The followings settings are active in the as-
delivered state:
- The switches S130 /S01 (termination for

the external S0 access) are closed and the
100 Ohm terminators are on.

- Switchable S0 access: set to external. The

switches S130 /S02 (termination for the
external S0 access) are closed and the 100
Ohm terminators are on.

- Internal phone numbers / terminal type:

11, 12, 13, telephone

- Outside line access: unlimited for all users
- Outside line seizure: "0"
- Call variant 1 (day time): no entry
- Call variant 2 (night time): no entry
- Internal call forwarding: off
- Do not disturb: off for all terminals
- Call waiting announcement prevention: off

for all terminals

- Phone number communication to the

called party and the caller: on

- Music on hold (MoH): internal on

- Automatic dialling: off
- Connection record printing: off for all

users

- Dialled phone number printing: none
- Cost limit: no entry
- Own tariff units factor: 0006
- Basic factor: 0.06
- Cleardown at cost limit: off
- Set up code: off
- Switching box code: no entry
- Busy tone on busy: off
- Communication of "0" for dialling from the

call list on the internal S0 access: off

System telephones ST 20 and ST 25

- Status display: off

- Cost display: off
- Display: English
- Call list: off

By programming on a PC, you can set the
telephone system’s functions to suit your
needs. Remote setting by your specialist
dealer is possible.

Commissioning

You have installed the telephone system.
Now, only a few operations are necessary
before you are able to make telephone
calls.

- Connect terminals. You can connect all

terminals that you are also allowed to
connect to the public
telecommunications network.

- Insert the Western plug on the ISDN

connecting cable in the
telecommunications socket (ISDN line
unit, IAE or universal line unit UAE) of
your ISDN connection.

- To avoid wrong dialling, dial a digit on an

a/b terminal with DTMF after installation.
The telephone system recognises the di-
alling method in this way.

- If you switch the dialling method on an a/b

terminal from DTMF to pulse dialling, dial
a digit higher than 2.

- If you operate two terminals on one ter-

minal connection, both of them must dial
with the same dialling method.

Notes ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

- Switch on the telephone system by in-

serting the mains plug.

- Once the telephone system has been

switched on, you can immediately make
internal and external telephone calls.
When an external subscriber calls, all
connected telephones ring according to
the telephone system's default settings
("as-delivered" settings).

- By programming on a PC, you can set

the telephone system’s functions to suit
your needs. Remote setting by your
specialist dealer is possible.

As-delivered state ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

Содержание AS 40P

Страница 1: ...Installation manual Profi Line AS 40 AS 40 P ISDN PABX System...

Страница 2: ...ring a thunderstorm Lay subscriber lines in such a way that no one can step on them or stumble over them Prevent the ingress of liquid into the telephone system as otherwise short circuits may occur N...

Страница 3: ...here are no explosion hazards It must not be installed in the proximity of air conditioning systems radiators devices that produce inadmissible inter ference radiation in locations that are subject to...

Страница 4: ...s and pull down the telephone sys tem on the wall until it moves no further Firmly screw down the telephone system with the third screw in the bottom dowel Figure 1 telephone system with detached cove...

Страница 5: ...latching lug of the module latches into the lock Pull the adhesive label showing the module s connections off the information sheet included with the Installing and replacing modules module packaging...

Страница 6: ...ystem Fixed slot X 0 outside right The con nection module must not be plugged on to any other slot as otherwise the connector will be damaged Interfaces 1 External S0 interface S0 0 1 ISDN basic acces...

Страница 7: ...one ISDN telephone system to an ISDN point to point connec tion You cannot connect any further ISDN terminals Using the ISDN connecting cable connect the ISDN telephone system directly to the NTBA or...

Страница 8: ...telephone system is not the last ISDN device on a PTMP line Plug the ISDN Plug into the ISDN connection after completion of all installation work Both switches S1301 cd are on the compo nent side of t...

Страница 9: ...nternal S0 connection 100 Wire pair 1 a1 b1 Wire pair 2 a2 b2 b1 b2 a1 a2 S0 internal 100 Max distance 130 m S0 bus 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 b1 b...

