5.  OPERATING INSTRUCTIONS 

 

Switch on the power at the fused spur. 

 

The extractor has 6 pushbuttons, which illuminated when 
pressed. Their functions are described below: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

6.  MAINTENANCE 

Regular  maintenance  is  essential  to  ensure  good 
performance and long-life. 

 

To  maintain  the  immaculate  appearance  of  the  extractor, 
and  to  minimise  fire  risk,  ensure  that  grease  deposits  on 
the  extractor  surfaces  are  kept  to  a  minimum  by  regular 
cleaning. 

To clean the stainless steel surfaces of the extractor, use a 
soft cloth and a suitable cleaning agent, such as a specially 
produced stainless  steel  cleaner  or  washing  up  detergent 
and warm water. 

Painted  surfaces  should  be  cleaned  using  a  soft  cloth, 
detergent and warm water. 

Glass  surfaces  should  be  cleaned  with  a  suitable  glass 
cleaning agent. 

 

Do not use abrasive cleaning materials or products. 

 

Do  not  use  bleach  based  cleaning  materials  or 
products. 

 

Clean  the  grease  filters  in  a  dishwasher  or  by  hand-
washing  in  hot  water  and  detergent  every  2  months  - 
sooner  if  the  extractor  is  used  extensively  and  filters 
become grease laden. 

  Whilst  you  can  expect  years  of  service  from  mesh 

grease  filters,  they  are  considered  a  consumable  item 
and  may  deteriorate  over  time  and  need  replacement, 
particularly  when  cleaned  in  a  dishwasher.  For 
dishwasher  users  adhering  to  a  2  monthly  cleaning 
interval we recommend grease filter replacement every 
5 years to maintain optimum performance, even if they 
show  no  visible  signs  of  deterioration.  For  all  users, 
filters  should  be  replaced  whenever  they  exhibit  signs 
of physical wear.  

 

6.1.  Removing the Grease Filters 

The filters have an integrated sprung latch and release 
mechanism. 
Release the latch by pulling the lever and remove the filter. 
The filter is replaced by locating the fixed tabs on the filter into 
corresponding slots in the extractor base and then pushing the 
filter into position with the latch held open. Once the filter is in 
position carefully release the lever, allowing the latch to 
engage. 

6.2.  Replacing Lamps 

The LED lamps are not designed for end user replacement.

 

7.  SPECIFICATIONS 

 

FM900 Built-In Extraction Canopy 

Airflow, nominal in free air 

800 m

3

/hr 

Fan spigot diameter 

150mm 

Width 

900mm 

Depth 

292mm 

Height 

280mm 

Supply Voltage: 

230V~ 50Hz 

Power input: Fan 

275W 

Lighting: Natural White LED: 

12V, 2.6W 

Light Quantity

 

Total power: 

281W 

Protective Fuse Sizes for Electrical Supply 

3A 

 
 

 
 
 
 

CAUTION 

To minimise the risk of fire, all instructions relating 
to cleaning the grease filters and removing grease 

deposits must be adhered to. 

Pushbutton Functions 

(for models with pushbutton controls) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The extractor controller automatically switches off 
the appliance if there has been no operator action 
for 4 hours. 

After  30  hours  accumulated  running  GREASE 
FILTER  CLEANING  will  be  signalled  by  all  6 
indicators  flashing.  Reset  by  pressing  Push-button 
FAN OFF (delay). 

 

Lights ON/OFF 

Motor ON - SPEED 1 

Motor OFF 

Motor ON – TIMED INTENSIVE MODE 

(Reverts automatically to speed 3 after 5 minutes) 

Motor ON - SPEED 3 

Maximum Speed for Normal Use 

Motor ON - SPEED 2 

Motor RUN ON TIMER 

(OFF after 10 minutes to clear fumes) 

For more detailed specification and energy 