background image

47

Agilent 16800 Series Portable Logic Analyzers
Installation/Quick Start Guide

 

Agilent Technologies

5
Safety Notices

Warnings

48

To clean the instrument

49

Safety Symbols

50

This apparatus has been designed and tested in accordance with IEC 
Publication 1010, Safety Requirements for Measuring Apparatus, and has been 
supplied in a safe condition. This is a Safety Class I instrument (provided with 
terminal for protective earthing). Before applying power, verify that the 
correct safety precautions are taken (see the following warnings). In addition, 
note the external markings on the instrument that are described under "Safety 
Symbols."

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание 16800 Series

Страница 1: ...underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In...

Страница 2: ...Agilent Technologies Agilent 16800 Series Portable Logic Analyzers Installation Quick Start Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 3: ...y terms in the sep arate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accor dance...

Страница 4: ...and 48 pattern generator channels depending on the model Pod Cables Accessories Pouch top flap Tie down Straps Run Stop Keys USB 2 0 Ports 2 Scroll Knob Table 1 Model comparisons Agilent model number...

Страница 5: ...isk drive or external hard drive 16800A Option 109 10 100 Base T LAN port USB 2 0 ports six total two on front four on back One PCI expansion slot One PCI Express x1 expansion slot Windows XP Professi...

Страница 6: ...alyzer Use it to store probe leads accessories or manuals Use the tie down straps under the flap to conveniently hold pod cables not in use or during transport Optional Accessories Probes Front Panel...

Страница 7: ...This chapter describes some basic features of the logic analyzer and tells you where to find more information on using the logic analyzer 3 Updating the Logic Analyzer This chapter describes how to ch...

Страница 8: ...ot appear 16 Additional First Time Setup Steps 17 Establishing an Administrator Account recommended for standalone and networked instruments 17 Protecting the Instrument s Operating System 17 2 Gettin...

Страница 9: ...tore the logic analyzer firewall defaults 37 Software Installation and Upgrades 40 Agilent Logic Analyzer Software 40 Optional Products 40 4 Solving Problems 41 Running Self Tests 42 If the logic anal...

Страница 10: ...Contents 16800 Series Portable Logic Analyzers Installation Quick Start Guide 9 Index 51 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 11: ...10 16800 Series Portable Logic Analyzers Installation Quick Start Guide Contents Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 12: ...rt Guide Agilent Technologies 1 First Time Set Up Proper Cooling 12 First Time Set Up Considerations 13 Answering Windows Welcome Questions 15 Additional First Time Setup Steps 17 Artisan Technology G...

Страница 13: ...nalyzers Installation Quick Start Guide Proper Cooling Allow at least 5 cm 2 inches of space between instruments for proper cooling 5 cm 2 inches 5 cm 2 inches Artisan Technology Group Quality Instrum...

Страница 14: ...analyzer sharing files is done via USB flash drive or floppy disk Connected to a Network If you require the ability to print share files remotely control the logic analyzer etc over the network you n...

Страница 15: ...work print transfer files etc your instrument must be configured appropriately for the networking model in use at your site Information you may require to complete your network configuration may inclu...

Страница 16: ...ollows the suggestions on the screen less than 15 characters etc What s your administrator password Agilent recommends entering an administrator password for administrator accounts See page 17 for act...

Страница 17: ...through a network N A Choose Yes through a network Agilent does not support connecting to the internet through a modem directly connected to the logic analyzer N A If LAN is not connected Windows unab...

Страница 18: ...in to the Administrator account to do the following Install most software applies whether the instrument is networked or standalone Change the workgroup Perform Windows Updates Change firewall setting...

Страница 19: ...1 First Time Set Up 18 16800 Series Portable Logic Analyzers Installation Quick Start Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 20: ...ogic Analyzer Probing 20 Making a Measurement 21 Snap to Edge Markers 23 Left Click Menus 24 Tree Structure Bus Signal Names 24 Offline Analysis 25 Marker Overview 25 Tool Tips 26 Trigger History 27 S...

Страница 21: ...system under test For more information on Agilent probes See the quick reference card that came with your logic analyzer for an overview of probing solutions Go to www agilent com find logic_analyzer_...

Страница 22: ...rs Installation Quick Start Guide 21 Making a Measurement 1 Start up the logic analyzer connect to your target system and select Setup Bus Signal 2 Assign buses and signals and click OK Artisan Techno...

Страница 23: ...Logic Analyzer 22 16800 Series Portable Logic Analyzers Installation Quick Start Guide 3 Enter a trigger value 4 Acquire and view data Artisan Technology Group Quality Instrumentation Guaranteed 888 8...

Страница 24: ...rs Installation Quick Start Guide 23 Snap to Edge Markers You can set the markers to jump to the nearest edge of a waveform A yellow target will show which edge the marker will jump to Artisan Technol...

Страница 25: ...Start Guide Left Click Menus Drag a box around parts of the data When you release the mouse button a menu appears Tree Structure Bus Signal Names Show individual signals in buses by clicking on the t...

Страница 26: ...n and Upgrades on page 40 to load the 16800 Series logic analyzer software on your PC 2 Acquire a trace with the logic analyzer 3 Save a configuration file with data 4 Copy the file to the PC being us...

Страница 27: ...26 16800 Series Portable Logic Analyzers Installation Quick Start Guide Tool Tips Pause the cursor over a tool Icon and a Tool Tip Window will appear Artisan Technology Group Quality Instrumentation G...

Страница 28: ...gic Analyzer 2 16800 Series Portable Logic Analyzers Installation Quick Start Guide 27 Trigger History Save and recall trigger settings Artisan Technology Group Quality Instrumentation Guaranteed 888...

Страница 29: ...tton on the logic analyzer for a short time less than 2 seconds Closes all programs that are running Writes all data to the disk Turns off the power supply If the power button on the Remote Desktop is...

Страница 30: ...the system will not power on until the power button is pressed Unplugging the Power Cord or Power Loss Unplugging power or a power loss is similar to the long press of the power button with one excep...

Страница 31: ...803A 115 230 Vac 20 48 66Hz 615W Max 16804A 16806A 16821A 16822A and 16823A 115 230 Vac 20 48 66Hz 775W Max CAT II Line voltage in appliance and to wall outlet Pollution degree 2 Environmental Charact...

Страница 32: ...31 More specifications and characteristics for your instrument and measurement modules are in the on line help To find them go to 1 Click Help Help Topics 2 Click Reference then click Specifications a...

Страница 33: ...etting Started with the Logic Analyzer 32 16800 Series Portable Logic Analyzers Installation Quick Start Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg c...

Страница 34: ...ick Start Guide Agilent Technologies 3 Updating the Logic Analyzer Changing Network Settings 34 Changing Windows Firewall Settings 35 Software Installation and Upgrades 40 Artisan Technology Group Qua...

Страница 35: ...hen right click on My Computer and select Properties Select the Computer Name tab and click Change To change network connection properties click Start Control Panel Network Connections Select the conn...

Страница 36: ...To give other applications ports access through the firewall For example you may need to change firewall settings in order to Use NetOp to remotely control the logic analyzer Use RealVNC to remotely c...

Страница 37: ...Add Port to give unlisted ports access through the firewall Refer to the application s documentation for information on port numbers or other firewall setup information NOTE Note that there are separ...

Страница 38: ...ation Quick Start Guide 37 To restore the logic analyzer firewall defaults 1 From the Windows Start menu choose Start Control Panel 2 In the Control Panel window open Windows Firewall Artisan Technolo...

Страница 39: ...Firewall dialog 7 From the Windows Start menu choose Start Run then enter or select the file C Program Files Agilent Technologies Logic Analyzer agFirewSP2 wsf and click OK The logic analyzer firewall...

Страница 40: ...quest Allow outgoing destination unreachable Allow outgoing time exceeded NOTE Note that there are separate Windows Firewall profiles Domain for when the computer has domain membership and Standard fo...

Страница 41: ...sion as a step in the upgrade User files in the Documents and Settings tree are not affected To install the logic analyzer software onto your PC for offline processing insert the product CD into your...

Страница 42: ...powers itself down 43 If the Power LEDs do not come on 43 If you get a registry error and the system won t boot 43 If there are network connection problems 44 If there are touch screen problems 45 Usi...

Страница 43: ...ick Start Guide Running Self Tests 1 In the Agilent logic analyzer application click Help Self Test 2 In the analysis system Self Test dialog double click on the test you want to run Artisan Technolog...

Страница 44: ...registry error and the system won t boot When powered off unexpectedly for example with a long press of the power button or a power loss Windows XP may not flush all system information to disk and is...

Страница 45: ...ts Allow outgoing destination unreachable Allow outgoing time exceeded See To restore the logic analysis system firewall defaults on page 89 The link activity light must be on If these LEDs are not on...

Страница 46: ...ns is off You may be able to calibrate the touch screen to fix the problem 1 From the Windows Start menu choose Start All Programs Agilent Logic Analyzer Utilities Touch Screen Settings 2 In the UPDD...

Страница 47: ...want any data left on it You need to have a keyboard mouse and USB DVD ROM drive connected Follow the instructions provided with the recovery DVD to restore your system software Contacting Agilent Ser...

Страница 48: ...Safety Requirements for Measuring Apparatus and has been supplied in a safe condition This is a Safety Class I instrument provided with terminal for protective earthing Before applying power verify th...

Страница 49: ...ust make the instrument inoperative and secure it against any unintended operation Service instructions are for trained service personnel To avoid dangerous electric shock do not perform any service u...

Страница 50: ...eaning 1 Remove power from the instrument 2 Clean the external surfaces of the instrument with a soft cloth dampened with a mixture of mild detergent and water 3 Make sure that the instrument is compl...

Страница 51: ...s marked with this symbol when it is necessary for you to refer to the instruction manual in order to protect against damage to the product Hazardous voltage symbol Earth terminal symbol Used to indic...

Страница 52: ...oftware 40 internet 15 inverse assemblers 40 L LAN 15 LEDs 43 N network adding logic analyzer 14 connection decision 13 debugging 44 network connection problems 44 network settings 34 O optional tools...

Страница 53: ...n Quick Start Guide Index W windows power problems 43 updates 17 welcome 13 welcome questions 15 Windows Firewall settings changing 35 workgroup 13 changing 17 Artisan Technology Group Quality Instrum...

Страница 54: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: