AG SPRAY BRONZE15 Скачать руководство пользователя страница 2

Page 2 

 

IMPORTANT: 

Remove tank lid and be sure the tank is 

clean and free of any foreign material. Rinse tank out of 

any tank residue before filling with water to test. 

 

Testing the Sprayer 

NOTE: It is important that you test your sprayer for leakage and 

proper spray patters with plain water before chemical applica-

tion is attempted. This will also give you the opportunity to  

familiarize yourself with the operation of the sprayer. 

 

Conditions of weather and terrain must be considered when setting 

the sprayer. Do not spray on windy days. Protective clothing must be 

worn in some cases

 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the 

strainer and to the pump. The pump forces the solution under pres-

sure to the handgun. 

 

Connect the lead wire to a fully charged 12 volt battery. You may use 

either a stand-alone battery or the battery on your towing vehicle. 

The lead wire has an On/Off switch to activate the pump. “-” is on 

and “O” is off. 

 

Fill the tank part way with water and then add the desired amount of 

chemical to be sprayed. Finish filling tank to proper level. Turn the 

pump on and by depressing the “-” side of the rocker switch. The 

pump is equipped with a pressure switch that is pre-set at the factory 

to shut the pump off when all discharges are closed. 

 

The pump will turn back on when the handgun lever is squeezed to 

spray. 

 

 

Activate the handgun by squeezing the handle lever 

 

Rotating the adjustable nozzle tip on the handgun will change 
the tip pattern from a straight stream to a cone pattern (finer 

mist) 

 

Maintenance During/After Spraying 

Periodically check the strainer and clean the screen on your intake 

line. 

 

Proper care and maintenance will prolong the life of your sprayer. 

 

After use, drain the tank and store or dispose of chemical properly. 

Fill the sprayer half way with clean water. Start the pump and allow 

the water to pump through the entire plumbing system and nozzles. 

Drain and then refill half full, add the recommended amount of a 

good quality tank cleaner, such as FIMCO Tank Neutralizer and 

Cleaner. (If no tank cleaner is available, you may substitute dish 

soap for this step, about 1-2 oz. per gallon).  Turn pump on and cir-

culate through system for 15 minutes and then spray out through 

handgun nozzle. Refill sprayer half way with clean water and repeat. 

Follow the chemical manufacturer’s disposal instructions of all wash 

or rinsing water.  

If handgun nozzle needs cleaning, remove from the sprayer and soak 

in warm soapy water. Clean with a soft bristled brush or toothpick if 

necessary. Never use a metal object. Even the slightest damage can 

change the flow rate and spray distribution. Water rinse and dry the 

tips before storing. 

 

WARNING: 

Some chemicals will damage the pump valves if 

allowed to soak untreated for a length of time! ALWAYS flush 

the pump as instructed after each  use. DO NOT allow chemicals 

to sit in the pump for extended times of idleness. Follow the 

chemical manufacturer’s instructions on disposal of all waste 

water from the sprayer.

 

 

Winter Storage 

Prepare the sprayer for end-of-season storage by running RV anti-

freeze through the system. This will keep internal parts lubricated, 

protect against corrosion and keep the unit from freezing. 

Note: RV 

antifreeze is non-toxic and biodegradable and generally safer for the 

environment than automotive antifreeze.

 

Before storing your sprayer for winter or long term storage, thorough-

ly clean and drain it as much as possible. Then pour enough pink RV 

antifreeze into the tank so that when the pump is turned on you can 

pump the antifreeze throughout the entire plumbing system, including 

the bypass. Make sure to operate the handgun until you see pink 

fluid spraying from the nozzle. Leave any remaining antifreeze in the 

tank. Before your next usage, rinse the antifreeze from the sprayer 

with clean water. 

It is nearly impossible to drain all of the water from the sprayer and 

any trapped water can freeze in cold weather and damage parts of 

the sprayer. Pumping the antifreeze through the system will displace 

the water and help prevent this damage. 

 

Removing from storage: drain the antifreeze. Fill the tank with fresh 

water and run through the system. Dispose of antifreeze and flush 

water properly. 

Содержание BRONZE15

Страница 1: ...anufacturer or workmanship defects for one year from date of purchase for home owner usage and 90 days for commercial usage For technical assistance visit our website www agspray com or call Toll Free to one of the above phone numbers Our Technical Support Representatives will be happy to help you To obtain prompt efficient service always remember to give the following information Correct Part Des...

Страница 2: ...ood quality tank cleaner such as FIMCO Tank Neutralizer and Cleaner If no tank cleaner is available you may substitute dish soap for this step about 1 2 oz per gallon Turn pump on and cir culate through system for 15 minutes and then spray out through handgun nozzle Refill sprayer half way with clean water and repeat Follow the chemical manufacturer s disposal instructions of all wash or rinsing w...

Страница 3: ...e on position Disconnect the wires off of switch assembly and short them out If your pump runs when you do this your switch assembly will need to be replaced Check the fuse if applicable Check for low voltage at the power supply Pump does not prime Check for air leaks in supply line Check for debris in the valve assembly Check for defective valve assembly Check for clogged strainer filter Check fo...

Страница 4: ...r using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing the problem If still not responsive use a voltmeter or electrical tester to make sure you are getting power to the head of the pump as it could possibly be something in one of the wires or even the lead wire assembly may need to be replaced Warning It is NOT recomm...

Страница 5: ...Page 5 Exploded View Parts List BRONZE15 5302844 Intake Sub Assembly ...

Страница 6: ...u must 1 provide written notice to Ag Spray Equipment of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes neces sary at the following address Ag Spray Equipment 800 Stevens Port Drive Suite DD836 Dakota Dunes SD 57049 and 2 make the Equipment available to Ag Spray Equipment or an authorized dealer within a reasonable period of ...

Отзывы: