Agilent Technologies LogicWave Скачать руководство пользователя страница 25

Agilent Technologies
P.O. Box 2197
1900 Garden of the Gods Road
Colorado Springs, CO 80901-2197, U.S.A.

© Copyright Agilent Technologies 
1994-2000
All Rights Reserved.

Reproduction, adaptation, or 
translation without prior written 
permission is prohibited, except 
as allowed under the copyright 
laws.

Restricted Rights Legend

Use, duplication, or disclosure by 
the U.S. Government is subject to 
restrictions set forth in 
subparagraph (C) (1) (ii) of the 
Rights in Technical Data and 
Computer Software Clause in 
DFARS 252.227-7013.  Agilent 
Technologies, Inc., 3000 Hanover 
Street, Palo Alto, CA 94304 U.S.A.  
Rights for non-DOD U.S. 
Government Departments and 
Agencies are set forth in FAR 
52.227-19 (c) (1,2).

Document Warranty

The information contained in this 
document is subject to change 
without notice.

Agilent Technologies makes 
no warranty of any kind with 
regard to this material, 
including, but not limited to, 
the implied warranties of 
merchantability or fitness for 
a particular purpose.

Agilent Technologies shall not be 
liable for errors contained herein 
or for damages in connection with 
the furnishing, performance, or 
use of this material.

Safety

This apparatus has been designed 
and tested in accordance with 
IEC Publication 1010, Safety 
Requirements for Measuring 
Apparatus, and has been supplied 
in a safe condition.  This is a 
Safety Class I instrument 
(provided with terminal for 
protective earthing).  Before 
applying power, verify that the 
correct safety precautions are 
taken (see the following 
warnings).  In addition, note the 
external markings on the 
instrument that are described 
under "Safety Symbols."

Warning

• Before turning on the 
instrument, you must connect the 
protective earth terminal of the 
instrument to the protective 
conductor of the (mains) power 
cord. The mains plug shall only be 
inserted in a socket outlet 
provided with a protective earth 
contact. You must not negate the 
protective action by using an 
extension cord (power cable) 
without a protective conductor 
(grounding).  Grounding one 
conductor of a two-conductor 
outlet is not sufficient protection.

• Only fuses with the required 
rated current, voltage, and 
specified type (normal blow, time 
delay, etc.) should be used.  Do 
not use repaired fuses or short-
circuited fuseholders.  To do so 
could cause a shock of fire hazard.

• Service instructions are for 
trained service personnel. To 
avoid dangerous electric shock, 
do not perform any service unless 
qualified to do so.  Do not attempt 
internal service or adjustment 
unless another person, capable of 
rendering first aid and 
resuscitation, is present.

• If you energize this instrument 
by an auto transformer (for 
voltage reduction), make sure the 
common terminal is connected to 
the earth terminal of the power 
source.

• Whenever it is likely that the 
ground protection is impaired, 
you must make the instrument 
inoperative and secure it against 
any unintended operation.

• Do not operate the instrument 
in the presence of flammable 
gasses or fumes.  Operation of any 
electrical instrument in such an 
environment constitutes a definite 
safety hazard.

• Do not install substitute parts or 
perform any unauthorized 
modification to the instrument.

• Capacitors inside the 
instrument may retain a charge 
even if the instrument is 
disconnected from its source of 
supply.

Safety Symbols

Instruction manual symbol:  the 
product is marked with this 
symbol when it is necessary for 
you to refer to the instruction 
manual in order to protect against 
damage to the product.

Hazardous voltage symbol.

Earth terminal symbol: Used to 
indicate a circuit common 
connected to grounded chassis.

WARNING

The Warning sign denotes a 
hazard.  It calls attention to a 
procedure, practice, or the like, 
which, if not correctly performed 
or adhered to, could result in 
personal injury.  Do not proceed 
beyond a Warning sign until the 
indicated conditions are fully 
understood and met.

CAUTION

The Caution sign denotes a 
hazard.  It calls attention to an 
operating procedure, practice, or 
the like, which, if not correctly 
performed or adhered to, could 
result in damage to or destruction 
of part or all of the product.  Do 
not proceed beyond a Caution 
symbol until the indicated 
conditions are fully understood or 
met.

!

Содержание LogicWave

Страница 1: ...gicWave Installation Guide Publication number E9340 97002 December 2000 For Safety information Warranties and Regulatory information see the pages behind the index Copyright Agilent Technologies 1994 2000 All Rights Reserved ...

Страница 2: ...In This Book This book Shows how to install and care for the LogicWave logic analyzer Describes the LogicWave specifications and characteristics See Also The online help for information on using LogicWave ...

Страница 3: ...ep 4 Install software 10 Step 5 Start the LogicWave user interface 11 Step 6 Connect probe cables 13 Step 7 Probe the device under test 14 Step 8 Make measurements 15 Caring for LogicWave 16 To clean the instrument 16 2 Specifications and Characteristics Specifications 19 Characteristics 20 General 20 Timing Analysis 20 State Analysis 21 Triggering 21 Probes 21 Operating Environment 22 ...

Страница 4: ...4 Contents ...

Страница 5: ...5 1 Setting Up LogicWave Shows how to install the Agilent Technologies LogicWave logic analyzer and provides instructions on caring for the instrument ...

Страница 6: ...user interface requires a host computer PC with the following characteristics or better Pentium 90 MHz Windows 95 98 NT 2000 16MB RAM 10MB available space on the hard disk drive Available parallel port no pass through devices installed Available LPT1 peripheral device designator The host computer PC running the logic analyzer interface can be either powered on or off The interface software is inst...

Страница 7: ...Apply power to the PC if it is not turned on To ensure the PC s parallel port is properly configured interrupt the PC s boot process by pressing F2 on the keyboard Scroll down to the parallel port configuration and observe the current parallel port data transfer mode Ensure either Enhanced Capabilities Port ECP Byte or Nibble mode is selected Enhanced Parallel Port EPP mode will not work If none o...

Страница 8: ...TION Use only the supplied power supply HP F1044B and cord Failure to use the proper power supply could result in equipment damage 1 Connect the power cord to the power supply input 2 Connect the power supply output cable to the power input connector on the rear panel of the logic analyzer ...

Страница 9: ...alling LogicWave Step 3 Turn on power CAUTION Do not block the air intake vents on the bottom of the logic analyzer 1 Turn the power switch to the on 1 position 2 Wait approximately 15 seconds for the logic analyzer to power up and settle ...

Страница 10: ...10 Chapter 1 Setting Up LogicWave Installing LogicWave Step 4 Install software See Also Refer to the instructions on the installation CD ...

Страница 11: ...tion from the Start menu or using a shortcut 2 Observe the start dialog If the LogicWave was found a self test will auto initiate and the LogicWave interface indicates Connected 3 If automatic connection to the logic analyzer fails then a Device Connection Failed dialog box will appear Select Search for the device then select Continue ...

Страница 12: ...etting Up LogicWave Installing LogicWave 4 The LogicWave Communication Setup window will appear Select the E9340A device then select Connect 5 At the Welcome window select OK 6 In the Setup Properties dialog click OK ...

Страница 13: ...13 Chapter 1 Setting Up LogicWave Installing LogicWave Step 6 Connect probe cables CAUTION Use only the probe cable that is provided ...

Страница 14: ...14 Chapter 1 Setting Up LogicWave Installing LogicWave Step 7 Probe the device under test ...

Страница 15: ...15 Chapter 1 Setting Up LogicWave Installing LogicWave Step 8 Make measurements See Also Refer to the online help for more information on using LogicWave ...

Страница 16: ...g for LogicWave Caring for LogicWave This section provides instructions on caring for the LogicWave logic analyzer To clean the instrument With the logic analyzer turned off and unplugged use mild detergent and water to clean the instrument ...

Страница 17: ...17 2 Specifications and Characteristics Describes the specifications characteristics and other characteristics and requirements of the Agilent Technologies LogicWave E9340A logic analyzer ...

Страница 18: ...ecifications by comparing measured parameters against a pass fail limit The pass fail limit is the specification less any required guardband The term calibration refers to the process of measuring parameters and referencing the measurement to a calibration standard rather than the process of adjusting products for optimal performance What is a Characteristic Characteristics describe product perfor...

