
22
Automatic Control
The oil flow supply (heat input) is modulated by the electrical
de-activation of the oil control valve top mechanism in
conjunction with the control thermostat.
At idling temperature, the oil flow modulates down to
minimal rates sufficient to maintain the cooker up to full
temperature, with the indicator or or about the centre of
the silver section of the heat indicator. If not, rotate the
thermostat knob as necessary, but allow at least 12 hours
between re-settings. Once the correct setting has been
found, the cooker will operate automatically to maintain the
cooker at full temperature.
When the cooking loading commences, a fall in oven
temperature will cause the electrical activation of the oil
valve top and subsequent increase in oil flow to a high fire
condition, until recovery to its idling temperature is allowed.
Electrical Power Failure
Despite the loss of electrical power, normal cooking
temperatures can still be obtained, but control must be
manual only.
Method: Holding the actuating lever on the top of the oil
control valve, push it to left and engage it in the ntoch of the
cover. Electrical thermostat control will not be possible until
the actuating lever is dis-engaged.
To Extinguish the Oil Burner
To completely extinguish the oil burner. Turn control knob
fully clockwise to ‘O’ position, and isolate the electrical supply
from the cooker.
If the cooker is being left out of use for more than a few hours
or if the fuel supply has run out, turn off the valves on the oil
feed line from the storage tank.
User’s instructions
Hand the User Guide & Installation Instructions to the User
for retention and instruct the user in the safe operation of the
appliance.
Advise the User of the precautions necessary to prevent
damage to the Domestic Hot Water system and to the
building in the event of the Domestic Hot Water system
remaining inoperative during frost conditions.
Finally, advise the User that, for continued efficient and safe
operation of the appliance it is important that adequate
servicing is carried out at regular intervals recommended by
the AGA Distributor.
Содержание OC
Страница 2: ......
Страница 4: ......
Страница 28: ...Notes 41...
Страница 29: ...Notes 42...
Страница 30: ...Notes 43...
Страница 31: ...Notes 44...