160
Agilent E1439 Programmer's Reference
Functions listed alphabetically
Parameters
id
is the VXI instrument session pointer returned by the
age1439_init
function.
data
is a pointer to the array into which the floating point data is to be placed. Be sure to allocate
sufficient storage space at this location to hold the full data record as determined by the
sampleCount
parameter. Note that when the module is set to complex data type, the output data
record contains 2 ×
sampleCount
floating point values. For real data the record contains
sampleCount
floating point values.
sampleCount
for
age1439_read
sampleCount
is the number of real or complex data values to read. Real data is
one 32-bit floating point value. Complex data is made up of two 32-bit floating point values
comprising the real and imaginary values.
for
age1439_read64
sampleCount
is the number of real or complex data values to read. Real data
is one 64-bit floating point value. Complex data is made up of two 64-bit floating point values
comprising the real and imaginary values.
This should never be set larger than the blocksize parameter set in the
age1439_data_blocksize
function. In continuous data collection mode,
sampleCount
should be set equal to blocksize to
ensure that the entire data block is read out.
overloadPtr
returns an overload indicator. The way to properly use the overload argument for the
age1439_
read
or
age1439_read64
function is this:
1. Set up the hardware.
2. Call
age1439_meas_start
.
3. Call
age1439_read
or
age1439_read64
.
If data is not available, the read function returns immediately with one of the following return values, and
the overload indication is
AGE1439_OFF
:
AGE1439_NO_DATA_MEASUREMENT_IN_PROGRESS
AGE1439_NO_DATA_MEASUREMENT_PAUSED
AGE1439_NO_DATA_WAITING_FOR_TRIGGER
AGE1439_NO_DATA_WAITING_FOR_ARM
When data is available, AGE1439_SUCCESS is returned and the overload value reflects whether an
overload was encountered for the given data block.
4. In continuous mode, subsequent data blocks can be read by calling a
age1439_
read
or
age1439_read64
function again (
age1439_meas_start
should not be called
again).
5. When used in this way, an overload indication is given for each and every
data block read in block mode. In continuous mode the overload indicator
only means there was an overload sometime after calling
age1439_meas_start
.
Comments on Overload
Since reading the status register clears the overload bit, overloads are tracked at the API level.
In block mode, you receive the overload indication on a block-by block basis by calling
age1439_
meas_start
and
age1439_read
in sequence.
In continuous mode, depending on the effective sample rate of the instrument and how often data
is read, an overload indication returned by
age1439_read
may or may not correspond to the data
returned. The overload indication only means that an overload has occurred since the most recent
Содержание E1439
Страница 6: ...6...
Страница 10: ...10 Contents...
Страница 11: ...1 1 Installing the Agilent E1439...
Страница 18: ...8 Installing the Agilent E1439 To transport the module...
Страница 19: ...2 2 Getting Started with the Agilent E1439...
Страница 28: ...18 Getting Started with the Agilent E1439 To use the example programs...
Страница 29: ...3 3 Using the Agilent E1439...
Страница 63: ...4 4 Agilent E1439 Programmer s Reference...
Страница 217: ...5 5 Module Description...
Страница 228: ...218 Module Description Block diagram and description...
Страница 229: ...6 6 Replacing Assemblies...
Страница 234: ...224 Replacing Assemblies Replaceable parts To remove the top cover...
Страница 235: ...225 Replacing Assemblies Replaceable parts To remove the M1 M2 assemblies...
Страница 236: ...226 Replacing Assemblies Replaceable parts...
Страница 238: ...228...
Страница 244: ...Index 234...