The Infi niium 9000 Series 
Oscilloscope Quick Demo 

9000 Series demo board, mouse and two passive probes required

Quick  demo                                                                                                                                            

Infiniium 9000 Series 

Designed to fi t your environment

  •  Biggest screen in class (15” XGA) 
  •  Touchscreen with 1024x768  

 

  resolution
 • Thin
  •  Light (26 lbs)
  •  Knob per channel
  •  Convenient USB and other  

 

  connectivity
  •  Quiet fans (30 db in front)   

 

 

3 instruments in 1 box

Scope: 

Powerful Infi niium features  

coupled with superior specs for 
precise signal representation.

Logic analyzer: 

 16 fully integrated 

digital channels to see critical data 
values and timing relationships

Protocol analyzer: 

World’s fi rst 

scope-based protocol viewer with 
multi-tab viewing to quickly drill down 
and move between protocol and 
physical layers.

Widest range of debug and 

 compliance apps:

  Tailor your  

 

  scope to simplify debug and 
  compliance testing today and  

 

  in the future with the industry’s  

 

  widest range of application software.

Oscilloscope Demonstration                                                                                                              

 600 MHz, 1 GHz, 2.5 GHz, 4 GHz Models • 20 Mpts – 1 Gpt Memory • 10- 20 GSa/s

4.  Drag and drop the rise time measurement  

icon onto the signal to demonstrate quick 
measurements.

5.  Expand the measurement tab window. 

Highlight the 

Measure

 menu at the top of  

the screen to illuminate the drop  
down menus and walk through some of 
the measurements Infi niium

 6.  Highlight the 

Analyze

 menu at the top  

of the screen to show rich feature set 
here also.

7. Highlight 

the 

Trigger

 menu at the top 

of the screen, click on setup trigger and 
point out trigger shortcuts and gallery.

8.   Then choose 

Infi niiScan

 and select 

Zone Qualify

 from the menu. Draw a box 

around area where signals occur when 
you move the mouse and select 

AND 

Must Intersect

 from the Zone 1 menu 

choice. Powerful hardware triggering 
combined with Infi niiScan event triggering 
makes for effi cient troubleshooting.

9. Highlight 

the 

Setup

 tab at the top of the 

screen and select 

Acquisition.

  Change 

the Analog Memory Depth setting to 

Manual

 and select 

Max.

 Close the setup 

screen and adjust the timebase to about 

1 ms/div

 to show multiple bursts on 

screen. 

10. Press the 

zoom

 button to see detail 

for one of the bursts. Responsive deep 
memory allows you to take advantage of 
your investment to zero in on the details 
when needed.

Engineered for the broadest 
measurement capability.

Connect channel 1 probe to red test point 
marked D+ and corresponding ground, 
connect channel 2 probe to red test point 
marked D- and corresponding ground. 
Mouse signal is passed through and 
acquired by scope. Move mouse and see 
transmission of USB packets with XY 
coordinates.

1.   Press 

Default Setup.

2.   Press 

AutoScale.

3.   Adjust timebase to about 10 us/div
 

and delay to get the following display of    

 USB 

signals. 

 

 