5. OPERATING INSTRUCTIONS
Switch on the power at the fused spur.
The extractor has 6 pushbuttons, which illuminated when
pressed. Their functions are described below:
6. MAINTENANCE
Regular maintenance is essential to ensure good
performance and long-life.
To maintain the immaculate appearance of the extractor,
and to minimise fire risk, ensure that grease deposits on
the extractor surfaces are kept to a minimum by regular
cleaning.
To clean the stainless steel surfaces of the extractor, use a
soft cloth and a suitable cleaning agent, such as a specially
produced stainless steel cleaner or washing up detergent
and warm water.
Painted surfaces should be cleaned using a soft cloth,
detergent and warm water.
Glass surfaces should be cleaned with a suitable glass
cleaning agent.
Do not use abrasive cleaning materials or products.
Do not use bleach based cleaning materials or
products.
Clean the grease filters in a dishwasher or by hand-
washing in hot water and detergent every 2 months -
sooner if the extractor is used extensively and filters
become grease laden.
Whilst you can expect years of service from mesh
grease filters, they are considered a consumable item
and may deteriorate over time and need replacement,
particularly when cleaned in a dishwasher. For
dishwasher users adhering to a 2 monthly cleaning
interval we recommend grease filter replacement every
5 years to maintain optimum performance, even if they
show no visible signs of deterioration. For all users,
filters should be replaced whenever they exhibit signs
of physical wear.
6.1. Removing the Grease Filters
The filters have an integrated sprung latch and release
mechanism.
Release the latch by pulling the lever and remove the filter.
The filter is replaced by locating the fixed tabs on the filter into
corresponding slots in the extractor base and then pushing the
filter into position with the latch held open. Once the filter is in
position carefully release the lever, allowing the latch to
engage.
6.2. Replacing Lamps
The LED lamps are not designed for end user replacement.
7. SPECIFICATIONS
FM900 Built-In Extraction Canopy
Airflow, nominal in free air
800 m
3
/hr
Fan spigot diameter
150mm
Width
900mm
Depth
292mm
Height
280mm
Supply Voltage:
230V~ 50Hz
Power input: Fan
275W
Lighting: Natural White LED:
12V, 2.6W
Light Quantity
2
Total power:
281W
Protective Fuse Sizes for Electrical Supply
3A
CAUTION
To minimise the risk of fire, all instructions relating
to cleaning the grease filters and removing grease
deposits must be adhered to.
Pushbutton Functions
(for models with pushbutton controls)
The extractor controller automatically switches off
the appliance if there has been no operator action
for 4 hours.
After 30 hours accumulated running GREASE
FILTER CLEANING will be signalled by all 6
indicators flashing. Reset by pressing Push-button
FAN OFF (delay).
Lights ON/OFF
Motor ON - SPEED 1
Motor OFF
Motor ON – TIMED INTENSIVE MODE
(Reverts automatically to speed 3 after 5 minutes)
Motor ON - SPEED 3
Maximum Speed for Normal Use
Motor ON - SPEED 2
Motor RUN ON TIMER
(OFF after 10 minutes to clear fumes)
For more detailed specification and energy