Mixed-Signal Oscilloscope 
(Logic  Analyzer)  Demonstration                                       

16 integrated, time-aligned 
channels • 2 GSa/s  • 128 Mpts per channel

1. 

Connect probes and ground leads 
from channel 1 and channel 2 to 
corresponding test points provided.

2. 

Connect MSO cable from front of scope 
to connector on demo board..

3. 

Turn the mode select knob to position 
6 (SPI) 

4. Press 

Default Setup

5. Press 

AutoScale

 to get the following 

display of analog and digital channels:

Quick demo

Protocol  Analyzer  Demonstration                                      

Time-aligned physical and protocol views • 
Broadest support available •Industry’s only 
multi-tab viewer on scope

Quick demo

1. Press 

Default Setup.

2. Press 

AutoScale

.

3. Select 

Setup

 tab at the top of the screen 

and select 

Serial Decode

.

4. Choose 

Serial Decode

 from the menu 

and select USB 2.0.  Check the 

Show 

Decode

 box and press 

AutoSetup

 to get 

the following display.

5. 

Note that the payload value (which 
contains coordinate information) changes 
as you move the mouse. The blue cursor 
on the waveform display is time-aligned 
to the blue highlighted line in the decode 
display. 

6. 

Now let’s set up to trigger on a mouse 
move. Highlight the 

Trigger

 tab at the top 

of the screen and select 

Setup Trigger.

 In 

the 

Type

 menu choose 

Data.

 Select the 

Payload

 tab in the decode view and note 

that the scope triggers and displays the 
data each time the mouse is moved.

6. 

Note that the digital channels can be 
grouped into buses if desired. Trigger 
and decode are available across any 
combination of analog and digital signals, 
and the display is totally time-aligned.

7. Highlight 

the 

Setup

 tab at the top of 

the screen and select 

Acquisition.

  

Select 

Segmented

 under Sampling 

Mode.  Manually enter 

100

 for the # of 

segments. Close the box and press 

Run.

8. 

After all 100 segments are acquired, 
use the 

Play

 menu at the bottom of the 

screen to demonstrate stepping through 
the acquisitions to note the differences.

For more information on Agilent Technologies’ 
products, applications or services, please 
contact your local Agilent office. The 
complete list is available at:

www.agilent.com/find/contactus

Americas

Canada (877) 

894-4414 

Latin America 

305 269 7500

United States 

(800) 829-4444

Asia Pacifi c

Australia  

1 800 629 485

China 

800 810 0189

Hong Kong  

800 938 693

India  

1 800 112 929

Japan 

0120 (421) 345

Korea 

080 769 0800

Malaysia  

1 800 888 848

Singapore  

1 800 375 8100

Taiwan 

0800 047 866

Thailand  

1 800 226 008 

Europe & Middle East

Austria 

43 (0) 1 360 277 1571

Belgium  

32 (0) 2 404 93 40 

Denmark 

45 70 13 15 15

Finland 

358 (0) 10 855 2100

France 

0825 010 700*

 *0.125 

€/minute

Germany 

49 (0) 7031 464 6333 

Ireland 

1890 924 204

Israel 

972-3-9288-504/544

Italy 

39 02 92 60 8484

Netherlands 

31 (0) 20 547 2111

Spain 

34 (91) 631 3300

Sweden 

0200-88 22 55

Switzerland  

0800 80 53 53

United Kingdom 

44 (0) 118 9276201

Other European Countries:

www.agilent.com/find/contactus

 

Product specifications and descriptions in 
this document subject to change without 
notice.

October 1, 2009

© Agilent Technologies, Inc. 2011
Printed in USA, March 15, 2011

5990-3773EN

Отзывы: