Page 3
Technical Specifications
•
65 or 105 Gallon Corrosion
-
Resistant Polyethylene
Tank
•
ProSeries
22”
HP Long Range Ergonomic Handgun
•
25 Ft. Handgun Hose
•
27 Ft. Max. Vertical Throw, 38 Ft. Horizontal Throw
•
Molded
-
In Tank Baffle w/Sloped Floor
•
Molded
-
In Outlet Fitting for Complete Cleanout
•
Electric or Manual Valves
•
Manual has 3
-
Section Control Swing Arm
w/Position Detents
•
Tank Agitator
The PROFESSIONAL SERIES is designed with many features to make operation more user friendly with years of
trouble free use.
Assembly Instructions
The sprayer is assembled already at the factory. The only assembly you will need to do is attaching optional boom or
hose reel when purchased.
Read the operating instructions and then run the sprayer using only water for testing. When everything tests all right, add
the desired chemical mixture and water combination and start the spraying operation.
IMPORTANT:
Remove tank lid and be sure the tank is clean and free of any foreign material. Rinse tank out of any tank
residue before filling with water to test.
Testing the Sprayer/Operation
NOTE:
It is important to test this sprayer for leakage and proper spray patterns with plain water before chemical application is
attempted. This will also give you the opportunity to familiarize yourself with the operation of the sprayer, without the pos-
sibility of losing any expensive chemicals.
1.
Fill the tank about 1/2 full with plain water.
Only fill the tank with what you
’
re going to spray in a day, never leave chemicals sit in tank.
2.
Open the valve in the suction line and allow water to flow to the pump. The valve is located at this point to enable the
strainer to be taken apart for cleaning, while solution remains in the tank.
CAUTION:
Always be sure that the water (or solution) has reached the pump before starting your sprayer. If the pump is
allowed to run dry, serious damage to the pump will result. Do not run your sprayer with the spray nozzle line closed
AND the bypass line closed. Doing this will damage the pump.
3.
It is always best to start the sprayer at little or no pressure. Opening of the bypass line will decrease pressure and
closing it will increase pressure.
The bypass line is the
“
pressure control
”
for the entire plumbing system. The more it is open, the lower your line pres-
sure. Almost fully closed provides maximum pressure to your boom and/or spray nozzle.
NEVER run your system with
this valve 100% closed
.
4.
You may now start the sprayer engine following the engine manufacturers instructions. Let the sprayer run at low
pressure until water has reached the spray nozzle and all air has been purged from the system.
5.
The pressure should now be increased to 15
-
57 PSI. Operate the sprayer at this increased pressure for 3 to 5
minutes, thoroughly testing the unit before adding chemicals.
When everything tests all right (no leaks and good pressure), add the desired chemicals to the mixture and water combi-
nation and start your spraying operation. Adjust the pressure and spray as you did in the testing procedure. The sprayer
should now be ready to use.
(Continued next Page)
OPTIONS
•
50’
Manual Hose Reel w/180° Swivel
•
Booms: Traditional
13’
to
28’
or Boomless
40’
Coverage
IMPORTANT REMINDER:
Add proper oil to the engine crankcase and gasoline to the gas tank. Refer to the engine manual for the correct type
and amount.