Agilent Technologies EXSLRSH110 Скачать руководство пользователя страница 13

SH-110 Exhaust Silencer Kit 

This page intentionally left blank.

Pg 3/3

  

 

 

 

 

 

 

 

 

 

 

 

 

               

Vacuum Products Division     

 

 

 

 

 

  

 

 

 

 

Request for Return Form

 

 

 

 

 

 

 

 

 

            (Health and Safety Certification)

Please use these Failure Mode to describe the concern about the product on Page 2.

TURBO PUMPS and TURBO CONTROLLERS

APPARENT DEFECT/MALFUNCTION

POSITION

PARAMETERS

- Does not start

- Noise

- Vertical  

Power:

Rotational Speed:

- Does not spin freely

- Vibrations

-Horizontal  

Current:

Inlet Pressure:

- Does not reach full speed

-Leak

-Upside-down  

Temp 1:

Foreline Pressure:

- Mechanical Contact

-Overtemperature

-Other:

Temp 2:

Purge flow:

- Cooling defective

-Clogging

………………….

OPERATING TIME:

ION PUMPS/CONTROLLERS   

        

 

         VALVES/COMPONENTS

- Bad feedthrough

- Poor vacuum

- Main seal leak

- Bellows leak

- Vacuum leak

- High voltage problem

- Solenoid failure

- Damaged flange

- Error code on display

- Other

- Damaged sealing area

-Other

LEAK DETECTORS   

        

 

 

         INSTRUMENTS

- Cannot calibrate

-No zero/high backround

- Gauge tube not working

- Display problem

- Vacuum system unstable

- Cannot reach test mode

- Communication failure

- Degas not working

- Failed to start

- Other

- Error code on display

 - Other

             SCROLL AND ROTARY VANE PUMPS 

 

 

        

         DIFFUSION PUMPS

- Pump doesn’t start

- Noisy pump (describe)

- Heater failure

 - Electrical problem

- Doesn’t reach vacuum

- Over temperature

- Doesn’t reach vacuum

- Cooling coil damage

- Pump seized

- Other

- Vacuum leak

- Other

Section 6) 

ADDITIONAL TERMS

Please read the terms and conditions below as they apply to all returns and are in addition to the Agilent 

Technologies Vacuum Product Division – Products and Services Terms of Sale. 

x

Customer is responsible for the freight charges for the returning product.  Return shipments must comply with all 
applicable 

Shipping Regulations

(IATA, DOT, etc.) and carrier requirements.

x

Customers receiving an Advance Exchange product agree to return the defective, rebuildable part to Agilent Technologies

within 15 business days

. Failure to do so, or returning a non-rebuildable part (crashed), will result in an invoice for the 

non-returned/non-rebuildable part.

x

Returns for credit toward the purchase of new or refurbished Products are subject to prior Agilent approval and may incur 
a restocking fee. Please reference the original purchase order number. 

x

Units returned for evaluation will be evaluated, and a quote for repair will be issued. If you choose to have the unit 
repaired, the cost of the evaluation will be deducted from the final repair pricing. A Purchase Order for the final repair price 
should be issued within 3 weeks of quotation date. Units without a Purchase Order for repair will be returned to the 
customer, and the evaluation fee will be invoiced. 

x

A Special Cleaning fee will apply to all exposed products per Section 4 of this document.

x

If requesting a calibration service, units must be functionally capable of being calibrated.

Содержание EXSLRSH110

Страница 1: ...D R A F T Vacuum Products Division SH 110 EXHAUST SILENCER KIT Part No 699904395 Rev A April 2008 INSTRUCTION MANUAL...

Страница 2: ...D R A F T Copyright 2008 Agilent Inc SH 110 Exhaust Silencer Kit...

Страница 3: ...except as stated herein Seller shall have no liability under any warranty express or implied either in fact or by operation of law statutory or otherwise Statements made by any person including repres...

Страница 4: ...SH 110 Exhaust Silencer Kit This page intentionally left blank D R A F T...

Страница 5: ...tion Before operating or servicing equipment read and thoroughly understand all operation maintenance manuals provided by Agilent Be aware of the hazards associated with this equipment know how to rec...

Страница 6: ...SH 110 Exhaust Silencer Kit This page intentionally left blank D R A F T...

Страница 7: ...nted at the exhaust of an SH 110 in the side position Table 1 1 breaks down the kit parts and quantities Replacement polyester filter element rated 99 efficient at the 5 micron particle size P N REPLS...

Страница 8: ...he 1 4 NPT barb and secure with a hose clamp 4 Connect the other end of the Tygon tubing to the hose 3 8 NPT barb belonging to the Resonator assembly and secure with a hose clamp 5 Connect the second...

Страница 9: ...ent of gases being pumped Instead route the pump exhaust to an appropriate collection system Figure 1 2 shows the kit dimensions Figure 1 2 SH 110 Silencer Filter Can Kit Dimensions Figure 1 3 SH 110...

Страница 10: ...ust silencer kit does not significantly influence the sound pressure when pumping at base pressure The kit s silencer resonator assembly mitigates exhaust pulsation noise in the most sensitive frequen...

Страница 11: ...core product e g inlet screens vent valves x Prior to shipment drain any oils or other liquids purge or flush all gasses and wipe off any excess residue x If ordering an Advance Exchange product pleas...

Страница 12: ...been exposed to any toxic or hazardous materials OR HAS pumped or been exposed to the following toxic or hazardous materials If this box is checked the following information must also be filled out C...

Страница 13: ...er Vacuum leak Other Section 6 ADDITIONAL TERMS Please read the terms and conditions below as they apply to all returns and are in addition to the Agilent Technologies Vacuum Product Division Products...

Страница 14: ...SH 110 Exhaust Silencer Kit This page intentionally left blank...

Страница 15: ......

Страница 16: ...y Agilent Technologies Vacuum Products Division via F lli Varian 54 10040 Leini Torino ITALY Tel 39 011 997 9111 Toll Free 00 800 234 234 00 Fax 39 011 997 9350 Japan Agilent Technologies Vacuum Produ...

Отзывы: