alignment of the natural stone table top and the table base use four bolts and washers as shown in Fig 3 Guide the bolts through hole in the tab...

Страница 6: ...ckwise to the OFF position Open the tank valve Apply a solution of soapy water to the tank regulator connection and to the valve hose connection to check for leaks If soap bubbles continue to form the...

Страница 7: ...ersion label on the rating plate as shown in Fig 10 Metal Rating Plate Conversion Label Figure 10 Conversion Label 7 Serial Number _________________ Model Number 98910 CAUTION The gas pressure regulat...

Страница 8: ...ote If the fire does not light turn the knob to the OFF position and wait five 5 minutes before trying again 3 To turn down the flame push the control knob in slightly and turn to the Medium medium fl...

Страница 9: ...es one AAA size battery See Fig 13 Figure 13 Parts List Part Number Description FP0002 LAVA ROCKS FP0003 ELECTRODE FP0004 THERMOCOUPLE FP0006 IGNITION MODULE FP0008 NATURAL GAS FLEXIBLE CONNECTION HOS...

Страница 10: ...to the exclusions set forth above In addition the following are excluded from coverage under this warranty any item used for commercial contract or any other non residential purpose clearance items d...

Отзывы: