Additional Safety Notices

The following general safety precautions 
must be observed during all phases of oper-
ation of this instrument. Failure to comply 
with these precautions or with specific 
warnings or instructions elsewhere in this 
manual violates safety standards of design, 
manufacture, and intended use of the 
instrument. Agilent Technologies assumes 
no liability of the customer’s failure to com-
ply with the requirements.

General

Do not use this products in any manner not 
specified by the manufacturer. The protec-
tive features of this product may be 
impaired if it is used in a manner not speci-
fied in the operation instructions. 

Before Applying Power

Verify that all safety precautions are taken. 
Make all connections to the unit before 
applying power.

Ground the Instrument

This product is provided with protective 
earth terminals. To minimize shock hazard, 
the instrument must be connected to the 
ac power mains through a grounded power 
cable, with the ground wire firmly con-
nected to an electrical ground (safety 
ground) at the power outlet. Any interrup-
tion of the protective (grounding) conduc-
tor or disconnection of the protective earth 
terminal will cause a potential shock haz-
ard that could result in personal injury. 

Do Not Operate in an Explosive 
Atmosphere

Do not operate the instrument in the pres-
ence of flammable gases or fumes.

Do Not Remove the Instrument 
Cover

Only qualified, service-trained personal 
who are aware of the hazards involved 
should remove instrument covers. Always 
disconnect the power cable and any exter-
nal circuits before removing the instrument 
cover. 

Do Not Modify the Instrument

Do not install substitute parts or perform 
any unauthorized modification to the prod-
uct. Return the product to an Agilent Sales 
and Service Office for service and repair to 
ensure that safety features are maintained. 

In Case of Damage

Instruments that appear damaged or defec-
tive should be made inoperative and 
secured against unintended operation until 
they can be repaired by qualified service 
personnel. 

Safety Symbols

Waste Electrical and Electronic 
Equipment (WEEE) Directive 
2002/96/EC

This product complies with the WEEE 
Directive (2002/96/EC) marking require-
ment. The affixed product label (see above) 
indicates that you 

must not discard this 

electrical/electronic product in domestic 
household waste

.

Product Category: With reference to the 
equipment types in the WEEE directive 
Annex 1, this product is classified as a 
“Monitoring and Control instrumentation” 
product. 

To return unwanted products, contact 

your local Agilent office, or go to 

www.agilent.com/environment/product

 

for more information.

Technical Support

If you have questions about your shipment, 
or if you need information about warranty, 
service, or technical support, contact 

Agilent Technologies:

In the United States: (800) 829-4444

In Europe: 31 20 547 2111

In Japan: 0120-421-345

Or go to 

www.agilent.com/find/assist

 

for information on contacting Agilent in 
your country of specific location. You can 
also contact your Agilent Technologies 

Representative. 

Alternating current

Frame or chassis 
terminal

Standby supply. Unit is 
not completely 
disconnected from ac 
mains when switch is off 

Caution, risk of electric 
shock

Caution, refer to 
accompanying description

Agilent 34952A Multifunction Module 

User’s 

Guide

       iii

Содержание 34952a

Страница 1: ...and service on the web www keysight com Select your country from the drop down menu at the top Under Electronic Test and Measurement click on Services The web page that appears next has contact infor...

Страница 2: ......

Страница 3: ...Agilent Technologies Agilent 34952A Multifunction Module User s Guide Agilent Technologies Inc Printed in Malaysia Edition 2 September 2012 E0912 34980 90052 34980 90052...

Страница 4: ......

Страница 5: ...any information contained herein Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms the warranty te...

Страница 6: ...circuits before removing the instrument cover Do Not Modify the Instrument Do not install substitute parts or perform any unauthorized modification to the prod uct Return the product to an Agilent Sal...

Страница 7: ...net There are two methods to obtain the Declaration of Conformity Go to http regulations corporate agilent com DoC search htm You can then search by product number to find the latest Declaration of Co...

Страница 8: ...s 34952A Multifunction Module 1 Digital Input Output 1 Totalizer Input 1 Analog Output DAC 1 34952A SCPI Programming Examples 2 Digital Input Output 2 Totalizer 2 DAC Output 3 34952A Simplified Block...

Страница 9: ...vi Agilent 34952A Multifunction Module User s Guide...

Страница 10: ...nternal 5 V pull up resistors when configured as inputs Totalizer Input The 32 bit totalizer can count pulses at a 100 kHz rate You can configure the totalizer to count on the rising edge or falling e...

Страница 11: ...s an output and then reads the output value the channel is not reconfigured as an input Then the channel is reconfigured as an input and the value is read again The second command below returns 64 as...

Страница 12: ...on the specified totalizer channels The following command clears the count on the totalizer channel 5 on a Multifunction module in slot 3 TOTalize CLEAR IMMediate 3005 DAC Output Example Setting outp...

Страница 13: ...Diagram DIO 32 Bits Totalizer Count Count Channel 005 Gate D A1 Channel 006 16 Bits D A2 16 Bits Channel 007 8 8 8 8 Channel 001 Bit 0 Bit 7 Channel 002 Bit 8 Bit 15 Channel 003 Bit 16 Bit 23 Channel...

Страница 14: ...0 DAC 1L DAC 2H DAC 1H NC GND GND GND DAC 2L 50 50 Pin D Sub Female Connector Description Socket Description Socket Description Socket Description Socket Channel 1 Bit 0 4 Channel 3 Bit 16 26 Channel...

Страница 15: ...r The 34980A Product Reference CD shipped with the instrument contains a 34952T Wiring Log for you to document your wiring configuration for this module You can open the wiring log file in Microsoft E...

Страница 16: ...Guide 7 Index A analog output 1 C connector pinouts 5 D DAC output 1 digital I O 1 D sub pinouts 5 M module description 1 P pinouts 5 programming examples 2 S simplified block diagram 4 T terminal blo...

Страница 17: ...8 Agilent 34952A Multifunction Module User s Guide Index...

Отзывы: