IMPORTANT NOTES

Now that your AGA Solid Fuel Stove is installed and no doubt you are looking forward to many comforts it will
provide, we would like to give you some tips on how to get the best results from your stove.

1.  We would like if you could take some time to read the operating instructions/hints, which we are confident,

will be of great benefit to you.

2.  Do not burn fuel with a high moisture content, such as a damp or unseasoned timber.  This will only result

in a build up of tar in the stove and in the chimney.

3.  Clean the flue-ways of the stove weekly and ensure that there are no blockages.   Check flueways before

lighting especially after a shut down period. Please refer to manual for instructions.

4.  Before loading fresh fuel into the firebox, riddle fully to remove all ashes, this will allow better and cleaner

burning.  See Re-Fuelling Section. 

5.  Never allow a build up of ashes in the ash pan, as this will cause the grate to burn out prematurely.  Empty

the ashpan when re –fuelling.

6.  Allow adequate air ventilation to ensure plenty of air for combustion.

7.  Do not use as an incinerator burning rubbish/household waste.

8.  Do not leave ash door open for long periods as this will over heat the unit causing unnecessary damage. 

Close the ash door between removing and replacing the ashpan.

9.  Clean the chimney at least twice a year.

10.  Burning soft fuels such as timber or peat will stain the glass. Regular cleaning will prevent permanent 

staining.  Clean with soapy water when cool.

11.  Keep all combustible materials a safe distance away from unit, please consult manual for clearance to com-

bustibles table.

12. For safety reasons never leave children or the elderly unaccompanied while stove is in use. Use a fire 

guard.

13.  Avoid contact with the appliance when in use as stove reaches very high operating temperatures.

14. This appliance should be regularly maintained by a competent service engineer. 

Use only replacement parts recommended by AGA.  Making unauthorised modifications, or using unauthorised
parts will invalidate your guarantee and may cause damage or injury.

FUEL CALORIFIC VALUES - SOLID FUELS

Anthracite 25-50mm

C.V.:  8.2kW/Kg 

14,000 BTUs/lb

House Coal 25-75mm  

C.V.:  7.2kW/Kg 

12,000 BTUs/lb

Timber - Firebox size

C.V.:  5.0kW/Kg 

8,600 BTUs/lb

Peat Briquettes

C.V.:  4.8kW/Kg

8,300 BTUs/lb

8

IMPORTANT: [SENO PAINTED STOVES ONLY] 

AN ODOUR WILL EMIT FROM STOVE ON FIRST FIRING, WHEN FIRE REACHES MAXIMUM 
TEMPERATURE OVER A NUMBER OF HOURS THIS ODOUR WILL SUBSIDE. 
IT IS BEST ADVISED TO OPEN WINDOWS DURING THIS PERIOD.  

THIS ODOUR IS UNPLEASANT BUT NOT TOXIC. YOU MAY WISH TO VACATE THE ROOM WHILE THE
PAINT CURES. 

Содержание Berrington

Страница 1: ...sons should be supervised at all times and should not be allowed to touch the hot working sur faces while in use or until the appliance has thoroughly cooled PLEASE READ THESE INSTRUCTIONS CAREFULLY B...

Страница 2: ...onnection 5 10 Location 5 11 Installation Clearances 5 12 Floor Protection 5 13 Technical Data 6 14 Specification 6 15 Operating Instructions 7 17 Primary Air Control 7 16 Low Slumber Burn 7 18 Recomm...

Страница 3: ...petent Persons can be found on their website at www hetas co uk GENERAL When installing operating and maintaining your Berrington Stove respect basic standards of fire safety Read these instructions c...

Страница 4: ...itreous enamelled steel complying with BS 6999 1989 Flue pipes with spigot and socket joints should be fit ted with the socket uppermost CHIMNEY The stove is a radiant room heater and must be con nect...

Страница 5: ...is appliance is rated at less than 9kW It is imper ative that there is sufficient air supply to the stove in order to support correct combustion The air supply to this appliance must comply with B S 8...

Страница 6: ...ustible material From the front 910 mm From the back 800 mm From the sides 800 mm From the flue pipe 910 mm It is recommended that this appliance is sited next to and on a non combustible surface A mi...

Страница 7: ...ation SPECIFICATION TECHNICAL DATA Nominal Heat Output Wood Logs 8 2kW Solid Mineral Fuel 8 5kW Typical refuelling intervals to obtain nominal outputs 1 5 hours wood 4 hours solid mineral fuel Flue Ou...

Страница 8: ...sults Wood logs up to 400mm long are suitable All fuels should be stored under cover and kept as dry as possible prior to use Do not use fuels with a coke ingredient as this may cause the grate to ove...

Страница 9: ...t causing unnecessary damage Close the ash door between removing and replacing the ashpan 9 Clean the chimney at least twice a year 10 Burning soft fuels such as timber or peat will stain the glass Re...

Страница 10: ...the fire door and add more kindling of a larger size to sustain the fire Close the firedoor Do not operate this appliance with the firedoor open 8 Never use inflammable liquid i e gasoline petrol para...

Страница 11: ...r been damaged Replace the hob before relight ing the fire TO REPLACE DAMAGED GRATE OR GRATE BAR Remove the front brick the back brick all the left hand side bricks and both small right side bricks fr...

Страница 12: ...n observe the following tips 1 Wipe over daily with a soapy damp cloth followed by a polish with a clean dry duster 2 For stubborn deposits a soap impregnated pad can be carefully used on the vitreous...

Страница 13: ...sting 23 External Air Wash Casting 24 Inner Top 25 Air Control Stat Knob Black 26 Coil Spring Handle 27 M8 X 100 Spindle 28 Nylon Cap Washer 29 Handle End Cap 30 Aga Badge 31 Driven Rocker Bar 32 Idle...

Страница 14: ...Rev 005 DP110214 Ref N00401AXX Aga Station Road Ketley Telford Shropshire TF1 5AQ UK 13...

Отзывы: