OPERATION
BEFORE USE:
Before using the DCS, whether for the first time
when new, or for the season:
1. Connect hydraulic hoses correctly and be sure
rocker switch on bottom of monitor is positioned
correctly (next column).
2. Connect electrical system (next column).
3. Purge air from implement hydraulic lift system
4. Calibrate DCS for implement (p. 5).
HYDRAULIC AND ELECTRICAL
CONNECTIONS
Hydraulic System Types
Note:
See tractor dealer if unsure what type
hydraulic system is in tractor.
If the tractor has:
-An open-center hydraulic system, the optional
solenoid valve must be installed with the switch
red end showing (next page).
- A closed-center system, the valve is not
required and the switch must be positioned to
NOT show red.
- A pressure-compensated system, the valve
may or may not be required and the switch must
be positioned accordingly.
Due to differences between tractor brands and
models with pressure-compensated hydraulic
systems, no one switch position can be specified for
all. In general, if the switch is set for a close-center
system but engine speed drops by five rpm or more
when the automatic mode is turned on, the optional
valve is required.
IMPORTANT!
Do not operate DCS with switch in
open-center mode (red showing) without valve
installed.
Hose Connections to Tractor
Connect the lift cylinder hoses to the tractor outlets
(Fig. 3) as follows:
- Hose from Port T-1 (side of valve block) to
pressure outlet.
- Hose from Port T-2 (front) to return outlet.
Note:
If connected otherwise, implement will not lift
or lower in either automatic or manual mode.
Electrical
The control monitor can be connected directly to the
battery or to an in-cab auxiliary plug. Harnesses for
both connections are included in the DCS kit.
When connecting directly to the battery, connect:
- Black wire (-) to negative terminal.
- Red wire (+) to positive terminal.
Note:
DCS will not work if wires are reversed.
3
Fig. 3 - Front of Valve Block
1. Solenoid Ports A, B, T1, T2
2. Optional Solenoid
T1
2
1
B
A
DCS-3A
Содержание Glencoe DCS3000
Страница 2: ......
Страница 4: ...NOTES ii...
Страница 27: ...INSTALLATION WIRING SCHEMATIC All Models 23 Fig 29 Schematic for DCS 3000...
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 36: ...Glencoe AGCO CORPORATION 4205 River Green Parkway Duluth Georgia 30096 Printed in U S A...