OPERATION 

 
 
 

A. PROZONE PZ7 SERIES OZONE GENERATOR OPERATION 

 

The Prozone system works when air is drawn across a high-energy vacuum ultraviolet (VUV) lamp, converting some air to ozone.  A bypass venturi system takes water directly 
after the circulation pump (highest pressure point), bypasses part of the water flow past filters, heater, etc. through a venturi injector, through contact tubing and then returns the 
water back to the pool return line. The system is installed on the return water line and operates during regular filtration cycles.  It is operated automatically by wiring the Prozone 
system directly to the circulation pump.  A check valve is employed to prevent water back up in the event of system failure.  The system should be run a minimum of 12 hours per 
day. For best water quality 24 hour circulation/ozonation is recommended. 

 

B. RECOMMENDED WATER CHEMISTRY AND POOL CARE 

 

    

pH 

- 7.2 to 7.6.  Ozone is pH neutral and will not cause the pH value of the water to fluctuate.  

 
    

Sanitizers

 - A chlorine level of .5 ppm to 1 ppm is recommended.  

 
    

Shock 

- Non-lithium-based material such as Calcium Hypochlorite or Sodium Hypochlorite, etc. 

 
The use of other chemicals is not usually required, and they could react with the ozone causing cloudy water. 
 

Brush pool regularly

 so that algae, spores, etc can be oxidized, as ozonation occurs in the return line. 

 
 
  

 

 

 

 

             

TROUBLESHOOTING GUIDE 

 

 

PROBLEM 

PROBABLE CAUSE 

REMEDY 

No light from Prozone unit 

Loose wiring 
No power to unit  
 
Defective lamp or other internal component 

Check all wiring connections 
Voltage compatibility  
Check power source  
Return unit to dealer  

No bubbles from injector 

Excessive back pressure at pool return 
 
Filter not working 

Check for restrictions at pool wall returns  
 
Check filter 

Water in Ozone Generator 

Check valve failure 
 
High back pressure on return line 

Verify check valve in venturi is operating properly

  

 

Check for restrictions in line 

Cloudy water; foamy water; scum 

Water chemistry out of balance 
Total Dissolved Solids (TDS) level too high 
  
Filter not working 

 

Check readings and balance accordingly  
Refer to dealer for proper water testing  
 
Clean or replace filter 

 

 

 

 

 

 

 

NOTE:

 Cloudy water may occur when the ozone generator is started.  Filter and backwash as necessary. 

 

SPECIAL NOTE:

 In some instances when the pump and filter are below the water level in the pool, pump prime may be lost when the filtration system is powered down.  (This 

can be caused by the air draw through the injector).  One method of correcting this is to install an electrically operated, normally closed solenoid valve in the air line between the 
Ozonator and the Venturi Injector.  Cut the 1/4 inch hose between the Ozonator and the Injector and install the solenoid valve using compatible fittings).  The voltage rating of the 
valve should be according to the locally available voltage.   If there is a controller that turns the pool circulation pump on/off, the solenoid valve should be connected to this.  If 
there is a spare set of relay contacts in the controller, connect the solenoid's power leads to these relay contacts.  If there is no extra set of relay contacts available, connect the 
solenoid power leads to the same terminal as the circulation pump.  The solenoid valve should close when the circulation pump turns off or if power is lost. 

 
 
 
 
 
 
 

Отзывы: