![Agilent Technologies 83433A Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/agilent-technologies/83433a/83433a_user-manual_2868732026.webp)
2-7
Using the Agilent 83433A
Performing a Quick Confidence Check
5
Connect the data output of the pattern generator to the
DATA INPUT
of the
83433A.
6
Use the ruggedized optical cable with Panda polarization maintaining fiber to
connect the 83433A
CLASS IIIB INTERNAL LASER OUTPUT
to the
EXTENAL LASER
INPUT
.
7
Connect the 83433A
CLASS I OPTICAL OUT
to the input of an optical multimeter.
8
Set the pattern generator as follows:
Clock output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9953.28 MHz
Data output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External AC coupled
Data amplitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 V
Pattern. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
31
–1 PRBS
9
On the 83433A, ensure the wavelength adjust feature is disabled (front-panel
LED is off).
10
Turn the
LASER ENABLE
key to the ON position.
11
Measure the optical power at the output of the 83433A. It will show a minimum
of zero dBm.
Содержание 83433A
Страница 2: ...Agilent 83433A Lightwave Transmitter User s Guide...
Страница 9: ......
Страница 23: ...2 4 Using the Agilent 83433A Rear Panel Features Rear Panel Features...
Страница 31: ......
Страница 58: ...4 7 Specifications and Regulatory Information Regulatory Information Declaration of Conformity...
Страница 59: ......