Страница 19: ...19 Chapter 2 Specifications and Characteristics Specifications Specifications 0D LPXP VWDWH FORFN 0 7KUHVKROG DFFXUDF P9 RI WKUHVKROG VHWWLQJ 6HWXS KROG WLPH QV IL HG ...

Страница 20: ...WHU VXSSRUWHG E WKH 3 3URELQJ NRKPV S LPHQVLRQV FP HLJKW SRXQGV NJ 2 3RUWV QKDQFHG 3DUDOOHO FRQQHFWLRQ WR 3 IRU IDVW GLVSOD XSGDWH UDWHV 7ULJJHU 1 287 1 6XSSRUWHG ILOH IRUPDWV IRU VFUHHQ VKRWV 8VH WUO OW 3ULQW6FUHHQ WR FUHDWH ELWPDS RQILJXUDWLRQ DQG GDWD ILOHV QFRGHG LQ ELQDU IRUPDW VWRUHG WR RU ORDGHG IURP KRVW 3 FDQ H SRUW DFTXLUHG GDWD WR DQ 6 IRUPDWWHG ILOH 0D LPXP SRZHU VXSSO YROWDJH 9 7 7 0D...

Страница 21: ...V ORFN TXDOLILHUV VHWXS KROG QV IL HG 6HTXHQFHU VSHHG 0 PD LPXP 6WDWH VHTXHQFH OHYHOV 7LPLQJ VHTXHQFH OHYHOV 3RUW Q GHOD QV EHWZHHQ ULVLQJ HGJH RQ 3RUW Q 1 DQG GRQ W FDUH ORJLF DQDO HU WULJJHU 3RUW 2XW GHOD QV EHWZHHQ ORJLF DQDO HU WULJJHU DQG ULVLQJ HGJH RQ 3RUW 2XW 1 QSXW UHVLVWDQFH NRKP 3DUDVLWLF WLS FDSDFLWDQFH S 0LQLPXP LQSXW YROWDJH VZLQJ P9 SHDN WR SHDN 7KUHVKROG DFFXUDF P9 RI WKUHVKROG VHW...

Страница 22: ... Operating Environment 7HPSHUDWXUH QVWUXPHQW WR WR LVN PHGLD WR WR XPLGLW 8S WR UHODWLYH KXPLGLW DW OWLWXGH P IW QGRRU XVH RQO 3ROOXWLRQ GHJUHH 1RUPDOO RQO GU QRQ FRQGXFWLYH SROOXWLRQ RFFXUV 2FFDVLRQDOO D WHPSRUDU FRQGXFWLYLW FDXVHG E FRQGHQVDWLRQ PXVW EH H SHFWHG ...

Страница 23: ... 1982 A1 1990 EN 60555 3 1987 A1 1991 IEC 801 2 1991 EN 50082 1 1992 4 kV CD 8 kV AD IEC 801 3 1984 EN 50082 1 1992 3 V m 1kHz 80 AM 27 1000 MHz IEC 801 4 1998 EN 50082 1 1992 0 5 kV Sig Lines 1 kV Power Lines Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC and carries the CE marking accordingly T...

Страница 24: ...89 336 EEC Emissions EN55011 CISPR 11 ISM Group 1 Class A equipment IEC 555 2 and IEC 555 3 Immunity EN50082 1 Code1 IEC 801 2 ESD 8kV AD IEC 801 3 Rad 3 V m IEC 801 4 EFT 1kV 3 1 1 1 Performance Codes 1 PASS Normal operation no effect 2 PASS Temporary degradation self recoverable 3 PASS Temporary degradation operator intervention required 4 FAIL Not recoverable component damage ...

Страница 25: ...ding one conductor of a two conductor outlet is not sufficient protection Only fuses with the required rated current voltage and specified type normal blow time delay etc should be used Do not use repaired fuses or short circuited fuseholders To do so could cause a shock of fire hazard Service instructions are for trained service personnel To avoid dangerous electric shock do not perform any servi...

Страница 26: ...her warranty is expressed or implied Agilent Technologies specifically disclaims the implied warranties of merchantability or fitness for a particular purpose Exclusive Remedies The remedies providedhereinare the buyer s sole and exclusive remedies Agilent Technologies shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any othe...

Отзывы: