Notice

2

Safety Summary

Technology Licenses

The material contained in this document is provided 
“as is,” and is subject to being changed, without 
notice, in future editions. Further, to the maximum 
extent permitted by applicable law, Agilent disclaims 
all warranties, either express or implied, with regard 
to this manual and any information contained herein,
including but not limited to the implied warranties of 
merchantability and fitness for a particular purpose. 
Agilent shall not be liable for errors or for incidental 
or consequential damages in connection with the 
furnishing, use or performance of this document or 
of any information contained herein. Should Agilent 
and the user have a separate written agreement with 
warranty terms covering the material in this document 
that conflict with these terms, the warranty terms in 
the separate agreement shall control.

Restricted Rights Legend

Services and Support

Any adjustment, maintenance, or repair of this 

product must be performed by qualified personnel. 

Contact your customer engineer through your local 

Agilent Technologies Service Center. You can find 

a list of local service representatives on the Web at:

http://www.agilent.com/find/techsupport

Operating personnel must not remove instrument 
covers. Component replacement and internal 
adjustments must be made only by qualified 
personnel. 
Instruments that appear damaged or defective 
should be made inoperative and secured against 
unintended operation until they can be repaired by 
qualified service personnel.

The following general safety precautions must be 
observed during all phases of operation of this 
instrument. Failure to comply with these precautions 
or with specific warnings elsewhere in this manual 
violates safety standards of design, manufacture, 
and intended use of the instrument.

Agilent Technologies Inc. assumes no liability for 
the customer's failure to comply with these 
requirements.

Before operation, review the instrument and manual 
for safety markings and instructions. You must follow 
these to ensure safe operation and to maintain the 
instrument in safe condition.

This product is a Safety Class 1 instrument 
(provided with a protective earth terminal). 

The protective features of this product may be 

impaired if it is used in a manner not specified in 

the operation instructions.

All Light Emitting Diodes (LEDs) used in this 

product are Class 1 LEDs as per IEC 60825-1.

Environmental Conditions

Verify that all safety precautions are taken.

The power cable inlet of the instrument 

serves as a device to disconnect from the 

mains in case of hazard. 

The instrument must be positioned so that 

the operator can easily access the power 

cable inlet. When the instrument is rack-

mounted the rack must be provided with 

an easily accessible mains switch.

Before Applying Power

To minimize shock hazard, the instrument chassis 
and cover must be connected to an electrical 
protective earth ground. The instrument must be 
connected to the ac power mains through a 
grounded power cable, with the ground wire firmly 
connected to an electrical ground (safety ground) 
at the power outlet. Any interruption of the 
protective (grounding) conductor or disconnection 
of the protective earth terminal will cause a 
potential shock hazard that could result in 
personal injury.

Do not operate the instrument in the presence of 

flammable gases or fumes.

Do Not Operate in an Explosive Atmosphere

The hardware and/or software described in this 

document are furnished under a license and may 

be used or copied only in accordance with 

terms of such license.

Warranty

Revision 3.0, January 2010
Manual Part Number
N4916A-91010
Printed in Germany
Agilent Technologies, Deutschland GmbH
Herrenberger Str. 130
71034 Boeblingen, Germany

Revision

© Agilent Technologies, Inc. 2010

Copyright

General Safety Precautions

General

Ground the Instrument

This instrument is intended for indoor use in an
installation category II, pollution degree 
2 environment. It is designed to operate within 
a temperature range of 5 – 40 °C (40 – 105 °F)
at a maximum relative humidity of 95% and 
at altitudes of up to 2000 meters.

Refer to the specifications tables for the ac mains 
voltage requirements and ambient operating 
temperature range.

Do Not Remove the Instrument Cover

U.S. Government Restricted Rights.  

Software and technical data rights granted to 

the federal government include only those rights 

customarily provided to end user customers. 

Agilent provides this customary commercial license 

in Software and technical data pursuant to FAR 12.211 

(Technical Data) and 12.212 (Computer Software) and, 

for the Department of Defense, DFARS 252.227-7015 

(Technical Data - Commercial Items) and 

DFARS 227.7202-3 (Rights in Commercial Computer 

Software or Computer Software Documentation).

Содержание N4916A

Страница 1: ...r to the Online Help of your High Performance Serial BERT N4903A B or Pulse Data Generator 81141 42A The Help also offers printable versions of the User Guide and the Programming Guide You only need a few minutes to get started with the N4916A This Getting Started Brochure helps you to quickly install and check the instrument ...

Страница 2: ... specified in the operation instructions All Light Emitting Diodes LEDs used in this product are Class 1 LEDs as per IEC 60825 1 Environmental Conditions Verify that all safety precautions are taken The power cable inlet of the instrument serves as a device to disconnect from the mains in case of hazard The instrument must be positioned so that the operator can easily access the power cable inlet ...

Страница 3: ... the PG that are not used in your test setup must be terminated with 50 Ohm The instrument can operate from any single phase AC power source supplying 100 240 V in the frequency range from 50 60 Hz The maximum power consumption is 170 VA The power supply automatically adapts to the applied AC power Auto Selection and monitors the AC power range The mains plug can only be inserted in a socket outle...

Страница 4: ...t IO Libraries Suite is M 01 You can use IO Config for configuring the N4916A If you see this icon the revision of the Agilent IO Libraries Suite is 14 1 or later IO Control IO Control You may wish to connect a keyboard and mouse to your Serial BERT N4903A B or Pulse Data Generator 81141 42A This is not mandatory but convenient and should be done when the instrument is switched off 1 Open the Util...

Страница 5: ...6A and one of the rear USB ports of your N4903A B or Pulse Data Generator 81141 42A 3 When you connect the N4916A for the first time the Windows Found New Hardware Wizard appears and asks wether he should connect to Windows Update Answer No 4 Click Next until the wizard finishes 5 Windows will automatically identify the N4916A as a USB Test and Measurement Device The necessary USB driver is part o...

Страница 6: ...UsbDevice1 is the default alias name 2 Click Change Properties and change the alias name to D4916 This is the alias used by the software 3 After clicking OK the Agilent Connection Expert shows a window like the following 4 In this example we use the Agilent Connection Expert If your N4903A B or 81141 42A uses revision M 01 of the Agilent IO Libraries Suite you can run IO Config for the same purpos...

Страница 7: ...r 81141 42A and the N4916A You can set the de emphasis value between 0 and 12 dB 4 The Config window displays a list of instruments externally connected to the N4903B 3 Press Enable to activate the connection between the N4903B and the N4916A 4Switch to PG Setup menu and click Data Output to access Data Output window 5 You can set the de emphasis value between 8 to 0 dB Use a 2 4 mm cable m m and ...

Страница 8: ... 4 The general approach shown here is using an oscilloscope If you have connected the N4916A to a High Performance Serial BERT N4903A B you can also use the error detector For details see the Help and the User Guide Choose a suitable pattern e g PRBS and start the pattern generator 5 After some adjustments of the scope you will see a display like the following 6 In case of problems please refer to...