![AGCO HayBoss G2 600A1 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/agco/hayboss-g2-600a1/hayboss-g2-600a1_installation-manual_2866425009.webp)
9
Wiring Installation
– 600UHD1
Connecting to the Baler Harness
Locate the communication harness
(006-6650VAU) and the connection point
shown (Left) on baler.
Under the chamber locate the Active Terminator from the
end of the baler harness. Labeled (LHR-C72 ISOBUS Term)
It is located at the right rear corner of the baler frame. Attach
Baler Interface Harness (006-6650VAU) to that location.
Reconnect Active Terminator to open port of that same
harness (006-6650VAU).
Attach power harness (006-6650AU) to gray plug labeled
(LHR-C73) in same location. Run wire up to the DCP and
attach to the port labeled power.