www.agilent.com
www.agilent.com/find/9000
Mixed-Signal Oscilloscope
(Logic Analyzer) Demonstration
16 integrated, time-aligned
channels • 2 GSa/s • 128 Mpts per channel
1.
Connect probes and ground leads
from channel 1 and channel 2 to
corresponding test points provided.
2.
Connect MSO cable from front of scope
to connector on demo board..
3.
Turn the mode select knob to position
6 (SPI)
4. Press
Default Setup
5. Press
AutoScale
to get the following
display of analog and digital channels:
Quick demo
Protocol Analyzer Demonstration
Time-aligned physical and protocol views •
Broadest support available •Industry’s only
multi-tab viewer on scope
Quick demo
1. Press
Default Setup.
2. Press
AutoScale
.
3. Select
Setup
tab at the top of the screen
and select
Serial Decode
.
4. Choose
Serial Decode
from the menu
and select USB 2.0. Check the
Show
Decode
box and press
AutoSetup
to get
the following display.
5.
Note that the payload value (which
contains coordinate information) changes
as you move the mouse. The blue cursor
on the waveform display is time-aligned
to the blue highlighted line in the decode
display.
6.
Now let’s set up to trigger on a mouse
move. Highlight the
Trigger
tab at the top
of the screen and select
Setup Trigger.
In
the
Type
menu choose
Data.
Select the
Payload
tab in the decode view and note
that the scope triggers and displays the
data each time the mouse is moved.
6.
Note that the digital channels can be
grouped into buses if desired. Trigger
and decode are available across any
combination of analog and digital signals,
and the display is totally time-aligned.
7. Highlight
the
Setup
tab at the top of
the screen and select
Acquisition.
Select
Segmented
under Sampling
Mode. Manually enter
100
for the # of
segments. Close the box and press
Run.
8.
After all 100 segments are acquired,
use the
Play
menu at the bottom of the
screen to demonstrate stepping through
the acquisitions to note the differences.
For more information on Agilent Technologies’
products, applications or services, please
contact your local Agilent office. The
complete list is available at:
www.agilent.com/find/contactus
Americas
Canada (877)
894-4414
Latin America
305 269 7500
United States
(800) 829-4444
Asia Pacifi c
Australia
1 800 629 485
China
800 810 0189
Hong Kong
800 938 693
India
1 800 112 929
Japan
0120 (421) 345
Korea
080 769 0800
Malaysia
1 800 888 848
Singapore
1 800 375 8100
Taiwan
0800 047 866
Thailand
1 800 226 008
Europe & Middle East
Austria
43 (0) 1 360 277 1571
Belgium
32 (0) 2 404 93 40
Denmark
45 70 13 15 15
Finland
358 (0) 10 855 2100
France
0825 010 700*
*0.125
€/minute
Germany
49 (0) 7031 464 6333
Ireland
1890 924 204
Israel
972-3-9288-504/544
Italy
39 02 92 60 8484
Netherlands
31 (0) 20 547 2111
Spain
34 (91) 631 3300
Sweden
0200-88 22 55
Switzerland
0800 80 53 53
United Kingdom
44 (0) 118 9276201
Other European Countries:
www.agilent.com/find/contactus
Product specifications and descriptions in
this document subject to change without
notice.
October 1, 2009
© Agilent Technologies, Inc. 2011
Printed in USA, March 15, 2011
5990-3773EN