7
403
SCPI Command Reference
Commands with Variable Parameters and/or Setting Ranges Depending on
Device Configurataion
7. SCPI Command
Re
fe
re
nc
e
Commands with Variable Parameters and/or Setting Ranges
Depending on Device Configurataion
The table below lists the commands that have variable parameters and/or setting ranges
depending on the device configuration.
Table 7-1 SCPI Commands with Variable Parameters and/or Setting Ranges
Depending on Device Configuration
Command
Description
Sets/Reads the input attenuator level
Sets/Reads the signal supplied to the RF input port
:SENSe:DCONverter:MANual:IFDelta
Sets/Reads the differential frequency between CH1
and CH2 from the external mixer
:SENSe:DCONverter:MANual:IFGain[1-2]
Sets/Reads the IF gain of the external mixer
:SENSe:DCONverter:MANual:LO[1-2]:FREQuency
Sets/Reads the LO frequency of the external mixer
:SENSe:DCONverter:MANual:LO[1-2]:LEVel
Sets/Reads the LO level of the external mixer
:SENSe:DCONverter:MANual:MEXTernal[1-2]:BIAS:CURRent
Sets/Reads the bias current to be supplied to the
external mixer
:SENSe:DCONverter:MANual:MEXTernal[1-2]:BIAS:STATe
Sets the bias current supplied to the external mixer on
or off and reads its settings
Sets the use of the external mixer on or off and reads
its settings
:SENSe:FP[1-1]:DCONverter:FREQuency
Sets/Reads the input frequecny to be supplied to the
downconverter
:SENSe:FP[1-1]:DCONverter:SSEarch:EXECute
Searches carrier signal and reflects the result to the
input frequency of the downconverter (No Query)
Sets/Reads frequency band
:SENSe:FP[1-1]:POWer:INPut:LEVel:MAXimum
Sets/Reads the maximum input level of the
downconverter in order to determine the IF Gain
:SENSe:PN[1-1]:DCONverter:FREQuency
Sets/Reads input frequency of the downconverter
:SENSe:PN[1-1]:DCONverter:SSEarch:EXECute
Searches carrier signal and reflects the result to the
input frequency of the downconverter (No Query)
Sets/Reads frequency band
Sets/Reads the carrier frequency band
:SENSe:SP[1-1]:FREQuency:CENTer
Sets/Reads the center value
:SENSe:SP[1-1]:FREQuency:STARt
Sets/Reads the start value
Sets/Reads the stop value
:SENSe:TR[1-1]:NARRow:FREQuency:PREFerence
Sets/Reads the phase reference frequency of the
narrowband modeǵ
:SENSe:TR[1-1]:NARRow:FREQuency:TARGet
Sets/Reads the target frequency of the narrowband
mode
Содержание E5052A
Страница 4: ...4 ...
Страница 28: ...28 1 Making Effective Use of This Manual How to Use This Manual ...
Страница 51: ...3 51 Making a Measurement Trigger System 3 Making a Measurement Figure 3 1 Trigger system ...
Страница 58: ...58 3 Making a Measurement Waiting for End of measurement ...
Страница 76: ...76 4 Reading Writing Measurement Data Entering Data in a Trace ...
Страница 82: ...82 Chapter5 Saving and Recalling File Management Managing Files ...
Страница 476: ...476 AppendixB Status Reporting System Status Register Structure Figure B 3 Status register structure 1 of 6 ...
Страница 478: ...478 AppendixB Status Reporting System Status Register Structure Figure B 5 Status register structure 3 of 6 ...
Страница 480: ...480 AppendixB Status Reporting System Status Register Structure Figure B 7 Status register structure 5 of 6 ...