background image

©

 

2000 Agilent Technologies 

Automatic Barcode Reader

1

AGILENT TECHNOLOGIES

AGILENT 5DX SERIES II/2L/3

AUTOMATIC BARCODE READER

INSTALLATION AND OPERATION

PROCEDURES FOR THE MICROSCAN

IN-LINE BARCODE READER SUBSYSTEM

November 2000

Содержание E7242A

Страница 1: ...echnologies Automatic Barcode Reader 1 AGILENT TECHNOLOGIES AGILENT 5DX SERIES II 2L 3 AUTOMATIC BARCODE READER INSTALLATION AND OPERATION PROCEDURES FOR THE MICROSCAN IN LINE BARCODE READER SUBSYSTEM...

Страница 2: ...rve as a theory of operation or software implementation specification This manual has been designed to assist personnel in the installation and operation of the BCR subsystem for the AGILENT 5DX produ...

Страница 3: ...nnect the BCR components as shown in the diagram The AC power connection for the Power Supply is provide at the J Box mounted on the left rear corner of the AGILENT 5DX Main Cabinet on Series I throug...

Страница 4: ...ad towards the standard bar code label at a distance of about 2 0 50mm and verify that the raster scans across the length of the bar code label Also check the power status green indicator light is lit...

Страница 5: ...ensure that all cable connections are good If still failing try resetting the BCR head procedure on next page and test again If the BCR still cannot successfully scan any barcode you should replace th...

Страница 6: ...ow From the 5DX User Interface window select SYSTEM Quit from 5DX The stand alone configuration file should already be set for a Microscan 600 series scanner However if it is necessary to change the b...

Страница 7: ...oceed to the next step If an error mes sage is displayed re check the scnr cfg file for the correct setup 6 Verify BCR operation and alignment Position the scanner head towards the standard barcode la...

Страница 8: ...he user can specify an m parameter to operate the executable in manual mode In this mode a read cycle can only be generated by pressing the SPACE BAR This will allow the user to slowly control the ali...

Страница 9: ...nt Technologies Automatic Barcode Reader 9 Figure 9 ALIGNBCR Usage and Output for Manual Mode 8 Configure the Bar Code Reader from the Agilent 5DX User Interface Select System Sytem Access Configure 5...

Страница 10: ...der 10 Figure 10 Screen shot of Result of Step 8 9 Use the arrow key and select In Line Bar Code Reader Figure 11 Screen shot of result of Step 9 10 Configure the menu to use the barcode reader and ma...

Страница 11: ...hout the help of the customer The customer must provide the Serial Numbers for their boards panels to continue with the next step 11 Serial Numbers for loading CAD The customer must configure the Seri...

Страница 12: ...he Microscan BCR scanner 610 0018 to work in either Stand Alone mode or Multidrop mode To configure in the multidrop mode refer to Figure 13 and follow the procedure below To configure in the standalo...

Страница 13: ...1 on Series 3 on the 5DX to the first ADP 232 J4 connector Figure 15 Model 5DX Stand alone BCR Configuration 2 Power on the BCR ADP 232 The Scan Head should generate a continuous series of raster sca...

Страница 14: ...t come on try these fixes Try scanning alternative barcode labels The first barcode sample may have been bad If still fails repeat Step 1 to ensure that all cable connections are good If still failing...

Страница 15: ...d window From the 5DX User Interface window select System Sytem Access Quit 5DX The multidrop configuration file should be modified for the Microscan 600 series scanner and the Series 5000 concentrato...

Страница 16: ...If no error message is generated then proceed to the next step If an error mes sage is displayed re check the scnr cfg file for the correct setup ADVICE Again the current scanner configuration will b...

Страница 17: ...r pin 7 to pin 11 on the concentrator A series of beeps should be heard Disconnect one end of the jumper and then quickly reconnect the jumper a single long higher pitched beep should be heard This lo...

Страница 18: ...rd barcode label Power on the ADP 232 and MS 5000 concentrator units if not already powered on From the Dos command prompt type alignbcr a The bar code reader will automatically start reading the bar...

Страница 19: ...anners used There is a second way to run ALIGNBCR EXE The user can specify an m parameter to operate the executable in manual mode In this mode a read cycle can only be generated by pressing the SPACE...

Страница 20: ...Automatic Barcode Reader 20 Figure 24 ALIGNBCR Usage and Output for Manual Mode 14 Configuration of the Bar Code Reader for the Agilent 5DX From the Agilent 5DX User Interface select System System Ac...

Страница 21: ...igure 25 Screen shot of results of Step 14 15 Use the arrow key and select Use serial number to find panel name Use arrow keys and select In Line Bar Code Reader Figure 26 Screen shot of results of St...

Страница 22: ...se is YES The number of bar code reader heads installed should be set to 2 or however many you are installing The read order of BCR heads should be set correctly Save changes Figure 28 Screen shot of...

Страница 23: ...mbers for loading CAD The customer must configure the Serial Number option to match the bar code label numbers for the correct applications to be inspected Refer to the Agilent 5DX Online Reference Gu...

Отзывы: