This device has been tested and found to be in compliance
with FCC Part 15, Subpart B. These limits are designed to
provide reasonable protection against harmful interference
when the equipment is operated in a commercial
environment. This product generates, uses, and can radiate
radio frequency energy, which may cause interference to
other equipment. If in doubt about possible interference to
other equipment, please contact your distributor for support.
Guidance and manufacturer’s declaration – electromagnetic emissions
The Model iBGSTAR is intended for use in the electromagnetic environment specified
below. The customer or the user of the Model iBGSTAR should assure that it is used in
such an environment.
Emissions test
Compliance
Electromagnetic environment – guidance
RF emissions
CISPR 11
Group 1
The Model iBGSTAR uses RF energy only
for its internal function. Therefore, its RF
emissions are very low and are not likely to
cause any interference in nearby electronic
equipment.
RF emissions
CISPR 11
Class B
The Model iBGSTAR is suitable for use in
all establishments, including domestic
establishments and those directly
connected to the public low-voltage power
supply network that supplies buildings used
for domestic purposes.
Harmonic emissions
IEC 61000-3-2
Class A
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Complies
E
le
c
tr
o
m
a
g
n
e
ti
c C
o
m
p
a
ti
b
il
it
y (
E
M
C
)
Guidance and manufacturer’s declaration – electromagnetic immunity
The Model iBGSTAR Image Intensifier is intended for use in the electromagnetic
environment specified below. The customer or the user of the Model iBGSTAR Image
Intensifier should assure that it is used in such an environment.
IMMUNITY
test
IEC 60601 test
level
Compliance
level
Electromagnetic
environment – guidance
Electrostatic
discharge
(ESD)
IEC 61000-4-2
± 6 kV contact
± 8 kV air
± 6 kV contact
± 8 kV air
Floors should be wood,
concrete or ceramic tile. If floors
are covered with synthetic
material, the relative humidity
should be at least 30 %.
Electrical fast
transient/
burst
IEC 61000-4-4
± 2 kV for power
supply lines
± 1 kV for input/
output lines
± 2 kV for power
supply lines
± 1 kV for input/
output lines
Mains power quality
should be that of a typical
commercial or hospital
environment.
Surge
IEC 61000-4-5
± 1 kV line(s) to
line(s)
± 2 kV line(s) to
earth
± 1 kV
differential mode
± 2 kV common
mode
Mains power quality
should be that of a typical
commercial or hospital
environment.
IEC 61000-4-11
Voltage
dips, short
interruptions
and voltage
variations on
power supply
input lines
<5 %
U
T
(>95 % dip in
U
T
)
for 0,5 cycle
40 %
U
T
(60 % dip in
U
T
)
for 5 cycles
70 %
U
T
(30 % dip in
U
T
)
for 25 cycles
<5 %
U
T
(>95 % dip in
U
T
)
for 5 s
5 %
U
T
(>95 % dip in
U
T
)
for 0,5 cycle
40 %
U
T
(60 % dip in
U
T
)
for 5 cycles
70 %
U
T
(30 % dip in
U
T
)
for 25 cycles
<5 %
U
T
(>95 % dip in
U
T
)
for 5 s
Mains power quality should
be that of a typical commercial
or hospital environment. If
the user of the Model iBGSTAR
image intensifier requires
continued operation during
power mains interruptions,
it is recommended that
the Model iBGSTAR Image
Intensifier be powered from an
uninterruptible power supply
or a battery.
Power
frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
3 A/m
3 A/m
If image distortion occurs, it
may be necessary to position
the Model iBGSTAR image
intensifier further from sources
of power frequency magnetic
fields or to install magnetic
shielding. The power frequency
magnetic field should be
measured in the intended
installation location to assure
that it is sufficiently low.
NOTE
U
T
is the a.c. mains voltage prior to application of the test level.