Страница 10: ...ario ports You must not connect the Da and Db wires System telephone Connect system telephones by means of four wires to the Vario ports by connecting them to the La and Lb wires speech wires and the...

Страница 11: ...cting subscriber lines Mark the cables with the included mark ing system Strip 11 mm off the wires Push the individual wires into the termi nal until they move no further without pressing the terminal...

Страница 12: ...e S0 Module 420 The S0 module features the following in terfaces 1 External S0 interface S0 X 1 ISDN basic access as a point to multipoint or point to point connection 1 Switchable internal external S...

Страница 13: ...SDN sockets IAE UAE may belong to this S0 bus Be sides the ISDN telephone system you can connect up to 7 further ISDN terminals to the S0 bus Terminators for the external S0 access S0 0 1 For the poin...

Страница 14: ...ephone system is not the last ISDN device on a PTMP line Plug the ISDN Plug into the ISDN connection after completion of all installation work Both switches S4102 ab are on the compo nent side of the...

Страница 15: ...nternal S0 connection 100 Wire pair 1 a1 b1 Wire pair 2 a2 b2 b1 b2 a1 a2 S0 internal 100 Max distance 130 m S0 bus 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 b1 b...

Страница 16: ...nternal external S0 interfaces external ISDN basic access as a point to multipoint or point to point connection internal point to multipoint connection Slots X 1 to 4 freely optional Switching to an i...

Страница 17: ...stermann 230 V TO NF NF TS KT KT door opener bell transformer for door opener The TFE Module 402 door hands free unit The TFE module 402 features two interfaces conforming to the 4 wire TFE specificat...

Страница 18: ...ener The TFE Module 403 door hands free unit The TFE module 403 features an interface TFE 1 that conforms to the Telekom 2 wire TFE CE interface specification for connecting DoorLine T01 to T04 door h...

Страница 19: ...ushbuttons Connections Figure 12 Connect the DoorLine T01 to T04 door hands free units to the contacts NF and NF Controlling the door opener Maximum contact load 30 V DC 1 A You can only actuate the d...

Страница 20: ...u must plug the TFE modules in the following arrangement Slot from left to right TFE module 402 relay 1 to 4 TFE module 402 relay 5 to 8 TFE module 402 or 403 TFE TFE Module 403 Instead of the door ha...

Страница 21: ...r cassette recorder or stereo system with a 3 5 mm jack plug to the jack socket X external MoH on the underside of the telephone system Figure 1 Set the volume of external music on hold on the audio d...

Страница 22: ...onnection you need a cable that corresponds to the pin as signments given below maximum length 3 m Your printer must be set as follows 9600 baud 8 bits 1 stop bit no parity To print out connection rec...

Страница 23: ...as far as the stop Fig 16 Locking the cover Figure 15 Figure 16 Pull out the black bolt slightly to the side using a narrow srewdriver blade about 2 mm wide until you can grip the bolt Fig 17 and 18 h...

Страница 24: ...on a PC you can set the telephone system s functions to suit your needs Remote setting by your specialist dealer is possible Commissioning You have installed the telephone system Now only a few operat...

Страница 25: ...access 1 switchable internal external S0 access S0 module 440 4 switchable internal external S0 access TFE module 402 2 interfaces for the connection of 2 door hands free 4 wire units to FTZ 123 D 12...

Страница 26: ...32C Range level 3 m 5 V Connection 9 pole D sub socket External music on hold e g via a variable headphone output of a cassette recorder or CD player Input impedance 100 kOhm asymmetrical Input voltag...

Страница 27: ...This applies to electronic mechanical optical chemical and other media Trademarks and company names used in this documentation are subject to the rights of the respectively affected compa nies Technic...

Страница 28: ...GmbH Co KG Gaswerkstr 8 D 33647 Bielefeld Internet http www agfeo de Ident No 1529435 Subject to change without notice No liability can be accepted for errors contained in this document Printed in Ger...

Отзывы: