Diagnostic and Error Messages
4–21
66 Continuous Media Feed
Media rollers are continuing to move with or without
media feed.
Clear error code.
Reset. If the error persists, call for service.
67 Media Blocking Take-up Sensor
Media is detected in the cutter area.
Remove and process the take-up cassette containing
media. Check for media in the cutter area. Follow the
procedures given in the Troubleshooting Media Jams
chapter of this user guide.
Reset. If the error persists, call for service.
68 Jam in Buffer Before Buffer Entry
Sensor
The buffer entry sensor does not sense media.
Remove the bridge covers and clear any media.
Carefully reseat the bridge covers and close cover.
Reset. If the error persists, call for service.
69 Jam in Buffer Before Purchase
Sensor
Jam in Buffer area.
Remove the buffer top panel and cover and check for any
media within buffer area. Replace the top panel and
cover.
Reset. If the error persists, call for service.
Содержание SelectSet Avantra 20
Страница 1: ...ABC SelectSet Avantra Series Control Panel and Operating Guide Part Number M00123 0002...
Страница 3: ...ABC SelectSet Avantra Series Control Panel and Operating Guide Part Number M00123 0002...
Страница 12: ...Overview...
Страница 15: ...Chapter 1 Product Overview...
Страница 36: ...Chapter 2 Using the Imagesetter Control Panel...
Страница 95: ...Chapter 3 Running Exposure Tests...
Страница 110: ...Chapter 4 Diagnostic and Error Messages...
Страница 143: ...Chapter 5 Imagesetter Maintenance...
Страница 146: ...Imagesetter Maintenance 5 3 Figure 5 1 Supply rollers in the media compartment...
Страница 157: ...Appendix A RIP and Avantra User Tools...
Страница 167: ...Index...