Post-Processing and Analysis Tool Sets
Serial Analysis
Product Characteristics
Data Sources
All state and timing measurement
modules supported by the 16700
Series logic analysis systems serve
without modification as data sources
for the B4601B serial analysis tool
set. The particular measurement
module used determines time resolu-
tion and accuracy. Sample rate, chan-
nel count, memory depth and trigger-
ing are controlled by the user inde-
pendent of the serial analysis tool.
Because every trace is non-intrusive,
and every event captured in the trace
is time-stamped, you can correlate
activity from your serial bus with
other events in the target system.
The Agilent Technologies 16720A and
16522A pattern generator modules
can be used to generate your own
serial test data.
Maximum Parallel Word Width
32 bits
Parallel Data Display Types
Binary, Octal, Hex, Decimal, ASCII,
Twos Complement
Off-line Analysis and Post-Processing
All measurements can be saved using
the file out tool. Data can be recalled
at any time for later analysis using
any analysis or display tool. Serial
measurement data can be exported to
your host computer as ASCII files.
Serial Measurement Characteristics
16517A/18A
16710A/11A/12A
16715A
16716A
16717A/18A/19A
16750A/51A/52A
Maximum serial
Clocked data [1]
64 Kbits
8 Kbits/32 Kbits/
2 Mbits
512 Mbits
2 Mbits/8 Mbits/
4 Mbits/16
Mbits/
trace depth
128 Kbits
32 Mbits
32 Mbits
Unclocked data [2]
16-32 Kbits
4 Kbits/16Kbits/
1 Mbit
256 Mbit
1 Mbit/4 Mbits/
2 Mbits/8 Mbits/
64 Kbits
16 Mbits
16 Mbits
Maximum serial
Clocked data [3]
1 Gbit/s
100 Mbits/s
167 Mbits/s
167 Mbits/s
333 Mbits/s
400 Mbits/s
bus frequency
Unclocked data [4]
1 Gbit/s
125 Mbits/s
167 Mbits/s
167 Mbits/s
167 Mbits/s
200 Mbits/s
Minimum serial
Clocked data
20 Mbit/s
No limit
No limit
No limit
No limit
No limit
bus frequency
Unclocked data [5]
765 Mbits/s
5 Kbits/s
50 bits/s
50 bits/s
50 bits/s
50 bits/s
Information in Table above calculated according to notes [1] to [5]
[1] =Maximum State Memory Depth
[2] =Maximum Timing Memory Depth/4
[3] =Maximum State Frequency
[4] =Maximum Timing Frequency/4
[5] =1/(Maximum sample period x 20)