:TRIGger:TV:MODE
(see
Command Syntax
:TRIGger:TV:MODE <mode>
<mode> ::= {FIEld1 | FIEld2 | AFIelds | ALINes | LINE | VERTical
| LFIeld1 | LFIeld2 | LALTernate | LVERtical}
The :TRIGger:TV:MODE command selects the TV trigger mode and field.
The LVERtical parameter is only available when :TRIGger:TV:STANdard is
GENeric. The LALTernate parameter is not available when
:TRIGger:TV:STANdard is GENeric.
Old forms for <mode> are accepted:
Query Syntax
:TRIGger:TV:MODE?
The :TRIGger:TV:MODE? query returns the TV trigger mode.
Return Format
<value><NL>
<value> ::= {FIE1 | FIE2 | AFI | ALIN | LINE | VERT | LFI1 | LFI2
| LALT | LVER}
See Also
•
"Introduction to :TRIGger Commands"
•
•
<mode>
Old Forms Accepted
FIEld1
F1
FIEld2
F2
AFIelds
ALLFields, ALLFLDS
ALINes
ALLLines
LFIeld1
LINEF1, LINEFIELD1
LFIeld2
LINEF2, LINEFIELD2
LALTernate
LINEAlt
LVERtical
LINEVert
Содержание DSO6014A/L
Страница 1: ...A Agilent 6000 Series Oscilloscopes Programmer s Reference...
Страница 16: ...16 Agilent 6000 Series Oscilloscopes Programmer s Reference...
Страница 30: ...30 Agilent 6000 Series Oscilloscopes Programmer s Reference 1 What s New...
Страница 540: ...540 Agilent 6000 Series Oscilloscopes Programmer s Reference 6 Error Messages...
Страница 562: ...562 Agilent 6000 Series Oscilloscopes Programmer s Reference 7 Status Reporting...
Страница 584: ...584 Agilent 6000 Series Oscilloscopes Programmer s Reference 8 More About Oscilloscope Commands...
Страница 624: ...624 Agilent 6000 Series Oscilloscopes Programmer s Reference 9 Programming Examples...