![Agilent Technologies J-BERT N4903 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/agilent-technologies/j-bert-n4903/j-bert-n4903_user-manual_2868694015.webp)
then you must know the expected output pattern and select it as the
error detector reference pattern.
•
What logic family is your device compatible with?
The pattern generator has preset voltage levels to work with ECL,
SCFL, LVPECL, LVDS, and CML. Be sure to select the correct logic
family. See
“Understanding how the Serial BERT Uses Logic Families
•
What is the input termination voltage of your device?
Make sure it is the same voltage as displayed in the pattern generator
termination list.
•
What termination voltage is the output of your device designed to
work with?
Make sure it is set for the error detector's data port termination. See
“Data In Port Termination” on page 113
•
What bit rate do you need to test your device at?
The Serial BERT allows you to run tests from 150 Mb/s up to 12.5Gb/
s (depending on the options with which you bought the instrument).
See
“Error Detector Bit Rate” on page 122
•
Does your device require differential inputs?
As complementary outputs, Data/Clock Out and Data/Clock Out may
satisfy this requirement. See
Differential Inputs” on page 18
.
•
Is the output of your device noisy or very small in amplitude?
You may need to manually set up a sampling point. See
Point Setup - Concepts ” on page 126
•
Do you want to check the BER in bursts (for example, for loop testing
applications)?
The Serial BERT provides capabilities that help you set up and run
burst tests. See
“Introduction to Burst Sync Mode” on page 144
.
•
Are you aware of how the sync mode setting can affect the way errors
are measured and displayed?
“What Type of Synchronization Should You Use?” on page 141
.
Test Times and Confidence Levels
A true BER measurement must be statistically valid. Because it is not
possible to predict with certainty when errors will occur, your device
must be tested long enough to have confidence in its BER performance.
The table below lists the test times required for different BERs at
specific bit rates.
Planning the Test
1
Agilent J-BERT N4903 High-Performance Serial BERT
15
Содержание J-BERT N4903
Страница 1: ...S Agilent J BERT N4903 High Performance Serial BERT User Guide s Agilent Technologies...
Страница 68: ...2 Setting up Patterns 68 Agilent J BERT N4903 High Performance Serial BERT...
Страница 158: ...4 Setting up the Error Detector 158 Agilent J BERT N4903 High Performance Serial BERT...
Страница 314: ...6 Evaluating Results 314 Agilent J BERT N4903 High Performance Serial BERT...
Страница 374: ...7 Jitter Tolerance Tests 374 Agilent J BERT N4903 High Performance Serial BERT...
Страница 394: ...8 Solving Problems 394 Agilent J BERT N4903 High Performance Serial BERT...
Страница 434: ...Index 434 Agilent J BERT N4903 High Performance Serial BERT...