6
NOTE:-
A suitable chimney (minimum profile, chimney draft, tightness, etc) is a basic condition for the
proper functioning of fireplace stoves. See professional advice before installing the stove.
Chimney values are included in the attached technical sheet. A smoke shutter or a draft regulator
should be installed for chimneys with too strong a draft. Such a draft can cause problems during
operation, e.g. intensive burning, high fuel consumption and can also lead to permanent damage to
the stove.
STOVE DIMENSIONS
Fig. 4
Note: Dimensions stated are in milimeters and may be subject to a /- variation.
TECHNICAL DATA
FUEL
WOOD
ANCIT
Nominal Output - Room
4.8 kW
4.9 kW
Typical refuelling intervals to
obtain nominal outputs
1 Hour
1 Hour
Fuel Gas Mass Flow
4.4 g/s
3.7 g/s
Flue Gas Temp at Nominal Output
262
o
C
275
o
C
Gross Weight
105 kgs
Flue Outlet
125mm
Log Size
310mm
This appliance has been tested in accordance with BS EN 13240