WARNING: BEFORE REMOVING SERVICE ACCESS
COVERS OR THE BURNERS ENSURE THAT ALL
ELECTRICAL SUPPLIES TO THE APPLIANCE HAVE
BEEN ISOLATED.
SEE FIG. 3
1.
Open up the bottom door access door. Remove door
and put in a safe place.
2.
Remove the 4 inner panel securing screws and
remove panel.
3.
Remove the 3 plinth securing screws and remove
plinth.
1.
Ensure cooker gas cock is closed.
2.
Disconnect flexible gas inlet as shown, ensuring not to
lose o-ring. (See Fig. 4).
3.
All of the items in Fig. 5 need to be disconnected
before the burner assembly can be removed.
Cooker Burner Servicing
PREPARATION
6
BURNER ACCESS
FIG. 3
DESN 514878
FIG. 4
DESN 514879
PARTS TO BE REMOVED TO
WITHDRAW COOKER BURNER
DESN 514880
FIG. 5
FIG. 6